Geri Dön

Pediatrik hastalarda laparoskopik apendektomi operasyonlarında pnömoperitonyumun ultrasonografik olarak değerlendirilen optik sinir kılıfı çapına etkisi

Pedi̇atri̇k hastalarda laparoskopi̇k apendektomi̇ operasyonlarinda pnömoperi̇tonyumun ultrasonografi̇k olarak değerlendi̇ri̇len opti̇k si̇ni̇r kilifi çapina etki̇si̇

  1. Tez No: 480894
  2. Yazar: FİRDEVS GONCA ŞAŞAL
  3. Danışmanlar: PROF. DR. NESLİHAN ALKIŞ, UZMAN AHMET ONAT BERMEDE, UZMAN MENEKŞE ÖZÇELİK
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
  6. Anahtar Kelimeler: Anestezi, Apendektomi, Cerrahi, Laparoskopi, Optik sinir, Pnömoperitonyum, Teşhis, Ultrasonografi, Çocuklar, İntrakraniyal basınç, Anesthesia, Appendectomy, Surgery, Laparoscopy, Optic nerve, Pneumoperitoneum, Diagnosis, Ultrasonography, Children, Intracranial pressure
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Giriş ve Amaç: Optik sinir duramater ile sarılı olarak kranyuma girer ve bu uzantının içerisinde BOS dolaşımı olmaktadır. Optik sinir kılıfı çapı ölçümü, kafa içi basıncı ile orantılıdır (4). Bu çalışmada, laparoskopik cerrahi geçiren hastalarda kafa içi basıncı değişkenliğinin, ultrasonografik olarak optik sinir kılıfı çapı ölçümü ile indirekt değerlendirilmesi amaçlanmıştır. Birincil amaç pnömoperitonyumun, ikincil amaç ise pozisyon değişikliğinin kafa içi basıncı üzerindeki etkisini araştırmaktır. Materyal ve Metod: Çalışmaya 5-12 yaş, ASA 1-2, 28 hasta alındı. 0,5 mg/kg p.o. midazolam premedikasyonu sonrası, rutin ASA monitörizasyonunu takiben 3 mg/kg propofol, 0.6 mg/kg roküronyum, 0.3-0.5 mg/kg remifentanil ile indüksiyon sağlandı. Anestezi idamesinde %40 O2 -%60 N2O karışımı içerisinde %2-3 sevofluran MAC 1,3 olacak şekilde uygulandı. Pnömoperitonyum sırasında intraabdominal basınç 12 mmHg olarak sağlandı. İndüksiyondan 3dk sonra (t0), insuflasyondan 5dk sonra (t1), trendelenburg + 15 derece sola yatırılma pozisyonuna getirildikten 5dk sonra (t2), insuflasyondan 15dk sonra (t3), insuflasyondan 30dk sonra (t4), desuflasyondan 5dk sonra (t5); iki göz için ayrı ayrı optik sinir kılıfı çapı ölçümleri yapılmıştır. 7.3-11.4 MHz frekanslı lineer prob ile optik sinirin göz küresinden çıktığı yerin 3 mm sonrasında transvers ölçüm yapılarak belirlenen değer, optik sinir kılıfı çapı olarak kaydedilmiştir. İstatistiksel analizler için; Tek Yönlü Varyans Analizi, Paired t- test ve Wilcoxon testleri kullanılmıştır. Bulgular: Optik sinir kılıfı çapı sağda; t0: 5,12 ± 0,49 mm, t1: 5,41 ± 0,49 mm, t2: 5,63 ± 0,58 mm (%95CI t0 ve t1 için: p<0.001, t1 ve t2 için p=0.001) solda; t0: 5,12 ± 0,46mm, t1: 5,42 ± 0,49 mm, t2:5,59 ± 0,46 mm (%95CI t0 ve t1 için p<0.001 t1 ve t2 için p=0.003) olarak saptanmış, sağda t0 ve t5 değerleri arasında anlamlı fark bulunamamıştır (t0: 5,12 ± 0,49 mm, t5: 5,28 ± 0,53 mm %95CI p=0.27). Solda t0 ve t5 değerleri karşılaştırıldığı zaman anlamlı fark tespit edilmiştir (t0: 5,12 ± 0,46 mm, t5: 5,30 ± 0,48 mm %95 CI p=0.019). Tartışma ve Sonuç: Optik sinir kılıfı çapı ölçümünün laparoskopik cerrahi sırasında kafa içi basıncı ölçümü için kullanılabileceği düşünülmektedir ve pnömoperitonyumun optik sinir kılıfı çapını arttırdığına dair çalışmalar bulunmaktadır (72,78). Pozisyonun etkisi ise tartışmalıdır (79, 80). Optik sinir kılıfı çapının eşik değeri konusunda kesin bir değer mevcut değildir. Çalışmamızda invaziv kafa içi basıncı karşılaştırılması yapılmamış olsa da ayrı ayrı insuflasyondan ve pozisyon değişikliğinin öncesinde ve sonrasında yapılan optik sinir kılıfı çapı ölçümlerinde anlamlı fark tespit edilmiştir ve kafa içi basıncının değişimi hakkında tahminde bulunulabilinir.

