Bir göze refraktif diğer göze difraktif multifokal göz içi lensi implantasyonu sonrası görsel sonuçlar

Visual outcomes after refractive multifocal intraocular lens implantation into one eye and diffractive one into the other eye

  1. Tez No: 352679
  2. Yazar: REVAN YILDIRIM KARABAĞ
  3. Danışmanlar: PROF. DR. ÜZEYİR GÜNENÇ
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Göz Hastalıkları, Eye Diseases
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2014
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Göz Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 89

Özet

Amaç: Katarakt cerrahisinde“mix and match”yaklaşımı ile multifokal göz içi lensi (GİL) implantasyonu yapılan hastaların görsel sonuçlarını değerlendirmek. Metod: Bu prospektif, randomize olmayan, vaka kontrol çalışmasına 20 hasta (40 göz) dahil edildi. Refraktif multifokal GİL (ReZoom NXG1) hastaların baskın gözlerine implante edilirken, difraktif multifokal GİL (Tecnis ZMA00) baskın olmayan gözlerine implante edildi. Hastalar toplam 6 ay takip edildi. Katarakt cerrahisinden 1, 3 ve 6 ay sonra monoküler ve binoküler düzeltilmemiş uzak, ara mesafe ve yakın görme keskinlikleri (logMAR), kontrast duyarlılık düzeyleri ölçüldü. Postoperatif 6. ayda defokus eğrileri, okuma hızları, gözlükten bağımsızlık, halo ve kamaşma semptomları da değerlendirildi. Postoperatif yaşam kalitesi, NEI VFQ-25 (National Eye Institute Visual Function Questionnaire-25) anketinin Türkçe versiyonu ile değerlendirildi. Sonuçlar: Çalışma grubu, yaş ortalaması 69.45 ± 10.76 (31-86) yıl olan 8 kadın, 12 erkekten oluşmaktaydı. Postoperatif 6. ayda ReZoom implante edilen gözlerde ortalama sferik ekivalan -0.04 ± 0.12 D iken, Tecnis implante edilen gözlerde -0.04 ± 0.12 D idi. Postoperatif 6. ayda düzeltilmemiş uzak ve ara mesafe görme keskinlikleri ReZoom implante edilen gözlerde Tecnis implante edilenlerden anlamlı daha iyi bulundu (sırasıyla, p=0.026 ve p=0.037). Düzeltilmemiş yakın görme keskinlikleri arasında anlamlı fark bulunmadı (p>0.05). Postoperatif 6. ayda ortalama binoküler düzeltilmemiş uzak görme keskinlikleri -0.05±0.1 logMAR, ortalama binoküler düzeltilmemiş ara mesafe görme keskinlikleri 0.1±0.2 logMAR, ortalama binoküler düzeltilmemiş yakın görme keskinlikleri 0.1±0.1 logMAR'dı. Kontrast duyarlılık, okuma hızı, halo ya da kamaşma açısından gruplar arasında istatistiksel anlamlı fark tespit edilmedi (p

Özet (Çeviri)

Purpose: To assess the visual outcomes in patients who underwent cataract surgery with multifocal intraocular lens (IOL) implantation using a“mix & match”approach. Methods: Twenty patients (40 eyes) were involved in this prospective, nonrandomized, casecontrol study. Refractive multifocal IOLs (ReZoom NXG1) were implanted in patients' dominant eyes and diffractive multifocal IOLs (Tecnis ZMA00) were implanted in their nondominant eyes. Patients were followed for 6 months. Monoocular and binocular uncorrected distance, intermediate and near vision acuity (logMAR), contrast sensitivity levels were measured 1, 3 and 6 months later after cataract surgery. Defocus curves, reading speeds, patient satisfaction, spectacle dependence, halo and glare symptoms were also evaluated at 6 month after the surgery. Postoperative quality of life was assessed with the Turkish version of NEI VFQ-25 (National Eye Institute Visual Function Questionnaire-25). Results: The study group consists of 8 females and 12 males, with mean age 69.45 ± 10.76 (31-86) years. At 6 months after the surgery the mean spherical equivalent was -0.04 ± 0.12 D in ReZoom implanted eyes and -0.11 ± 0.2 D in Tecnis implanted eyes. The uncorrected distance and intermediate visual acuity levels were significantly better in ReZoom implanted eyes at 6 months after the surgery (p=0.026 and p=0.037,respectively). There was no statistically significant difference in the uncorrected near viasual acuity (p>0.05). At the final visit, the mean binocular uncorrected distance visual acuity was -0.05±0.1 logMAR, the mean binocular uncorrected intemediate visual acuity was 0.1±0.2 logMAR and the mean binocular uncorrected near visual acuity was 0.1±0.1 logMAR. There was no statistically significant difference in contrast sensitivity, reading speed, halos, or glare between the groups (p

Benzer Tezler

  1. Sklera çökertmesi uygulanan retina dekolmanlı olgularda, OCT ile ölçülen retina kalınlığı ile final görme keskinliği arasındaki ilişki

    Assessment of the relationship between the neurosensorial retina thickness and final visual acuity in successfully operated cases of rhegmatogenous retinal dettachment

    YAHİA SEDDİK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2002

    Göz Hastalıklarıİstanbul Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı

    PROF.DR. HÜSNÜ GÜZEL

  2. Kataraktı ve yüksek astigmatizması olan hastalarda torik göz içi lens implantasyonu sonuçlarımız

    Başlık çevirisi yok

    MEHMET VURAL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    Göz HastalıklarıSağlık Bilimleri Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı

    UZMAN NİLGÜN SOLMAZ

  3. Penetran keratoplasti ve lameller keratoplasti sonrası greft sağ kalım ,greft rejeksiyon insidansları, görsel sonuçları ve erken-geç dönem komplikasyonların karşılaştırılması

    Comparison of visual results, graft survival rates, incidences of graft rejection, and early-late complications after penetrating keratoplasty and lamellar keratoplasty

    EVELYNE GIRUKWIGOMBA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2020

    Göz HastalıklarıSağlık Bilimleri Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı

    PROF. DR. HATİCE ELVİN YILDIZ

  4. Müllit/zirkonya kompozitlerin, müllit tanelerinin yönlenmesine bağlı tokluğu

    Toughness mullite/zirconia composites related to the orientation of mullite grains

    AGAH EMRE SÜNBÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    2007

    Mühendislik BilimleriGebze Yüksek Teknoloji Enstitüsü

    Malzeme Bilimi ve Mühendisliği Ana Bilim Dalı

    Y.DOÇ.DR. YAHYA KEMAL TÜR

  5. Poly(lactic acid) based nanocomposites: Mechanical, thermal and rheological properties and morphology

    Poli(laktik asit) bazlı nanokompozitler: Mekanik, ısısal ve reolojik özellikleri ve morfolojisi

    EDA AÇIK

    Doktora

    İngilizce

    İngilizce

    2014

    Kimya MühendisliğiOrta Doğu Teknik Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    PROF. DR. ÜLKÜ YILMAZER