Böbrek radyofrekans ablasyon uygulamalarında termal etkiye bağlı oluşan karbonlaşmanın etkisinin azaltılmasında çeşitli sıvı solüsyonların etkinliğinin histopatolojik ve manyetik rezonans görüntüleme ile karşılaştırılması; ex vivo

Histopathologically and by magnetic resonance imaging the evaluation of effectiveness of different liquid solitions to decrease the carbonization from the thermal effect during renal MF ablation aplications; ex vivo

  1. Tez No: 385227
  2. Yazar: AHMET CENGİZ
  3. Danışmanlar: DOÇ. DR. OSMAN TEMİZÖZ
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: Trakya Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Dahili Tıp Bilimleri Bölümü
  12. Bilim Dalı: Radyoloji Ana Bilim Dalı
  13. Sayfa Sayısı: 64

Özet

Radyofrekans ablasyon, belirli boyutta ve belirli klinik özelliklere sahip olan böbrek tümörlerinin tedavisinde gün geçtikçe ön plana çıkan bir tedavi alternatifi haline gelmektedir. radyofrekans ablasyon son yıllarda popüler olmasının yanı sıra inoperabl hastaların primer ve sekonder malignensi tedavisinde cerrahi rezeksiyona alternatif yöntem olarak kabul görmektedir.Yine de günümüz radyofrekans ablasyon teknolojisi tek kullanımda ancak 3.5- 4.5 cm'lik sınırlar dahilindeki dokuların yakılmasına olanak sağlamaktadır. monopolar radyofrekans ablasyon işlemi esnasında doku ve elektrod ara yüzeyinde her seferinde ani bir ısı artışı olması, dokunun kurumasına ve elektrod ucuyla temas halindeki dokunun kömürleşmesine neden olur. Bu durum radyofrekans enerji etkisinin ölü doku kitlesinin sınırlarının ötesine geçmesini engeller ve bu da ileri dokulardaki koagülasyonu durdurur. Monopolar radyofrekans ablasyonun sınır sorununu çözebilmek için daha önceki çalışmaları göz önünde bulundurarak radyofrekans ablasyon yönteminde enjekte edilen salinin elektriksel ve termal iletkenliği arttırabildiği ve hipertonik salin'in yüksek kaynama noktasının elektroda yakın olan karaciğer dokusunun ani kaynamasını önleyebilmesinden esinlenerek termal etkiye bağlı oluşan karbonlaşmanın etkisinin azaltılmasında 6 grup değişik konsantrasyonlarda ve özellikte sıvı solüsyonunun (Grup 1 % 0.9 Sodyum klorür solüsyonu (n=6) ,Grup 2 % 3.6 Sodyum klorür solüsyonu (n=6) , Grup 3 % 0.9 Potasyum klorür solüsyonu (n=6) , Grup 4 % 3.6 Potasyum klorür solüsyonu (n=6) , Grup 5 %5 dekstroz solüsyonu (n=6), Grup 6 Ringer laktat solüsyonu (n=6) etkinliğinin histopatolojik ve manyetik rezonans ile karşılaştırılması ile ilgili (ex vivo) sığır böbreklerinde bir çalışma yürüttük. Bu çalışmada ablasyon alanlarının boyutlarını ve varsa makroskopik-mikroskopik düzeyde karbonlaşmanın lehine olabilecek morfolojik değişiklikleri değerlendirdik. Çalışmamızın asıl amacı olan oluşturduğumuz ablasyon alanlarında makroskopik-mikroskopik düzeyde karbonlaşma gözlemlenmemiştir. bununla birlikte kullanıdığımız çeşitli sıvı solusyonlarında radyofrekans ablasyonla oluşturulan kuaglasyon alanları arasında boyutusal olarakta anlamlı derecede fark izlenmemiştir (p

Özet (Çeviri)

Radiofrequency ablation is becoming increasingly prominent treatment alternative in the renal tumors within certain dimesions and with certain clinic properties in addition to being popular, radiofrequency ablation is recognized as an alternative method to the surgical resection of primary and secondary malignancies in recent years in the treatment of inoperable patients.Contemporary radiofrequency technology allow the ablation zones within 3.5 to 4.5 cm with a single probe insertion. During monoplanar radiofrequency ablation, with each radiofrequency heating, sudden temprature increase in tissue-electrode interface cause tissue dessication and carbonization. The carbonization in turn retard the coagulation necrosis beyond the limits of the dead tissue due to a resultant decrease in energy transmission. To solve the carbonization and conductivity problem in monopolar radiofrequency ablation, inspired from the knowledge that during the radiofrequency procedure the injected saline could increase the termal and electrical conductivity and also high boiling point of the saline could prevent nearby tissue carbonization and also by taking the previous studies in the considiration, we conducted the following study in which histopathologically and by magnetic rezonance we compared the efectiveness of 6 groups of liquid solutions in different concentration and with different characteristics (Group 1, 0.9% NaCl solution (n = 6), Group 2, % 3.6 NaCl solution (n = 6), Group 3, 0.9% KCl solution (n = 6), Group 4 % 3.6 KCl solution (n = 6), Group 5 and 5% dextrose solution (n = 6), Group 6 Ringer's lactate solution (n = 6) to alleviate the tissue carbonization in (ex vivo) bovine kidney.In this study we compared the ablation zone dimensions and morphological changes that could be related to the carbonization in macroscopic and microscopic level. No carbonization observed in neighter microscopic nor macroscopic level in ablation zones. And also no dimensional differences observed in ablation zones between different liquid solution groups (p

Benzer Tezler

  1. Küçük renal tümörlerin tedavisinde US/BT eşliğinde ablatif tedaviler

    US/CT guided ablative therapies ın small renal masses

    SEDA ALADAĞ KURT

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2012

    Radyoloji ve Nükleer TıpGazi Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. CEM YÜCEL

  2. Metastatik renal hücreli kanser tedavisinde tirozin kinaz inhibitörlerinin etki ve yan etkisinin retrospektif değerlendirilmesi

    Retrospective evaluation of the effect and side effect of tyrosi̇ne kinase inhibitors on the treatment of metastatic renal cell carcinomas

    ABDÜLKADİR ŞAHİN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    OnkolojiUludağ Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    DOÇ. DR. ERDEM ÇUBUKÇU

  3. Metastatik renal hücreli kanserlerin retrospektif değerlendirilmesi

    Retrospective planning of metastatic renal cell carcinoma

    SEVİNÇ TUĞÇE GÜVENİR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    OnkolojiUludağ Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    PROF. DR. ÖZKAN KANAT

  4. Yüksek yoğunluklu odaklanmış ultrason (HIFU) dalgalarının dana karaciğeri üzerinde oluşturduğu termal ablasyonun görüntü işleme teknikleri ile analizi

    Analysis of thermal ablation of high density focused ultrasound (HIFU) waves on calf's liver with image processing techniques

    KÜBRA KILIÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolKocaeli Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    PROF. DR. EMİNE DOĞRU BOLAT

  5. Resveratrolün akciğer kanseri hücre hattında ısı şok proteini-90 ve asimetrik dimetil arjinin düzeylerine etkisi

    Effect of resveratrol on heat shock protein-90 and asymmetric dimethyl arginine levels in lung cancer cell line

    FATMA AKAT

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    BiyokimyaSelçuk Üniversitesi

    Tıbbi Biyokimya Ana Bilim Dalı

    PROF. DR. HÜSAMETTİN VATANSEV