Termal siklus test protokolünde belirtilen alt ve üst sıcaklık sınır değerlerinin in vivo ölçümü

In vivo measurement of cold and hot temperature extremes indicated in thermocycling test procedures

  1. Tez No: 266955
  2. Yazar: AYGÜL BAYDIR
  3. Danışmanlar: DOÇ. DR. ERDAL EROĞLU
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Termal siklus, alt sıcaklık sınır değeri, üst sıcaklık sınır değeri, termokupl, programlanabilir çözünürlüklü tek hatlı dijital termometre, Dental materyaller, Dental stres analizi, Sıcaklık, Termometreler, Testler, Thermocycling, cold temperature extreme, hot temperature extreme, programmable resolution 1-wire digital thermometer, thermocouple, Dental materials, Dental stress analysis, Temperature, Thermometers, Tests
  7. Yıl: 2010
  8. Dil: Türkçe
  9. Üniversite: Süleyman Demirel Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Dental malzemelerin test edilmesinde en çok kullanılan in vitro testlerden biri termal siklus test protokolüdür. Bu protokolün temel hedefi restoratif malzemelerin uzun dönemli klinik kullanım koşullarını taklit etmektir. Protokolü oluşturan önemli süreçlerinden biri olan alt ve üst sıcaklık sınır değerlerine ilişkin gerçekleştirilen in vivo çalışmalar farklı değerler bildirmektedir. Bu çalışmanı amacı termal siklus test yönteminde kullanılan alt ve üst sıcaklık sınır değerlerinin in vivo olarak tespit edilmesidir.Bu çalışma S.D.Ü. Diş Hekimliği Fakültesi öğrencilerinden gönüllü 50 birey ile gerçekleştirilmiştir. Bireylerin üst çene ölçüleri alınarak çalışma modelleri elde edilmiş ve bu modeller üzerinde 2mm kalınlığında plastik plaklar kullanılarak splintler yapılmıştır. Uyumlandırılan splintler üzerinde dört bölgeye (11?21 numaralı dişlerin bukkal interproksimal/a bölgesi, 11?21 numaralı dişlerin palatinal interproksimal/b bölgesi, 16 numaralı dişin bukkal/c bölgesi ve 26 numaralı dişin palatinal yüzüne/d bölgesi) iki farklı tip ısı algılayıcı (programlanabilir çözünürlüklü tek hatlı dijital termometre ve termokupl) yerleştirilmiştir. Her iki ısı algılayıcı ile bireylerde sıcak ve soğuk içeceklerin tüketimi sırasında ağızda meydana gelen alt ve üst sıcaklık sınır değerleri ölçülmüştür. En yüksek üst sıcaklık sınır değeri programlanabilir çözünürlüklü tek hatlı dijital termometre ile 54,37°C (b bölgesi), termokupl ile 53,78°C (a bölgesi) olarak ölçülmüştür. En düşük alt sıcaklık sınır değeri ise programlanabilir çözünürlüklü tek hatlı dijital termometre ile 12,62°C (b bölgesi), termokupl ile ise 6,07°C (a bölgesi) olarak ölçülmüştür.Çalışmamızın sonuçları termal siklus test protokolü için günümüze dek yapılan çalışmalarda en sık kullanılan alt-üst sıcaklık sınır değeri olan 5?55°C'nin uygunluğunu desteklemektedir.

Özet (Çeviri)

Thermocycling is the most common test procedure for dental materials testing. The main goal of this procedure is to simulate long term clinical conditions of restorative materials. The in vivo studies about hot and cold temperature extremes report different results. The aim of this study is to determine cold and hot temperature extremes of thermocycling test procedures.This study is achieved by 50 voluntary dental students of S.D.U. Upper jaw impressions of subjects were made and models were prepared by dental stone. Plastic splints in 2mm thickness were prepared. The splints were adapted to the subjects and two types (programmable resolution 1-wire digital thermometer and K type thermocouple) of thermal sensors were placed on four different parts (buccal interproximal surface of 11?12/region a, palatinal interproximal surface of 11?12/region b, buccal surface of 16/region c and palatinal surface of 26/region d) of the splints. Cold and hot temperature extremes occured during consumption of hot and cold drinks were measured by these thermal sensors. Hot temperature extreme was measured as 54.37°C (region b) by programmable resolution 1-wire digital thermometer and 53.78°C (region a) by K type thermocouple. Cold temperature extreme was measured as 12.62°C (region b) by programmable resolution 1-wire digital thermometer and 6.07°C (region a) by K type thermocouple.The resuts of this study advocate suitability of hot and cold temperature extremes commonly used (5?55°C) in thermocycling procedures in the studies up to date.

Benzer Tezler

  1. Nükleer rezonasta moleküler yapıların incelenmesi (yapısal faz geçiş kuramları üzerine bir inceleme)

    Başlık çevirisi yok

    ABDURRAHMAN ANDİÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Fizik ve Fizik MühendisliğiUludağ Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. AYTAÇ YALÇINER

  2. Çeltik kabuklarının yalıtım malzemesi olarak kullanılması

    Başlık çevirisi yok

    B.CİHAN ÇELEBİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MEHMET KIRBIYIK

  3. Nar konsantresinin dondurularak ve kimyasal yöntemlerle saklanması sırasında meydana gelen değişmeler üzerine bir araştırma

    Başlık çevirisi yok

    İLHAN BODUR

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gıda MühendisliğiEge Üniversitesi

    Tarım Ürünleri Teknolojisi Ana Bilim Dalı

    DOÇ. DR. YURDAGEL ÜNAL

  4. Bornova (İzmir) koşullarında çeşitli kültür bitkilerinde zarar yapan Dolycoris baccarum (L.) (Heteroptera: Pentatomidae)'un biyolojisi ve ekolojisi üzerinde araştırmalar

    Investigations on the biology and ecology of Dolycoris baccarum (L.) (Heteroptera: Pentatomidae) which attacks to various plants of economic importance at Bornova (İzmir)

    YUSUF KARSAVURAN

    Doktora

    Türkçe

    Türkçe

    1986

    ZoolojiEge Üniversitesi

    Bitki Koruma Ana Bilim Dalı

    PROF. DR. FEYZİ ÖNDER

  5. Mevcut kaplıca yerleşmelerinin iyileştirilmesini etkileyen faktörler ve Yeni Kaplıca örneği

    Adjustment principles of spas in Turkey, Yeni Kaplıca being the sample

    DOĞAN ÜMİT YÜCEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İşletmeGazi Üniversitesi

    Mimarlık Ana Bilim Dalı

    DOÇ. DR. YÜKSEL ERDEMİR

  6. Dört zamanlı türbaşarj direk püskürtmeli bir dizel motorunun bilgisayar ile sümülasyonu

    Computer aided simulation of a fourstroke turbocharged direct-anjection diesel engine

    MUSTAFA BALCI

    Doktora

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiGazi Üniversitesi

    PROF. DR. OĞUZ BORAT