Kranyospinal ışınlamalarda supine ve prone tedavi teknikleri için farklı tedavi parametreleri kullanarak birleşme bölgesi ve riskli organlardaki doz dağılımlarının değerlendirilmesi

Evaluation of the dose distribution at field junction and organs at risk for craniospinal irradiation at supine and prone patient position using different treatment parameters

  1. Tez No: 260148
  2. Yazar: ONUR MORA
  3. Danışmanlar: DOÇ. DR. SERRA ARUN KAMER, ÖĞR. GÖR. NEZAHAT OLACAK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Oncology, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2009
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 156

Özet

Bu çalışmanın amacı, spinal riski olan beyin tümörleri tedavisi için yaygın olarak kullanılan, dozimetrinin optimum tümör kontrolünü sağlamayı gerektirdiği titiz ve dikkatli yapılması gereken kranyospinal ışınlamada sırtüstü ve yüzüstü tedavi teknikleri için farklı tedavi parametreleri kullanılarak birleşme bölgesi ve riskli organlardaki doz dağılımlarının incelenmesidir.Dozimetrik ölçümler alınmadan önce, ışınlanacak TLD'ler kalibre edildi ve kullanılacak lineer hızlandırıcıların kalibrasyonu yapılıp, tolerans sınırları içinde çalışması sağlanmıştır. Ölçüm yapılacak antropomorfik fantomun, sırtüstü ve yüzüstü pozisyonda, başın üstünden sakral 4. vertebra hizasına kadar BT görüntüleri alındı. Radyolog ve Onkolog eşliğinde, ölçüm yapılmak istenen bölgeler belirlenerek, fantom üzerine aktarıldı. BTPS'de sırtüstü ve yüzüstü pozisyonlarda masa açısı, blok veya MLC gibi tedavi parametreleri ile sekiz farklı şekilde planlanan KSIT'leri için fraksiyon başına 1,8 Gy dozun tüm omuriliği kapsayacak şekilde homojen olarak dağıtılması sağlandı.Farklı sekiz planlama tekniği için elde edilen TLD ve BTPS verileri karşılaştırılmış ve analizleri yapılarak birbiriyle uyumlu bulunmuştur. Kranyospinal ışınlamada; kritik organlar olarak dikkate alınan kribriform plate, lensler, kohlealar, tiroid, ince bağırsak, böbrekler ve ovaryumlarda elde edilen TLD verileri kullanılarak değerlendirilmiş ve literatürle uyumlu olduğu saptanmıştır. Boyun ve spinal birleşme bölgelerinde ise, omurilik üzerinde ölçülen doz değerlerinin tüm teknikler için uluslararası doz protokolü ICRU 61'e uygun olan %95-107 arasında olması sağlanmıştır.Kliniğimizde de kullanılmakta olan sırtüstü pozisyonda masa açısı kullanılmadan, özel bloklarla koruma yapılarak planlanan KSI tekniği; tüm tedavi hacmindeki doz homojenliğinin daha iyi olması ve uygulama kolaylığından dolayı diğer tekniklere göre daha üstün olduğu belirlenmiştir.

Özet (Çeviri)

The purpose of this study is to research of the dose distribution at field junction and organs at risk for craniospinal irradiation treatment techniques at supine and prone position using different treatment parameters at brain tumors with the risk of spinal seeding. This treatment technique is widely used and needs dosimetric optimal tumor control.Dosimetric measurements taken before to be calibrated TLDs were used to calibrate linear accelerators whether, within the limits of tolerance have been made to work. CT images were acquired from over head to until the fourth sacral vertebrae level of the anthropomorphic phantom, at supine and prone positions. Measurements from certain regions were determined accompanied by the radiologist and oncologist and were transferred to the phantom. Eight different techniques planned with computerized treatment planning system (CTPS) for craniospinal irradiation at supine and prone position using by different treatment parameters such as couch angle, block or MLC and 1.8 Gy dose to cover all of the spinal cord as a homogeneous distribution are provided for per fraction.Measurements from eight different planning techniques (CTPS and TLD data) was analyzed compared and were found compatible with each other. TLD data has been evaluated and are compatible with literature were found for craniospinal irradiation in critical organs taken into account as cribriform plate, lenses, cochleas, thyroid, intestine, kidneys and ovaries.At the neck and spinal field junction, the spinal cord dose values measured on all techniques that are appropriate for the international dose protocol (ICRU 61) is provided between 95-107%.In our clinic that is being used in supine position, without couch angle and with special shields for CSI technique; the entire treatment volume and dose homogeneity is better than other techniques because of each of application was determined to be superior

Benzer Tezler

  1. Kranyospinal ışınlamalarda farklı tedavi tekniklerinin dozimetrik olarak karşılaştırılması

    Dosimetric comparison of different treatment techniques for craniospinal irradiation

    MUSTAFA ÇAĞLAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    YRD. DOÇ. DR. MURAT OKUTAN

  2. Kranyospinal ışınlamalarda tomoterapi cihazı ve klasik lineer hızlandırıcı cihazı için hacimsel yoğunluk ayarlı radyoterapi yöntemlerinin karşılaştırılması

    Comparison of helical tomotherapy and rapidarc treatment plans intomotherapy and vitalbeam machines in cranio-spinal irradiations

    GAMZE GÖKÇE AVŞAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Radyasyon OnkolojisiAcıbadem Mehmet Ali Aydınlar Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. KAZIM MERİÇ ŞENGÖZ

  3. Kranyospinal ışınlamalarda volumetrık ayarlı ark tedavi (VMAT), yoğunluk ayarlı radyoterapi (YART) ve üç boyutlu konformal radyoterapi (3B-KRT) tedavi planlama tekniklerinin karşılaştırılması

    Comparison of volumetric modulated arc therapy (VMRT), intensity modulated radiation therapy (İMRT) and 3D conformal radiotherapy (3D-XRT) treatment planning techniques for craniospinal irradiation

    ASLIHAN UZUN

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Fizik ve Fizik MühendisliğiEge Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. EMİNE SERRA KAMER

    ÖĞR. GÖR. NEZAHAT OLACAK

  4. Karniyospinal ışınlamalarda rando fantom kullanılarak farklı tedavi yöntemlerinde termolüminesans dozimetri tekniği yardımı ile doz tayini

    Determining of dose with thermoluminecent dosimeter technique in different treatment modalities using rando phantom in craniospinal irradiation

    HASAN UĞUR SARI

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    OnkolojiErciyes Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. SERDAR SOYUER

  5. Baş boyun radyoterapisinde tiroidin aldığı dozun araştırılması

    Investigation of the dose received by thyroid in the head and neck radiotherapy

    HEDİYE ACUN

    Yüksek Lisans

    Türkçe

    Türkçe

    2005

    Onkolojiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    DOÇ.DR. GÖNÜL KEMİKLER