Kolofonun betonarme çeliği korozyonuna etkilerinin tahribatsız elektrokimyasal yöntemlerle incelenmesi

The investigated of colophony on concrete corrosion with electrochemical methods

  1. Tez No: 184593
  2. Yazar: SELDA EMRE ÜNCÜ
  3. Danışmanlar: DOÇ.DR. TÜLİN KIYAK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kimya, İnşaat Mühendisliği, Chemistry, Civil Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2006
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İleri Teknolojiler Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 117

Özet

ivKOLOFONUN BETONARME ÇEL Ğ KOROZYONUNA ETK LER N NTAHR BATSIZ ELEKTROK MYASAL YÖNTEMLERLE NCELENMES(Yüksek Lisans Tezi)Selda EMRE ÜNCÜGAZ ÜN VERS TESFEN B L MLER ENST TÜSÜEkim 2006ÖZETBu çalışmada, boya sanayinde katkı maddesi olarak kullanılan kolofonun, çelikve betonarme çeliği korozyonu üzerindeki etkileri betonarme çeliği korozyonuiçin yeni deneysel yaklaşımlar önerilerek araştırılmıştır.Çalışmada NaCl çözelti ortamlarında kolofon katkılı beton içindeki çelikelektrodun korozyon davranışları araştırılmıştır. Bu bulgular beton kaplamaiçinde olmayan çelik elektrotların farklı pH'larda kolofonlu ve kolofonsuz suluortamlardaki korozyon davranışları ile karşılaştırılmıştır. Elde edilen bulgular,birbirleriyle ve korozyona uğrayan yüzey görüntüleri ile beraberdeğerlendirilmiştir. % 3 tuzlu su içinde bekletilen betonarme örneklerininkorozyon özellikleri, ADP (açık devre potansiyeli), Ei=0 (korozyonpotansiyelleri), EIS (elektrokimyasal empedans spektroskopisi),kronoamperometri, kronoklonometri ve dönüşümlü voltametri tekniklerikullanılarak 71 gün boyunca belirli periyotlarda takip edilmiştir. Uygulanan bufarklı teknikler arasında betonarme korozyonu açısından benzer eğilimleri vesonuçları ortaya çıkaran en uygun deneysel yönler tartışılmıştır.Sonuç olarak kolofonun yapışkan özelliği ile betonun gözeneklerinikapatmasından dolayı su ve çeşitli kimyasalların yapıya girişini ve çeliğedifüzyonunu engelleyerek korozyonu yavaşlatıcı bir etki gösterdiğivbelirlenmiştir. Bununla beraber kolofonun yüzey oksit filminin çözünmesinihızlandırarak, beton içerisindeki çeliğin korozyonunu artırma eğilimindeolduğu da görülmüştür.Bu araştırmalar sırasında, çeşitli çimento tiplerinin betonarme korozyonunaetkisinin açıkça görülebileceği ve birbirini destekleyen elektrokimyasalyöntemler önerilmiştir.Bilim Kodu : 201.1.080Anahtar Kelimeler : Korozyon, Betonarme Korozyonu, KolofonSayfa Adedi : 96Tez Yöneticisi : Doç. Dr. Tülin KIYAK

Özet (Çeviri)

ivTHE INVESTIGATED OF COLOPHONY ON CONCRETE CORROSIONWITH ELECTROCHEMICAL METHODS(M.Sc. Thesis)Selda EMRE ÜNCÜGAZ UNIVERSITYINSTITUTE OF SCIENCE AND TECHNOLOGYOctober 2006ABSTRACTIn this study, the effects of colophony which is used in paint industry asingredient, on the corrosion of concrete and steel were investigated. Thecolophony may have binder and inhibition effect for corrosion in rigid concretestructure. It was thought that the physical performans of concrete may beaffected by using colophony as an additive. Also at this study, novelapproximations and interpretation of experimental data were suggested for theinvestigation of corrosion feature of steel in concrete.By the aim, corrosion properties of concrete prepared by adding 3 % NaCl andvarious amount colophony into the mixing water, and of steel electrode incolophony solutions which contains 0.1 M NaCl at pH=12 ve pH=6 media wereexamined electrochemically. Experimental results were utilized together withsurface morphology. Corrosion properties of concrete samples in the 3 % saltsolution were monitored throughout 71 days in the specified periods by usingOCP (open cycle potential), EIS (electrochemical impedance spectroscopy),cronoamperometry, cronoqulometry and cyclic voltametry techniques.It is observed that the colophony inhibited the corrosion of concrete by means ofbarrying water and various chemicals due to the tapping pores of concrete, andvbut also increase the solubility of surface oxide film to increase very muchcorrosion of steel in concrete.Science Code : 201.1.080Key Words : Corrosion, Concrete Corrosion, ColophonyPage Number : 96Adviser : Doç. Dr. Tülin KIYAK

Benzer Tezler

  1. 17 Ağustos 1999 İzmit depreminin yapılar üzerindeki hasarları ve bu hasarlara korozyonun etkisi

    Damages of 17 August 1999 Izmit earthquake on buldings and effect of corrosion on these damages

    TOLGA ARKOÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    İnşaat MühendisliğiYıldız Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. NİLGÜN AKTAN

  2. Hysteretic response of sub-standard rc columns under high axial stresses and shear demand confined with carbon fiber polymers

    Karbon lifli polimer ile sargılanan standart altı betonarme kolonların yüksek eksenel gerilme ve kesme talebi altında tekrarlı çevrimsel davranışı

    MERVE NUR DEMİR

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    Deprem Mühendisliğiİstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. ALPER İLKİ

  3. Betonarme kirişlerde sargılı pekleşmeli ve sargılı pekleşmesiz eğilme momentleri hesabı

    Confined-hardening and confined-neglecting hardening bending moment capacity of reinforced concrete beams

    ÜMİT DİŞLİLER

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    İnşaat MühendisliğiYıldız Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MUSTAFA ZORBOZAN

  4. A new model for plastic hinge length of rc columns and evaluation of seismic assessment documents

    Betonarme kolonlar için yeni bir plastik mafsal boyu modeli ve mevcut sismik verilerin değerlendirilmesi

    ALVAND MOSHFEGHI

    Yüksek Lisans

    İngilizce

    İngilizce

    2015

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. ALPER İLKİ

  5. Betonarme çerçeve sistemlerin kolonlarında bindirmeli boyuna donatı ek yerinin davranışa etkisinin belirlenmesine yönelik deneysel bir çalışma

    An experimental study to determine the effect of lap splice location in columns on the behaviour of rc frame type systems

    MURAD SAFARLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    PROF. DR. ERCAN YÜKSEL