Konik tip ı̇mplant-abutment bağlantısına sahip ı̇mplant sistemlerinin dinamik ve statik yükleme performansları

The dynamic and static load performance of implant systems with conical implant-abutment connections

  1. Tez No: 461143
  2. Yazar: MEHMET CAN BAŞGİL
  3. Danışmanlar: PROF. DR. CEM KURTOĞLU
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Çukurova Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 66

Özet

Son yıllarda diş eksikliklerinin tedavisinde implant tedavisi en çok kullanılan yöntemlerden biridir. İmplant-abutment ara yüzünün uyumu marjinal kemiğe yük iletilmesini azaltan en önemli faktörlerdendir ve internal konikal bağlantı tipi bunu en iyi sağlayan bağlantı tiplerinden biridir. Çalışmanın amacı; internal konikal implant-abutment bağlantısına sahip farklı marka implantların farklı dinamik yükleme döngülerinde kırılma dayanımlarını karşılaştırmaktır. Bu çalışmada internal konikal bağlantı tipine sahip Mode İmplant, DTI ve Implantium marka implantlar kullanılmıştır. Örnekler ISO 14801180 standartlarına uygun olacak şekilde 20 mm çapında 30 mm yüksekliğinde poliasetal blokların merkezine, implantların boylarından 3 mm kısa olacak şekilde yerleştirilmiştir. Markaların uygun abutmentları, markaların kendi vidaları ile uygun tork değerlerinde sıkılmıştır. Tüm abutmentların üzerine yarım kürenin merkezi ile poliasetal blok arasındaki uzaklık 11 mm olacak şekilde yarım küre şeklinde yükleme parçaları hazırlanmıştır. Üç farklı implant markasından 6 örneğe 5 mm/dk hız ile statik yükleme yapılmış ve bu kontrol grubu olarak değerlendirilmiştir (DTI-0, MODE-0, Imp-0). Statik yükleme sonucunda çıkan veriler doğrultusunda üç farklı implant markasından 3 örneğe dayanıklılık limiti testi yapılmış ve bunun sonucunda her implant markası için dinamik yüklemede kullanılacak maksimum yükler (DTI:200N, MODE:250N, Implantium:350N) belirlenmiştir. Dayanıklılık testi sonuçlarına göre seçilen yük değerlerinde her markadan 3 alt gruba (n=6) farklı döngülerde (250.000, 1.000.000, 2.500.000) 2 N ön yüklemeli 10 Hz frekansında, 30° açıyla dinamik yükleme yapılmış ve bu gruplar test grubu olarak değerlendirilmiştir (DTI-250, MODE-250, Imp-250, DTI-1000, MODE-1000, Imp-1000, DTI-2500, MODE-2500, Imp-2500). Ardından tüm test gruplarına statik yükleme yapılıp kontrol grubu ile karşılaştırılmıştır. Ayrıca her markadan 1 örneğe SEM analizi yapılmıştır. Veriler istatistiksel olarak incelenmiştir. Sonuç olarak implant markaları arasında dinamik yükleme sonucu kırılma dayanımlarında anlamlı farklılıklar bulunmuştur. Aynı marka implantların farklı dinamik yükleme döngülerinden sonraki kırılma dayanımı değerlerinde istatistiksel olarak anlamlı farklılık gözlenmemiştir.

Özet (Çeviri)

In recent years, dental implants have been used extensively in treating tooth losts. The stability of the implant-abutment interface is an important factor that influences load distribution to the marginal bone and internal conical connections have been introduced to provide the stability between implant and abutment. The aim of this study is to compare the fracture strengths of implants with internal conical connection after different dynamic loading cycles. Implants (n:27) were centrally embedded in a polyacetal cylinder with an inner diameter of 20 mm and a height of 30 mm. The implants were centered in the cylinder according to ISO 14801 as simulated bone loss of 3mm from the implant platform. All abutments were placed on the corresponding embedded implants, and the screws were tightened according to the manufacturers recommendations. One implant for each brand were separated for SEM analysis. A hemispherical loading device made of cobalt-chromium alloy was manufactured and seated onto the unmodified abutments. The distance from the center of the hemisphere to the top face of polyacetal cylinder was standardized at 11 mm. Three implants were used to determine the endurance limit. Then all brands were subdivided into four subgroups (n=6), 3 subgroups for dynamic + static loading (test groups; DTI-250, MODE-250, Imp-250, DTI-1000, MODE-1000, Imp-1000, DTI-2500, MODE-2500, Imp-2500), and 1 subgroup for static loading (control group; DTI-0, MODE-0, Imp-0,). The tests were performed by applying a compression load. Dynamic loadings were performed at 3 different cycles; 250.000, 1.000.000, 2.500.00 with 2N preload, with the endurance limit result loads as the upper load limit at frequency of 10 Hz for test groups (n=6). After dynamic loading, static loading was performed with a 5mm/min crosshead speed. Specimens were loaded until failure and all data's were recorded. Results were analyzed statisticaly. As a result, statistical differences were found between the implant brands fracture strenght results after dynamic loading. There is no statistical differences between the fracture strenght values of implants in the same brand after different dynamic loading cycles.

Benzer Tezler

  1. Vidasız konik kilit implant-dayanak bağlantılı kısa implantların farklı kuron/implant oranlarında stres dağılımının sonlu elemanlar analizi ile incelenmesi

    Evaluation of stress distribution of self-locking taper implant-abutment connected short implants at different CROWN/implant ratios by finite element analysis

    KÜBRA ŞİRİN GÜRSOY

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiMarmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. RİFAT GÖZNELİ

  2. BAHA® BA300 ile BAHA® BA400 işitme cihazı uygulanan hastalarda cerrahi ve işitme sonuçlarının karşılaştırılması

    Comparison between between BAHA® BA300 and BAHA® BA400 applied patients in terms of surgical and audiological results

    AYÇA BAŞKADEM YILMAZER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Kulak Burun ve Boğazİstanbul Üniversitesi

    Kulak Burun Boğaz Hastalıkları Ana Bilim Dalı

    PROF. DR. YAHYA GÜLDİKEN

  3. Agresif periodontitis hastalarında implant çevresi kemik seviyelerinin uzun dönem takibi

    Long-term evaluation of dental implants in patients treated for aggressive periodontitis

    IŞIL MİNOĞLU ŞAYLAN

    Doktora

    Türkçe

    Türkçe

    2010

    Diş Hekimliğiİstanbul Üniversitesi

    Periodontoloji Ana Bilim Dalı

    PROF. DR. ÖZEN TUNCER

  4. Farklı açılarla uygulanmış konik tek tip yivli ve çift tip yivli ortodontik mini implantların primer stabilitelerinin değerlendirilmesi

    Primary stability evaluation of mono and dual-thread miniscrews in different insertion angles

    KAĞAN LOSTUVALI

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiYeditepe Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. DERYA ÇAKAN

  5. Maksilla ve mandibulada yapılan dental implantların çevre anatomik yapılarla ilişkisinin konik ışınlı bilgisayarlı tomografide retrospektif olarak incelenmesi

    Retrospective examination of the relationship of dental implants in the maxilla and mandibular with surrounding anatomical structures in cone-beam computed tomography

    MEHMET EMİN DOĞAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiGaziantep Üniversitesi

    Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı

    DOÇ. DR. EDA DİDEM YALÇIN