Geri Dön

Farklı tip tam seramik kronların uyumlarının in vitro olarak değerlendirilmesi

In vitro evaluation of marginal fit of different all ceramic crowns

  1. Tez No: 163702
  2. Yazar: MÜNİR TOLGA YÜCEL
  3. Danışmanlar: PROF.DR. FİLİZ AYKENT
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2005
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 83

Özet

6.ÖZET S.Ü. Sağlık Bilimleri Enstitüsü Protetik Diş Tedavisi Anabilim Dalı DOKTORA TEZİ/ KONYA-2005 Dt. Münir Tolga YÜCEL Danışman Prof.Dr. Filiz AYKENT FARKLI TİP TAM SERAMİK KRONLARIN MARJİNAL UYUMLARININ IN VITRO OLARAK DEĞERLENDİRİLMESİ Bu çalışmada dört farklı tam seramik sistemden üretilen kronların marjinal uyumlarının in vitro olarak karşılaştırılması amaçlandı. Çalışmada önce maksiller santral diş için tam seramik kron preparasyonunu taklit eden paslanmaz çelikten bir master model hazırlandı. Hazırlanan bu model üzerinden polivinil siloksan ile ölçüler alınarak 80 adet çalışma die'ları elde edildi. Elde edilen die'lar her bir grupta 20 adet olacak şekilde rasgele 4 gruba ayrıldı. İlk olarak 1. gruptaki 20 adet çalışma die'larına üretici firma talimatlarına göre Cerec 3 kronlar hazırlandı. Bu kronlardan ölçü alınarak standardizasyonu sağlamak amacıyla silikon anahtarlar hazırlandı. Daha sonra bu silikon anahtar yardımıyla die'lara sırasıyla In-Ceram, IPS Empress 2 ve Celay kronlar üretici firma talimatlarına göre hazırlandı. Kronların marjinal uyumları bukkal, mezial, lingual ve distal yüzeylerdeki 80 farklı noktada önce kendi çalışma die'lan üzerinde, ardından master model üzerinde simante edilmeksizin Nikon SMZ1500 steromikroskobunda incelendi. Elde edilen marjinal açıklıklara! görüntü analizi, Clemex programında yapıldı. 59Test sonucu elde edilen değerler iki yönlü varyans analizi, tek yönlü varyans analizi ve Tukey HSD istatistiksel analizleri ile değerlendirildi. Çalışma die'lan ve master model üzerindeki ölçümler arasında istatistiksel olarak önemli fark görüldü. İstatistiksel analiz sonucunda çalışma die'ları üzerindeki ölçümlerde en düşük marjinal aralık Celay (21,5 + 4 um) grubunda bulundu. Ardından gelen IPS Empress 2 (29,3+5 um) ve Cerec 3 (33+4 um) örnekler arasında önemli fark bulunmazken en yüksek değerlere In-Ceram grubunda (74,6+10 um) rastlandı. Master model üzerinde yapılan ölçümler sonucu tüm gruplar arasında önemli fark bulunurken, en iyi grup yine Celay (27,8 + 4 um), ardından sırasıyla EPS Empress 2 (41,5+7 um), Cerec 3 (47,4+5 um) ve In-Ceram (94,9+10 um) grupları geldi. Her iki çalışma modelinde de Celay kronlar en iyi marjinal uyumu gösterirken In- Ceram kronlar en kötü marjinal uyumu gösterdiler. Bu sonuçlara göre hem çalışma die'ları hem de master model üzerinde, tüm seramik sistenılerinin marjinal açıklığı, klinik olarak kabul edilebilir maksimum değer olan 120 u'un altında bulundu. 60

Özet (Çeviri)

7. SUMMARY In Vitro Evaluation of Marginal Fit of Different All Ceramic Crowns The purpose of this in vitro study was to compare the marginal fit of crowns fabricated with 4 different all-ceramic systems. A standardized all-ceramic preparation was made from stainless steel. Eighty gypsum dies were duplicated from this master steel die using polyvinyl siloxane impression material and randomly divided into 4 groups of 20 each. At first, Cerec 3 crowns were made according to manufacturer's instructions. Silicon key was prepared from these crowns. And then In-Ceram, IPS Empress 2 and Celay crowns were fabricated on dies of each group respectively using this silicon key. The marginal gap of crowns were evaluated four surfaces of a crown at 80 different points without cementation on the gypsum dies and then master steel die with Nikon SMZ 1500 stereomicroscope and Clemex image analysis programme. The marginal opening value of each crown was obtained by calculated mean and standard deviations of 80 measurements. Two-way analysis of variance, One-way analysis of variance and Tukey HSD tests were used to evaluate the data. A significant difference was found among the marginal gap of crowns measured on the master steel die and gypsum dies (p

Benzer Tezler

  1. İki farklı tam seramik kor materyalinin baskı dayanıklılığı ve marjinal uyumu üzerine farklı marjinal dizayn ve taper açılarının etkisi

    The effect of different margin designs and taper angles on the compressive strength and marginal fit of two different all ceramic cores

    H.NALAN BOZOĞULLARI

    Doktora

    Türkçe

    Türkçe

    2007

    Diş HekimliğiSelçuk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF.DR. ÖZGÜR İNAN

  2. Kopya freze tekniği ile elde edilen tam seramik feldspatik kuronların yapımında kullanılan çeşitli maket materyallerinin kenar ve iç uyuma etkisinin incelenmesi

    Evaluation of the effect of several modelling resins to marginal and internal fit, which were used for construction of full ceramic feldspathic crowns prepared with the copy milling technique

    BİRİZ BAŞARAN ORDUKAYA

    Doktora

    Türkçe

    Türkçe

    2004

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF.DR. ÇETİN SEVÜK

  3. Farklı fiber post sistemlerinin mikrosızıntı ve kırılma dayanımlarının in vitro olarak değerlendirilmesi

    In vitro ınvestigation of microleakage and fracture strength of different fiber post systems

    TUĞRUL SARI

    Doktora

    Türkçe

    Türkçe

    2007

    Diş HekimliğiSelçuk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Y.DOÇ.DR. ATİLLA GÖKHAN ÖZYEŞİL

  4. Farklı kor seramiklerin ışık geçirgenliğinin incelenmesi

    Examination of the light transmission of different ceramic cores

    ÖZLEM CEYLAN

    Doktora

    Türkçe

    Türkçe

    2007

    Diş HekimliğiSelçuk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF.DR. FİLİZ AYKENT

  5. Zirkonya korların değişik yöntemlerle aşındırılması sırasında meydana gelen ısı değişikliklerinin değerlendirilmesi

    Evaluation of temperature changes of zirconia frameworks while grinding with different techniques

    ÖZGECAN KÜÇÜKKURT

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Diş HekimliğiYeditepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ENDER KAZAZOĞLU