Farklı elektron enerjilerinde kaynak-yüzey mesafesine bağlı doz dağılımlarının araştırılması

Investigation of dose distribution connect to source-surface distance in different electron energies

  1. Tez No: 288959
  2. Yazar: ŞAMİL ARDUÇ
  3. Danışmanlar: YRD. DOÇ. DR. OKAN ORHAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Onkoloji, Radiology and Nuclear Medicine, Oncology
  6. Anahtar Kelimeler: Elektron Işını, Kaynak-Cilt Mesafesi (SSD), Su Fantomu, Yüzde Derin Doz (%DD), Deri, Doz-cevap ilişkisi-radyasyon, Radyasyon, Radyasyon dozajı, Radyometri, Radyoterapi, İyon odası, Electron Beam, Source-Skin Distance (SSD), Water Phantom, Percent Depth Dose (%DD), Skin, Dose-response relationship-radiation, Radiation, Radiation dosage, Radiometry, Radiotherapy, Ionization chamber
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: Erciyes Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Elektron ışınları, 50 yılı aşkın bir süredir yüzeyel kanserlere uygun radyasyon dozunu uygulamak için önemli bir modalite olmuştur. Elektron ışın tedavisi kanser tedavilerinde geniş bir şekilde kullanılmaktadır. Elektron ışının kısa erişim mesafesi ve hızlı doz düşüşü sayesinde tümörün altındaki dokular ve yapılar korunurken, yüzeye yakın lezyonların tedavisine olanak tanımaktadır. Hedef volüme homojen bir doz, güvenli bir uzatılmış kaynak yüzey mesafeli (SSD) elektron tedavisinde uygulanan doz, merkez eksen derin doz ve ışın düzlüğünün ile ilgili verilerin bilinmesiyle mümkündür.Bu çalışmanın amacı 6 MeV, 9 MeV ve 12 MeV electron enerjilerinin farklı SSD'lerde yüzde derin dozlarını (%DD), doz profillerini, doz düzgünlüğünü, doz simetrisini, en olası enerjisini, ortalama enerjisini, pratik mesafesini, yarı değer derinliğini ve maksimum doz parametrelerini incelemektir. Varian DHX doğrusal hızlandırıcıda üretilen elektron ışınlarının karakteristlikleri 100 cm standart SSD ve 105 cm, 110 cm, 115 cm uzatılmış SSD'lerde sunuldu. Ölçümler, kalibrasyon için rutinde kullanılan 50x50x50 cm3 su fantomundaki bir iyon odası kullanılarak yapıldı.Bu ölçümlere göre, tüm elektron ışın enerjileri için maksimum doz derinliği ile fantom yüzeyi arasındaki bölgede, SSD arttıkça derin doz azalmaktadır. Maksimum doz derinliğinin altındaki bölgede uzatılmış SSD'nin etkileri dikkate alınmayacak kadar küçüktür. Sonuç olarak tüm elektron enerjileri için SSD arttıkça yüzey dozu azalmaktadır. Aynı zamanda simetri, düzgünlük ve penumbra değerleri, uluslararası protokollerdeki tolerans sınırları içerisinde bulundu.

Özet (Çeviri)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation beams. Electon beam therapy is widely used in treatment of cansers. The rapid dose fall-off and short range of an electron beam enable the treatment of lesions close to the surface, while sparing the underlying tissues and structures.A uniform dose to the target volume is required with a knowledge of delivered dose, central axis depth dose and beam flatness at safe electron treatment an extended source to distance (SSD).The purpose of this study is to investigate percentage depth dose (%DD), dose profiles, dose flatness, dose symmetry, most probably energy, avarage energy, practical range, half-value depth and maximum dose parameters of electron energies of 6 MeV, 9 MeV and 12 MeV at different SSDs. Characteristics of electron beams of the Varian DHX Lineer Accelarator are presented at a nominal SSD of 100 cm and extended SSDs of 105 cm, 110 cm, 115 cm. Measurements were performed by an ionization chamber in a 50x50x50 cm3 water fantom which is routinely used for calibration.According to the measurements in the region between the phantom surface and depth of maximum dose, the depth dose decreases as the SSD increases for all electron beam energies. The effects of extended SSD in the region beyond the depth of maximum dose are unobservable, considered minimal. As a result of this study surface dose is decreased as the SSD increased moderately for all energies. At the same time values of symmetry, flatness and penumbra are founded within tolerance limits of international protokole.

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  2. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  3. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Üroloji Ana Bilim Dalı

    Yükleniyor...

  4. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    Yükleniyor...