Geri Dön

Kompozit overley materyallerin aşınma ve kırılma dayanımlarının değerlendirilmesi

Evaluation of wear and fracture resistance of composite overlay materials

  1. Tez No: 1024444
  2. Yazar: HANDE SARAÇ DİLBER
  3. Danışmanlar: DOÇ. DR. TUĞBA SERİN KALAY
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: 3B baskı, Aşınma, Eklemeli üretim, Kompozit rezin, Kırılma dayanımı, Overley, 3D printing, Wear, Additive manufacturing, Composite resin, Fracture resistance, Overlay
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Karadeniz Teknik Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Restoratif Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Kompozit Overley Materyallerin Aşınma ve Kırılma Dayanımlarının Değerlendirilmesi Bu çalışmanın amacı, farklı materyal/yöntemlerle üretilmiş (direkt, indirekt, 3B baskı, CAD/CAM) kompozit overley restorasyonların termo-mekanik yaşlandırma sonrası kırılma dayanımlarını ve bu materyallerin aşınma davranışlarını karşılaştırmalı olarak incelemektir. Çalışmada beş farklı güncel kompozit materyal kullanıldı: VS-VarseoSmile Crown Plus (3B hibrit kompozit rezin baskı reçinesi), BC-Brilliant Crios (CAD/CAM kompozit blok), FZ-Filtek Z250 (mikrohibrit direkt kompozit), GP-Gradia Plus (nanohibrit indirekt kompozit) ve GI-G-aenial Universal Injectable (yüksek dolduruculu akışkan kompozit). Aşınma davranışının de-ğerlendirilmesi amacıyla her materyalden 7×12×2 mm boyutlarında örnekler hazırlandı (n:7/grup). Çiğneme simülatörü ile uygulanan termo-mekanik yaşlandırma sonrasında oluşan aşınma yüzeyleri, üç boyutlu optik profilometre ile değerlendirildi (hacim kaybı, maksimum aşınma derinliği ve ortalama maksimum aşınma derinliği parametreleri) ve taramalı elektron mik-roskobu (SEM) ile incelendi. Materyallerin Vickers sertlik ölçümleri, 300 gf yük ve 15 s bekleme süresi kullanılarak gerçekleştirildi. Kırılma dayanımı testi için çürük, kırık veya çatlak içermeyen 42 maksiller premolar diş rastgele altı gruba ayrıldı (n:7); kontrol (C) ve beş materyal grubu (BC, VS, FZ, GP ve GI). Standart overley kavite preparasyonları hazırlandı ve materyale uygun yöntemle kompozit overley restorasyonlar üretildi. Tüm örneklere 240.000 döngü termo-mekanik yaşlandırmaya tabi tutulduktan sonra kırılma dayanımları ölçüldü ve kırık tipleri değerlendirildi. Gruplar arasındaki karşılaştırmalarda tek yönlü ANOVA ve Tukey HSD post hoc testleri, kırık tipi dağılımında ise ki-kare testi kullanıldı. p<0,05 düzeyi istatistiksel olarak anlamlı kabul edildi. Hacim kaybı, maksimum aşınma derinliği, ortalama maksimum aşınma derinliği, sertlik ve kırılma dayanımı değerleri bakımından gruplar arasında istatistiksel olarak anlamlı fark bulundu (p<0,001). Aşınma parametrelerinde en yüksek değerler VarseoSmile Crown Plus grubunda, en düşük değerler ise Brilliant Crios grubunda görüldü. Kırılma dayanımında en yüksek değerler Kontrol ve Brilliant Crios gruplarında, en düşük değer ise VarseoSmile Crown Plus grubunda saptandı. Sertlik değerleri bakımından en yüksek değer Brilliant Crios grubunda, en düşük değer VarseoSmile Crown Plus grubunda elde edildi. Kırık tipi dağılımı açısından gruplar arasında istatistiksel olarak anlamlı fark bulunmadı.

