Geri Dön

Titanyum implant dayanakları üzerine hazırlanmış eklemelı yöntemlerle üretilmiş üç üniteli daimi kron reçinelerinin kırılma dayanımlarının karşılaştırılması

Comparison of fracture resistance of three-unit permanent crown resins fabricated by additive manufacturing methods on titanium implant abutments

  1. Tez No: 1015285
  2. Yazar: SENA KOCA
  3. Danışmanlar: DR. ÖĞR. ÜYESİ RECEP TÜRKEN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: dental implant, eklemeli üretim, frezeleme, kırılma dayanımı, nanoseramik reçine, PMMA, additive manufacturing, dental implant, fracture resistance, milling, nanoceramic resin, PMMA
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Ordu Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET TİTANYUM İMPLANT DAYANAKLARI ÜZERİNE HAZIRLANMIŞ EKLEMELİ YÖNTEMLERLE ÜRETİLMİŞ ÜÇ ÜNİTELİ DAİMİ KRON REÇİNELERİNİN KIRILMA DAYANIMLARININ KARŞILAŞTIRILMASI Amaç: Titanyum implant dayanakları üzerine 3B baskı ile üretilen nanoseramik dolgulu fotopolimer reçine (SprintRay OnX Tough 2) ve CAD/CAM frezeleme ile üretilen PMMA bloklardan elde edilen 3 üniteli daimi kron restorasyonların kırılma dayanımlarını; kron uzunluğu ve implant açılanması değişkenleri açısından karşılaştırmaktır. Gereç ve Yöntem: Materyal (ONX2, PMMA), kron uzunluğu (normal/uzun) ve implant açılanması (0°/30°) değişkenlerine göre 8 grupta toplam 80 örnek (n=10/grup) kullanılmıştır. NucleOSS titanyum implant sistemleri üzerine tasarlanan restorasyonlar, termal siklus sonrası universal test cihazıyla (AGX-S; Shimadzu) kırılma dayanımı testine tabi tutulmuş; değerler Newton cinsinden kaydedilmiştir. Veriler Three-Way ANOVA ve Tamhane post-hoc testi ile, kırık yüzeyleri SEM ile incelenmiştir (p<0,05). Bulgular: PMMA grubunun ortalama kırılma dayanımı (1848,8 N), ONX2 grubuna (1574,9 N) göre anlamlı biçimde yüksek bulunmuştur (p<0,001). Uzun kron boyuna sahip gruplar (2038,2 N), normal boy gruplara (1385,6 N) kıyasla anlamlı üstünlük sergilemiştir (p<0,001). İmplant açılanmasının kırılma dayanımı üzerinde anlamlı bir etkisi gözlemlenmemiştir (p>0,05). Sonuç: CAD/CAM frezeleme ile üretilen PMMA restorasyonlar, 3B baskı ile üretilen nanoseramik reçine restorasyonlara göre daha yüksek kırılma dayanımı sergilemiştir. Kron uzunluğunun artması her iki grupta da dayanımı olumlu etkilerken, implant açılanması belirleyici bir faktör olmamıştır.

Özet (Çeviri)

ABSTRACT COMPARİSON OF FRACTURE RESİSTANCE OF THREE-UNİT PERMANENT CROWN RESİNS FABRİCATED BY ADDİTİVE MANUFACTURİNG METHODS ON TİTANİUM IMPLANT ABUTMENTS Aim: To compare the fracture resistance of 3-unit permanent crown restorations fabricated from nanoceramic-filled photopolymer resin (SprintRay OnX Tough 2) via 3D printing and from PMMA blocks via CAD/CAM milling on titanium implant abutments, considering crown length and implant angulation. Material and Method: Eighty specimens were divided into 8 groups (n=10) based on material (ONX2, PMMA), crown length (normal, long), and implant angulation (0°, 30°). Restorations were designed on NucleOSS titanium implant systems and fabricated accordingly. Following thermocycling, fracture resistance was tested using a universal testing machine (AGX-S; Shimadzu) and recorded in Newtons. Data were analyzed with three-way ANOVA and Tamhane post-hoc test; fracture surfaces were examined by SEM (p<0.05). Results: The PMMA group exhibited significantly higher mean fracture resistance (1848.8 N) than the ONX2 group (1574.9 N) (p<0.001). Long crown groups (2038.2 N) significantly outperformed normal length groups (1385.6 N) (p<0.001). Implant angulation had no significant effect on fracture resistance (p>0.05). Fracture patterns differed significantly by crown length but not by material or angulation. Conclusions: CAD/CAM-milled PMMA restorations demonstrated superior fracture resistance over 3D-printed nanoceramic resin restorations. Increased crown length positively influenced fracture resistance in both groups, while implant angulation was not a determining factor.

Benzer Tezler

  1. Üç farklı dayanak materyalinin dinamik yükleme sonucunda implant-dayanak birleşiminde meydana gelen değişiklikler ve dayanıklılık yönünden incelenmesi

    Comparison of changes in the implant-abutment interface after dynamic loading and strength of three different abutment materials

    BULEM YÜZÜGÜLLÜ

    Doktora

    Türkçe

    Türkçe

    2003

    Diş HekimliğiHacettepe Üniversitesi

    Protez Ana Bilim Dalı

    PROF. DR. MEHMET AVCI

  2. CAD/CAM sistemleri kullanılarak üretilen üç üyeli implant destekli sabit bölümlü protez altyapılarının marjinal ve internal uyumlarının karşılaştırılması

    Comparison of marginal and internal adaptation in the frameworks of three-unit implant supported fixed partial denture produced by using CAD/CAM systems

    ÖZLEM KAYIKÇI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiRecep Tayyip Erdoğan Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. SABİT MELİH ATEŞ

  3. Farklı materyallerle hazırlanmış içbükey çıkış profiline sahip bireysel dayanakların kırılma dayanımları ve yük altında kuvvet dağılımlarının araştırılması

    Evaluation of fracture strength and stress distribution of convex shaped individual abutments under load fabricated from different materials

    FATMA ERŞİL

    Doktora

    Türkçe

    Türkçe

    2019

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. MEHMET SONUGELEN

  4. Ti6Al4V alaşımına uygulanan farklı yüzey modifikasyonlarının EPD yöntemi ile üretilen hidroksiapatit kaplamalara etkisinin incelenmesi

    Investigation of the effect of different surface modifications applied to Ti6Al4V alloy on hydroxyapatite coatings produced by EPD method

    ALPEREN KIZILÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Metalurji MühendisliğiManisa Celal Bayar Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET TÜRK

  5. İmplantüstü sabit bölümlü protezlerde kullanılan seramik implant dayanaklarının sonlu elemanlar yöntemi ile incelenmesi

    The investigation of the ceramic implant abutments used in implant supported fixed dentures by finite element method

    HÜSEYİN EMİR YÜZBAŞIOĞLU

    Doktora

    Türkçe

    Türkçe

    2006

    Diş HekimliğiOndokuz Mayıs Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Y.DOÇ.DR. DUYGU SARAÇ