Yüz defektlerinde kullanılabilecek farklı implant tasarımlarının kemikte oluşturduğu gerilmelerinin sonlu elemanlar analizi yöntemi ile değerlendirilmesi

A finite element stress analysis of bone around a different implant design that can be used in facial defects

  1. Tez No: 165770
  2. Yazar: BANU KARAYAZGAN
  3. Danışmanlar: DOÇ. DR. GÜLÜMSER EVLİOĞLU
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Kraniyofasıyal implant, sonlu elemanlar analizi, biyomekanik, Von Mises, tasarım, üç boyutlu modelleme 141, Craniofacial implant, finite element method, biomechanics, Von Mises, design, three dimensional modeling 144
  7. Yıl: 2005
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 183

Özet

Yüz defektli hastaların protetik rehabilitasyonunda kraniyofasiyal implant sistemleri son yıllarda başarılı sonuçlar vermektedir. Tutuculuğu diğer yöntemlere nazaran daha güvenilir olan bu implant sistemlerinin kullanım sahası çoğu zaman yüz bölgesinde yeterli kemik hacimlerinin mevcut olmaması sebebiyle ciddi bir şekilde kısıtlanır. Araştırmamızda mevcut sistemlere alternatif olarak, yetersiz kemik hacimlerinde daha yaygın olarak kullanılabilecek yeni bir implant sistemi sanal ortamda tasarlandı. Bu implant tasarımında, çeşitli yükler altında kemikte meydana gelen stres dağılımları sonlu elemanlar gerilme analizi yöntemi ile değerlendirildi. Çalışmanın birinci aşamasında mevcut kraniyofasiyal implant sistemi ile önerilen implant tasarımı farklı konfigürasyonlara sahip düz yüzeyli kemikler üzerinde kıyaslandı. Kemik ve implant modellemesi, kuvvetlerin uygulanması ve sonuçların elde edilmesi Ansys 7.0 paket programı (Swanson Analysis Systems,Inc.,Houston,TX,USA) aracılığıyla gerçekleştirildi. İkinci aşamada ise kafatasmdan alman bilgisayarlı tomografi kesitleri Materialise Mimics programı kullanılarak üç boyutlu hale getirildi. Ansys programında önceden çizilmiş olan implant tasarımı üç boyutlu kafatası modelinde belirlenen iki farklı bölgeye yerleştirildi. Bu iki bölgenin seçiminde mevcut implantlarm uygulanamadığı bölgeler olmasma dikkat edildi. Bunu takiben, implanta uygulanan kuvvetler sonucunda meydana gelen stresler mevcut literatür verileriyle kıyaslandı ve uygunluğu tartışıldı. Yapılan incelemede en yüksek Von Mises değeri kortikal kemiğin 0,5 mm olduğu 3 mm kalınlığındaki kemik hacminde 2x2,5 mm vida boyutlu implant tasarımı çevresinde 6.696 Mpa olarak tespit edildi. En düşük gerilme ise 3 mm kortikal kemikte ve 1x2,5 mm vida boyutlu implant tasarımında 2.73 8Mpa olarak bulundu. 1x1 mm. vida boyutlu implant tasarımı vertikal kuvvetler karşısında kortikal kemik tabakasında orta dereceli bir gerilim oluştursa da bu kemik bölgesinde bir alternatif olarak göz önünde bulundurulabilir. Tasarlanmış implantlardan 1x1.5mm, lx2mm, 2x2mm ve 1401x2,5mm boyutlu vidalı implant tasarımı mevcut implantların uygulanamayacağı bölgelerde yüz protezlerinin tutuculuğuna destek olmak amacıyla kullanılabilirler.

Özet (Çeviri)

Craniofacial implant systems that have been introduced for the prosthetic rehabilitation of patients with facial defects are considered to be successful approaches. However these more reliable systems are generally compromised with insufficient bone volume in the facial area. In this study, a new craniofacial implant to be widely used in sites with insufficient bone was introduced and designed in a computer based environment. Stress distributions around the bone due to various loads were evaluated with finite element method. In the first stage of this study, a comparison was made between the predicted implant design and a craniofacial implant system which is already present in the market Comparisons were made on plain surfaced bone volume with different configurations. The modeling of the bone and the implant, application of the loads, obtaining the results were performed with Ansys 7.0 Software (Swanson Analysis Systems, Inc., Houston, TX, USA). In the second stage, a three dimensional image was processed with the data derived from CT scans with a software called Materialise Mimics. Implant design that was previously created in the Ansys software was applied on two areas that were considered as insufficient areas for craniofacial implant applications. Stress that occurred as the result of the loads applied on the implant was compared with literature data and appropriateness of it was discussed. 143In this investigation, the highest Von Mises value of 6.696 was obtained in the implant design with 2x2,5 mm screw dimensions in 3 mm bone where cortical part was 0.5 mm. lowest stress occurred as 2.738MPa was observed around the implant design with 1x25 mm screw size in 3 mm compact bone. Even though lxl mm implant produced a mild level of stress in the bone due to vertical loads, it can still be considered as an alternative. Of all the designs, implants with lxl, 5mm, 1x2mm, 2x2mm and 1x2,5mm screw dimensions can be used as supportive retainers in the areas where present craniofacial implants can't be utilized.

Benzer Tezler

  1. Çeneler bölgesinde meydana gelen kemik defektlerinin solvent dehidrate allojen spongiöz kemik greftleri ile tedavisi

    Başlık çevirisi yok

    M. CEMAL AKAY

    Doktora

    Türkçe

    Türkçe

    1998

    Diş HekimliğiEge Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. DR. SEVTAP GÜNBAY

  2. Otojen kemik greftlerinin fiksasyonunda fibrin yapıştırıcı ve n-butil-2-siyanoakrilatın etkilerinin deneysel olarak incelenmesi

    The experimental evaluation of fibrin glue and n-butyl-2-cyanoacrylates effects of fixation at autogenous bone grafts

    BUĞRA SOYGÜDEN

    Doktora

    Türkçe

    Türkçe

    2002

    Diş HekimliğiMarmara Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    DOÇ.DR. BAHAR GÜRSOY

  3. Tavşanda genişletilmiş lateral torasik arter bazlı fasyokutan flebin çok amaçlı kullanımı (deneysel çalışma)

    The versatile use of extended lateral thoracic artery-pedicled fasciocutaneous flap: an experimental study

    MEHMET SAĞIR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    Plastik ve Rekonstrüktif CerrahiSağlık Bakanlığı

    Plastik ve Rekonstrüktif Cerrahi Ana Bilim Dalı

    DOÇ. DR. SAMET VASFİ KUVAT

  4. Ratlarda oluşturulan kritik boyut defektlerinde mecsina hemostopper'ın kemik rejenerasyonu üzerine olan etkisinin histolojik olarak değerlendirilmesi

    Histological evaluation of the effect of mecsina hemostopper on bone regeneration in critical size defects in rats

    PELİN AYDIN

    Doktora

    Türkçe

    Türkçe

    2019

    Diş HekimliğiBaşkent Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. DR. SIDIKA SİNEM AKDENİZ

  5. Capparis spinosa ekstresinin deneysel olarak oluşturulan kemik defektlerinde yeni kemik oluşumuna etkisinin incelenmesi

    The evaluation of Capparis spinosa extract effect on bone defects formed experimentally

    MUSTAFA KIRTAY

    Doktora

    Türkçe

    Türkçe

    2012

    Diş HekimliğiCumhuriyet Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. HASAN YELER