Özet (Çeviri)

ABSTRACT Evaluation of Wear and Fracture Resistance of Composite Overlay Materials The aim of this study was to comparatively evaluate the fracture resistance of composite overlay restorations fabricated using different materials and techniques (direct, indirect, 3D prin-ting, CAD/CAM) after thermo-mechanical aging, as well as the wear resistance of these materials. Five contemporary composite materials were used in this study: VS–VarseoSmile Crown Plus (3D-printed hybrid composite resin), BC–Brilliant Crios (CAD/CAM composite block), FZ–Filtek Z250 (microhybrid direct composite), GP–Gradia Plus (nanohybrid indirect composite), and GI–G-aenial Universal Injectable (highly filled flowable composite). To evaluate wear beha-vior, specimens measuring 7 × 12 × 2 mm were prepared from each material (n: 7/group). Fol-lowing thermo-mechanical aging in a chewing simulator, the resulting wear surfaces were evalua-ted using a three-dimensional optical profilometer in terms of volume loss, maximum wear depth, and mean maximum wear depth and were also examined by scanning electron microscopy (SEM). Vickers hardness measurements were performed under a load of 300 gf with a dwell time of 15 s. For fracture resistance testing, 42 caries-free maxillary premolar teeth without fractures or cracks were randomly divided into six groups (n: 7): one control group (C) and five material groups (BC, VS, FZ, GP, and GI). Standardized overlay cavity preparations were performed, and composite overlay restorations were fabricated using the appropriate technique for each material. After all specimens were subjected to 240,000 cycles of thermo-mechanical aging, their fracture resistance was measured, and failure modes were evaluated. One-way ANOVA and Tukey HSD post hoc tests were used for comparisons among gro-ups, while the chi-square test was used to analyze the distribution of failure modes. The level of statistical significance was set at p<0.05. Statistically significant differences were found among the groups in terms of volume loss, maximum wear depth, mean maximum wear depth, hard-ness, and fracture resistance values (p<0.001). The highest values for wear parameters were ob-served in the VarseoSmile Crown Plus group, whereas the lowest values were observed in the Brilliant Crios group. Regarding fracture resistance, the highest values were recorded in the Cont-rol and Brilliant Crios groups, while the lowest value was found in the VarseoSmile Crown Plus group. In terms of hardness, the highest value was obtained in the Brilliant Crios group, and the lowest value was obtained in the VarseoSmile Crown Plus group. No statistically significant difference was found among the groups in terms of failure mode distribution.

Benzer Tezler

  1. Kısa fiber ile güçlendirilen posterior overlay restorasyonların, kırılma dirençlerinin, farklı kalınlıktaki CAD/CAM restoratif materyalleri ile karşılaştırılması

    Comparison of fracture resistance of short fiber reinforced posterior overlay restorations with different thicknesses CAD/CAM restorative materials

    ALPTEKİN YUSUF KÖK

    Doktora

    Türkçe

    Türkçe

    2025

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SADULLAH ÜÇTAŞLI

  2. Farklı kalınlıklardaki cad/cam hibrit seramik ve kompozit reçine overlaylerin termomekanik yaşlandırma sonrası aşınma dirençlerinin In vitro olarak karşılaştırılması

    In vitro comparison of the wear resistance of cad/cam hybrid ceramic and composite resin overlays of different thicknesses following thermomechanical aging

    BEYZANUR BAYSAL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2026

    Diş HekimliğiMarmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ CEREN KÜÇÜK

    DR. ÖĞR. ÜYESİ NAZLI ZEYNEP AKTAŞ

  3. Porselen, hibrit, kompozit bloklar kullanılarak yapılan sınıf ıı indirekt restorasyonların 1 yıllık klinik performansının değerlendirilmesi

    Evaluation of 1 yearly clinical performance of class ii indirect restorations using porcelain, hybrid, composite blocks

    BURHANETTİN AVCI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiErciyes Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. SOLEY ARSLAN

  4. Porselen, hibrit, kompozit bloklar kullanılarak devital dişlere yapılan sınıf ıı indirekt restorasyonların 1 yıllık klinik performansının değerlendirilmesi

    Evaluation of 1-year clinical performance of class ii indirect restorations using porcelain, hybrid, composite blocks to devital teeth

    MEHMET KARAGÖN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiErciyes Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SOLEY ARSLAN

  5. Dental yapıştırma simanlarının dişeti üzerine sitotoksik etkilerinin üç farklı test yöntem ile in vitro değerlendirilmesi

    In vitro evaluation of the cytotoxic effects of dental luting agents on gingiva with three different test methods

    AYŞE ZÜLAL ORUÇ

    Doktora

    Türkçe

    Türkçe

    2004

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF.DR. AYHAN GÜRBÜZ