2,4-dinitrosoresorcinol ile specktrofotometrik kobalt tayini ve kompleksometrik metal tayininde kullanılan ligandların xad-7 üzerine immobilizasyonu ile fiber - optik kimyasal sensör geliştirilmesi
Başlık çevirisi mevcut değil.
- Tez No: 33508
- Danışmanlar: DOÇ. DR. PERİHAN ÇAĞLAR
- Tez Türü: Doktora
- Konular: Kimya, Chemistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 1994
- Dil: Türkçe
- Üniversite: Fırat Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 155
Özet
I ÖZET Doktora Tezi 2,4-DlNlTROSORESORCİNOL İLE SPEKTROFOTOMETRİK KC8ALT TAYİNİ VE KOMPLEKSOMETRİK METAL TAYİNİNDE KULLANILAN LİGANDLARIN XAD-7 ÜZERİNE İMMOBİÜZASYONU İLE FİBER-OPTİK KİMYASAL SENSOR GELİŞTİRİLMESİ Ali ÖLÇÜCÜ Fırat Üniversitesi Fen Bilimleri Enstitüsü Kimya Anabilim Dalı 1994, Sayfa:140 Bu çalışmada kobalt 2,4-dinitrosoresorcinol (DNR) ile spektrofotometrik olarak tayin edildi ayrıca DNR ve 1-nitroso-2-naftol (NN) ligandlarının amberlit XAD-7 polimerine immobilize edilmesiyle Fe ve Cu metalleri için fiber-optik kimyasal sensör geliştirildi. Bu amaçla yapılan çalışmada sulu ortamda Co+2-DNR kompleksi oluşturularak Co için basit, hızlı ve duyarlı spektrofotometrik bir yöntem geliştirildi. 397 nm dalgaboyunda kompleks oluşum süresi 30 dk., çalışma pH'ı 7 (H2P04“/HP04= tamponu ile ayarlandı) ve stokiyometrisi Co+2-DNR (1:6) olarak belirlendi. Kompleksin oluşum sabitinin 3.403x1 038, lineer çalışma aralığının 1.0x10'2-3.0 mg L”1, molar soğurma katsayısının 3.635x104 mol L“1cm'1 ve tayin sınırının ise 1.0x10”2mg L"1 Co+2 olduğu bulundu. Geliştirilen yöntemle Euoronorm-CRM No.585-1 ve Analysen-Kontrolprobe 530-1 ferrokrom standartlarında Co tayin edildi. Sonuçlar, standartlardaki gerçek değerlere oldukça yakın bulundu. Fiber-optik kimyasal sensör hazırlamak için ise seçilen DNR ve NN ligandlarının XAD-7'ye immpbiiizasyonundaki çeşitli değişkenler incelenerek, optimum koşullar; polimer boyutu her iki ligand için de 44 um, ligand derişimi DNR için 2000 mg L'1 NN için 3000 mg L'1, süre DNR için 3 saat NN için 6 saat, pH DNR için 3 NN için 1 ve sıcaklık DNR için 5°C NN için -20° C olarak belirlendi. Bu optimum koşullarda hazırlanan DNR probunun Fe+2 ve NN probunun Cu+2 iyonları için fiber-optik sensör olarak kullanılabileceği kanıtlandı. ANAHTAR KELİMELER: Spektrofotometri, Kobalt, Dinitrosoresorcinol, Immobilizasyon, Fiber-Optik Sensör, Demir, Bakır.
Özet (Çeviri)
II SUMMARY Ph.D. Thesis THE SPECTROPHOTOMETRY COBALT DETERMINATION WITH 2,4-DINITROSORESORCINOL AND THE DEVELOPMENT OFTHE FIBER-OPTIC CHEMICAL SENSORS BY IMMOBILIZATION ON XAD-7 OFUGANDS USED IN DETERMINATION OF COMPLEXOMETRIC METAL IONS ABÖLÇÜCÜ University of Fırat Graduate School of Natural and Applied Sciences Department of Chemistry 1994, Page:140 In this study cobalt was determined by spectrophotometries!^ by using 2,4-dinitrosoresorcinol (DNR) and also the fiber-optic chemical sensors for Fe and Cu metals were developed by immobilization of DNR and 1-nitroso-2-naphthol (NN) IJgands respectively on amberlite XAD-7 polymer. For this purpose, Co+2 -DNR complex was formed in solution and thus a simple, rapid and sensitive spectrophotometri method for Co was developed. It is found that the complex formation time is 30 minutes, pH is 7 (buffered by H2P04“/HP04= solution) and its stoichiometry is Co+2-DNR (1:6) at 397 nm. The following properties of complex were investigated: The formation constant of complex is 3.403x10 38, the linear working range is 1.0x10”2-3.0 mg L“1, the molar absorptivity coefficient is 3.635x1 04 mol L”1 cm-1 and detection limit is 1.0x10'2 mg L'1 Co+2. Co was determined, in Euoronorm-CRM No.585-1 and Analysen-Kontrollprobe 530-1 ferrochrome standards by the method developed in this study. The results were found very close to actual values in the standards. In order to prepare fiber-optic chemical sensors, the different variables in the immobilization of the selected DNR and NN ligands on XAD-7 were investigated and the optimum conditions were determined as follows; polymer dimension for both ligands is 44 ixm, ligand concentrations are 2000 mg L“1 and 3000 mg L”1, times are 3 and 6 hours, pHs are 3 and 1, temperatures are 5 °C and -20 °C for DNR and NN ligands respectively. It was proven that the DNR and NN probes prepared under the optium conditions can be used as fiber-optic chemical sensors for Fe+2 and Cu+2 ions respectively. KEY WORDS: Spectrophotometer, Cobalt, Dinitrosoresorcinol, Immobilization, Fiber-Optic Sensor, Iron, Copper.
Benzer Tezler
- Elazığ yöresi sularında kobaltın zenginleştirilerek alevli atomik absorpsiyon spektrofotometresi ile tayini
Determination of cobalt in waters around Elazığ region by enrichment method by flame atomic absorption spectrophotometer
SERGÜL KOÇOĞLU
- p-dimetilanilinazometinfenollerin oksidatif kondenzasyon polimerizasyonu
Oxidative condensation polymerization of p-dimethylanilineazomethinephenols
NURAY YILMAZ BARAN
- 2,4-d ve dikamba herbisitlerinin fasulye (Phaseolus vulgaris L.) köklerindeki genotoksik etkilerinin rapd ve comet assaylerle belirlenmesi
Determination of genotoxic effects of 2,4-d and dicamba herbicides in bean (Phaseolus vulgaris L.) roots by rapd and comet assays
AHMET BOZDAĞ
Yüksek Lisans
Türkçe
2009
BiyolojiAfyon Kocatepe ÜniversitesiBiyoloji Ana Bilim Dalı
YRD. DOÇ. DR. SÜLEYMAN CENKCİ
- 2.4 GHz LC-VCO design based on active inductors
2.4 GHz aktif enduktans tabanlı LC-VCO tasarımı
ALPHAN SAHİN
Yüksek Lisans
İngilizce
2008
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiElektronik ve Haberleşme Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. NİL TARIM