Geri Dön

Ektatik kornea hastalıklarında sert gaz geçirgen kontakt lenslerin güvenilirlik ve etkinliği

The efficacy and safety of rigid gas permeable lenses in corneal ectasias

  1. Tez No: 433442
  2. Yazar: ZEYNEP BAŞ
  3. Danışmanlar: PROF. DR. ÖZLENEN ÖMÜR GÜNDÜZ
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Göz Hastalıkları, Eye Diseases
  6. Anahtar Kelimeler: Cerrahi-göz, Göz hastalıkları, Keratokonus, Kontak lensler, Kornea, Korneal hastalıklar, Refraksiyon-oküler, Refraktif kusurlar, Surgery-eye, Eye diseases, Keratoconus, Contact lenses, Cornea, Corneal diseases, Refraction-ocular, Refractive errors
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Göz Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Korneal ektazili gözlerde Rose K2 ve Orbiflex K korneal sert lenslerin güvenilirlik ve etkinliğinin değerlendirilmesi Gereç-Yöntem: Ankara Üniversitesi Tıp Fakültesi Göz Hastalıkları Anabilim Dalı Kornea ve Kontakt Lens Servisi'ne Ocak 2008- Ağustos 2015 tarihleri arasında korneal ektazi tanısı ile gelen ve kliniğimizde en az 2 takibi olan olgular dahil edildi. Tüm hastalar; kornea ektazi tipleri, demografik verileri, görme keskinlikler, manifest refraksiyon değerleri, biyomikroskopik muayene bulguları, keratometri, korneal topografi açısından değerlendirildi. Bulgular:Çalışmaya 483 olgunun 860 gözü dahil edildi. Çalışmaya dahil edilen olguların %54'ü erkek, %46'sı kadındı. Çalışmaya hastaların korneal sert lens uygulanan gözleri dahil edildi ve dahil edilen gözlerin %49.9'ü sağ göz, %50.1'i sol göz idi. Hastaların ortalama yaşı 26.7±9.9 idi. 855 gözde keratokonus, 1 gözde keratoglobus, 3 gözde PMD, 1 gözde post-graft ektazi mevcuttu.Hastalar Amsler-Krumeich evresine göre sınıflandırıldıklarında; evre 1 KC -274 göz (%31.9), evre 2 KC -302 göz (%35.1), evre 3 KC -95 göz (%11), evre 4 KC -189 göz (%22) olarak gruplandırılmıştır. Hastaların düzeltilmemiş görme keskinlikleri, gözlükle düzeltilmiş görme keskinlikleri, korneal sert lens ile düzeltilmiş görme keskinlikleri ve korneal sert lens reçete edildikten sonra takiplerindeki en son muayenelerindeki görmeleri sırasıyla; 0.99 ± 0.60 (0-2.6), 0.39 ± 0.39 (0-2.6) , 0.05 ± 0.33 (0-9), 0.08 ± 0.54 (0-9) logMAR'dır. Hastalara uygun duruş bulunanana kadar denenen lens sayısı ortalama 2.01±1.0 (1-6) idi. İlk denenen lensin BCR'ı ile uygun duruş elde edilen lensin BCR'ı arasında ortalama 0.15±0.10 fark vardır. Olguların 793'ünde korneal sert lens başarılı şekilde uygulanmış ve reçete edilmiştir. Altmış yedi gözde (%7.8) korneal sert lens uyumsuzluğu tespit edilmiş ve korneal sert lens reçete edilmemiştir. Bu hastalara; INTACS , PPK , Kerasoft ve Skleral lens önerilmiştir. Hastaların izlemleri boyunca 107 göze yeniden reçete yazılma gereksinimi duyulmuştur. Reçete yazılan hastalardan 162 (%18.8) olgu lensini hiçbir zaman almamıştır. 91 (%10.6) olgu ise lensini almış kontrole gelmiş fakat takiplerinde lensini bırakmıştır. Olguların 749'unda (%87.1), takip süreleri boyunca reçete edilen korneal sert lens'nin BCR veya dioptri değerleri değiştirilmemişken, 83 olguda (%9.7) reçete 1 kere, 21 olguda (%2.4) 2 kez, 5 olguda (%0.6) 3 kez ve 2 hastada (%0.2) 4 kez değiştirilmiştir. Ortalama takip süresi 14.3 ± 18.1 (6-127) aydı. Takip boyunca 1 olgu gözündeki steril infiltrat dışında komplikasyonla karşılaşılmadı. Sonuç:Korneal sert lensler KC'da her evrede refraktif kusuru etkili olarak düzeltirler. Uygulamaları ve bakımları kolay olan bu lensler uzun dönem takipte ciddi komplikasyonlara neden olmaksızın güvenle kullanılabilirler.

