Kuantum nokta modifiye elektrotlar kullanarak fotobiyosensör tasarımı ve akışa enjeksiyon siteminde uygulanması

Construction of photobiosensor using quantum dot modified electrodes and their applications in flow injection analysis

  1. Tez No: 457074
  2. Yazar: BENSU ERTEK
  3. Danışmanlar: PROF. DR. YUSUF DİLGİN
  4. Tez Türü: Doktora
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: Akış enjeksiyon sistemi, Biyosensörler, Fotoelektrokimyasal yöntemler, Glükozfosfat dehidrogenaz, Flow injection systems, Biosensors, Photoelectrochemical methods, Glucosephosphate dehydrogenases
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: Çanakkale Onsekiz Mart Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada yarı iletken kuantum nokta (Quantum dot, QD) nano parçacıklar (CdS/ZnS), çok duvarlı karbon nanotüp/camımsı karbon elektrot (GCE/MWCNT) ve kalem grafit elektrot (PGE) yüzeyine elektrokimyasal olarak biriktirilmiştir. Kuantum nokta modifiye elektrotların elektrokimyasal karakterizasyonu, Fe(CN)64-/3- içeren pH 7,0 fosfat tampon ortamında döngüsel voltammogramları ve impedans eğrileri kaydedilerek gerçekleştirilmiş ve elektrotların yüzey morfolojileri SEM görüntüleri kaydedilerek incelenmiştir. Modifiye elektrotlarla ilk olarak NADH'nin elektrokatalitik ve fotoelektrokatalitik yükseltgenmesi gerçekleştirilmiştir. Ardından glukoz dehidrogenaz (GDH) immobilize edilmiş QD modifiye PGE ve GCE/MWCNT kullanılarak akışa enjeksiyon analiz (Flow injection analysis, FIA) sisteminde glukoz biyosensörü için optimizasyon çalışmaları yapılmıştır. Glukoz ile NAD+ 'nın enzimatik tepkimesi sonucunda oluşan NADH'nin yükseltgenmesine ait akımlar izlenerek amperometrik ve fotoamperometrik glukoz biyosensörü FIA sisteminde geliştirilmiştir. Glukoz için doğrusal kalibrasyon aralığı, R2, LOD /LOQ değerleri QD modifiye PGE ve GCE/MWCNT için sırasıyla 0,2-0,8 mM (R2=0,9923), (LOD /LOQ 0,09 / 0,3 mM) ve 0,01-2,0 mM (R2=0,9971), (LOD /LOQ 0,006/0,02 mM) glukoz olarak bulunmuş ve yüzeyin ışıklandırılmasıyla akımın PGE için 2 kat, GCE/MWCNT için ise 3 kat arttığı tespit edilmiştir. Benzer sonuçlar etanol için alkol dehidrogenaz enzimi kullanılarak da elde edilmiş ve PGE ile GCE/MWCNT için sırasıyla 0,05-0,8 mM, (R2=0,9997), (LOD/LOQ 0,005/0,015 mM) ve 0,05-0,5 mM, (R2=0,9985), (LOD/LOQ 0,003/0,012 mM) etanol olarak hesaplanmıştır. Son olarak, girişim çalışmaları her iki enzim için ve gerçek örneklere uygulama çalışmaları glukoz dehidrogenaz için gerçekleştirilmiştir.

Özet (Çeviri)

In this study, semiconductor quantum dot (QD) nanoparticles (CdS/ZnS), were electrochemically deposited onto the surfaces of multiwalled carbon nanotube/glassy carbon electrode (GCE/MWCNT) and pencil graphite electrode (PGE). Electrochemical characterization of the QD modified electrodes was performed by recording the cyclic voltammograms and impedance spectra in pH 7.0 phosphate buffer solution containing Fe(CN)64-/3- and the surface morphologies of the electrodes were examined by recording SEM images. Initially the electrocatalytic and photoelectrocatalytic oxidation of NADH with the modified electrodes were carried out. Then, optimization studies for glucose biosensor using glucose dehydrogenase immobilized QD modified PGE and GCE/MWCNT were performed in FIA system. The oxidation of NADH which is produced by the enzymatic reaction of glucose and NAD+ was measured by the constructed amperometric and photoamperometric biosensors, which were developed in the FIA system. Linear calibration ranges, R2, LOD /LOQ results for glucose at modified PGE and GCE/MWCNT were found to be 0.2-0.8 mM (R2=0.9923), (LOD /LOQ 0.09 / 0.3 mM) and 0.01-2.0 mM (R2=0.9971), (LOD /LOQ 0.006/0.02 mM) glucose respectively and the measured current values increased about 2 fold for PGE and 3 fold for GCE/MWCNT by illumination of the electrode surfaces. Similar results were also obtained for ethanol biosensor based on alcohol dehydrogenase 0.05-0.8 mM, (R2=0.9997), (LOD/LOQ 0.005/0.015 mM) and 0.05-0.5 mM, (R2=0.9985), (LOD/LOQ 0.003/0.012 mM) were found for PGE and GCE/MWCNT respectively. Finally, the interference studies were carried out for both enzymes and applications with real samples were carried out for glucose dehydrogenase.

Benzer Tezler

  1. Ni-B ikili alaşım sisteminde Ni zengin bazı ara fazların manyetik özellikleri

    Magnetic properties of some Ni rich intermediate phases in Ni-B binary alloy system

    R.HALUK MUTLU

    Doktora

    Türkçe

    Türkçe

    1987

    Ankara Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Parçacık dedektörleri

    Başlık çevirisi yok

    EMEL BAŞARAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Çukurova Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  3. CO lazerleri

    CO lasers

    ŞEREF TURHAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  4. One-loop structure of non-line ar sigma models in symmetric spaces

    Başlık çevirisi yok

    YUSUF İPEKOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    1988

    Orta Doğu Teknik Üniversitesi

    Yükleniyor...

  5. Coulomb artı lineer potansiyelde kuantum durumlar

    Quantum states for coulomb plus linear potential

    MAHMUT EKEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Gazi Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...