Özet (Çeviri)

Purpose: To evaluate the safety, efficacy, and on-eye performance of Rose K2 and Orbiflex K contact lens fitting in ectatic corneal diseases Materials and Methods:The charts of patients who were fit with rigid gas permeable lenses in Ankara University Medical Faculty at January 2008- August 2015 were reviewed retrospectively. The reason for lens fit, the number of trial lenses required for ideal fit, centration and stabilization of the contact lens, uncorrected, spectacle-corrected, and contact lens-corrected visual acuities, slit lamp biomicroscopy findings and topographic findings are recorded. Results: Eight hundred and sixty eyes of 483 patients were included in the study. The mean patient age was 26.7±9.9. 54% of the cases were male and 46% of the patients were female. Indications included, 855 eyes with various degrees of keratokonus, 1 eye with keratoglobus, 3 eyes with pellucid marginal degeneration, 1 eye with postgraft ectasia. Among those patients 274 eyes (%31.9) had mild, 302 eyes (%35.1) had moderate, 95 eyes (%11) had severe and 189 eyes (%22) had advanced keratoconus. The mean uncorrected, best spectacle corrected and the best contact lens corrected visual acuities were 0.99 ± 0.60 (0-2.6), 0.39 ± 0.39 (0-2.6) , 0.05 ± 0.33 (0-9), 0.08 ± 0.54 (0-9) logMAR respectively. The mean trial lens count until succesfull fit was 2.01±1.0 (1-6). The mean difference between the first diagnostic lens and the lens prescription was 0.15±0.10.In 793 eyes adequate fit with rigid gas permeable lenses were achieved and prescribed. Sixty-seven eyes had (%7.8) RGP lens failure and couldn't get a presciption. To these patients, INTACS, keratoplasty, Kerasoft lenses and Scleral lenses had been recommended. Through their follow-ups 107 eyes needed re-prescribtion. From those who have been prescribed, 162 eyes (%18.8) had never purchased the lens. 91 cases (%10.6) had bought their lenses and came for their control visits but discontiuned after purchasing. In 749 cases (%87.1), the prescribtion remained same throughout theşr follow-ups, however in 83 cases (%9.7) prescription changed 1 time, 21 cases (%2.4) 2 times, 5 cases (%0.6) 3 times ve 2 cases (%0.2) 4 times.The mean follow up period was 15.4 ±19.2 months (6 -127 months) after contact lens fit. There was no complications encountered except 1 sterile infiltrate in 1 case. Conclusions: Rigid gas permeable contact lenses may be successfully fit in keratoconic eyes regardless of the keratoconus grade. Easy to fit and care, these lenses may be used for long term with no serious complications.

Benzer Tezler

  1. Patolojik meme başı akıntılarında galaktografik tetkikin tanıya katkısı

    Başlık çevirisi yok

    ŞERAFETTİN ARKUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Onkolojiİstanbul Üniversitesi

    Radyodiagnostik Ana Bilim Dalı

    PROF. DR. İLHAN KILIÇÖZLÜ

  2. İstanbul batı yakası vadilerinin şehirleşme süreci içinde ekolojik açıdan irdelenmesi

    Başlık çevirisi yok

    NAZLI YAZGAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    Peyzaj MimarlığıYıldız Teknik Üniversitesi

    Peyzaj Mimarlığı Ana Bilim Dalı

    PROF. DR. SEMRA ATABAY

  3. Meme başı akıntılarında galaktografik incelemenin değeri

    Başlık çevirisi yok

    REMİDE ARKUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1985

    Radyoloji ve Nükleer TıpEge Üniversitesi

    Radyoloji Ana Bilim Dalı

  4. Koroner arter ektazi ve/veya anevrizmalarının morbidite ve mortalite üzerine etkileri

    The natural history of coronary artery ectasias or aneurysms with or without obstructive coronary artery disease

    MURAT ÖZDAMAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2001

    KardiyolojiDokuz Eylül Üniversitesi

    Kardiyoloji Ana Bilim Dalı

    DOÇ.DR. ÖNDER KIRIMLI

  5. İzole koroner arter ektazisi saptanan hastalarda egzersizle iskemi sıklığı, iskeminin koroner anjiyografik bulgularla ilişkisi, beta bloker ve kalsiyum kanal blokerlerinin iskemi üzerine etkisi

    Frequency of ischemia with exercise in patients with isoled coronary artery ectatisia, relationship in between ischemia and coronary angiographic findings, effect of beta blockers and calcium canal blockers on ischemia

    GÜRHAN GÜNAY

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2001

    KardiyolojiSüleyman Demirel Üniversitesi

    Kardiyoloji Ana Bilim Dalı

    YRD. DOÇ. DR. AHMET ALTINBAŞ