Özet (Çeviri)

Introduction and Purpose: Optic nerve enters into cranium with the dura mater wrapped around it and CSF circulation is within this extension. Measurement of optic nerve sheath diameter is proportional to intracranial pressure (4). The purpose of this study is to indirectly evaluate intracranial pressure variability in patients going through laparoscopic surgery via ultrasonographic measurement of optic nerve sheath diameter. The primary aim of this study is to observe the effect of pneumoperitoneum on the intracranial pressure, where the secondary goal is to investigate the effect of positional change on intracranial pressure. Materials and Methods: This study is compromised of the observation over 28 patients who vary between 5-12 years in age and classified ASA 1-2. After premedication with 0.5 mg/kg per oral midazolam, induction was achieved with 3 mg/kg propofol, 0.6 mg/kg rocuronium, 0.3-0.5 mcg/kg remifentanil following the ASA monitoring routine. Anesthesia maintenance was performed in the form of 2-3%sevoflurane (MAC 1.3) in a mixture of 40%O2-60%N2O. Intraabdominal pressure was maintained as12 mmHg during pneumoperitoneum. Optic nerve sheath diameters measured as 3 min after induction (t0), 5 min after insufflation (t1), 5 min after inserting trendelenburg and 15 degrees to the left side position (t2), 15 min after insufflation (t3), 30 min after insufflation (t4) and 5 min after exsufflation (t5). Optic nerve sheath diameters were measured for the two eyes separately. The value determined by transverse measurement on 3 mm distance to point the exit of the optic nerve with the linear probe of 7.3-11.4 MHz frequency was recorded as the optic nerve sheath diameter For statistical analysis, one way ANOVA, Paired t-test and Wilcoxon tests were applied. Results: Optic nerve sheath diameter was determined as t0: 5,12 ± 0,49 mm, t1: 5,41 ± 0,49 mm, t2: 5,63 ± 0,58 mm (%95CI t0 and t1 for: p<0.001, t1 ve t2 for p=0.001) on the right and t0: 5,12 ± 0,46mm, t1: 5,42 ± 0,49 mm, t2:5,59 ± 0,46 mm (%95CI t0 and t1 for p<0.001 t1 ve t2 for p=0.003) on the left. On the right, there was no significant difference between t0 and t5 (t0: 5,12 ± 0,49 mm, t5: 5,28 ± 0,53 mm %95CI p=0.27). On the left, a significant difference was found when t0 and t5 values were compared (t0: 5,12 ± 0,46 mm, t5: 5,30 ± 0,48 mm %95 CI p=0.019). Discussion and Conclusion: It is attainable that optic nerve sheath diameter measurement can be used for intracranial pressure measurement during laparoscopic surgery and there are also substantial studies that pneumoperitoneum increases the optic nerve sheath diameter (72,78). However the effect of the position is controversial (79,80). There is no precise value for the threshold value of the optic nerve sheath diameter. Although invasive intracranial pressures have not been compared in our study, a significant difference has been comfirmed in the optic nerve sheath diameter measurements performed separately, before and after the insufflation and the position changes where the change of intracranial pressure may be estimated.

Benzer Tezler

  1. Pediatrik laparoskopik apendektomi olgularında erektör spina plan bloğu ve quadratus lumborum plan bloğunun postoperatif ağrı ve analjezik ihtiyacı üzerine karşılaştırmalı etkisi: Prospektif randomize kontrollü çift kör çalışma

    Comparative effects of erector spinae plane block and quadratus lumborum plane block on postoperative pain and analgesic requirements in pediatric patients undergoing laparoscopic appendectomy: A prospective randomized controlled double-blind study

    ZEYCAN KAHYA OCAK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2026

    Anestezi ve ReanimasyonKütahya Sağlık Bilimleri Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ SÜLEYMAN CAMGÖZ

  2. Laparoskopik apendektomi geçiren çocuk hastalarda ağrı yönetiminde kuadratus lumborum bloğu ve rektus kılıf bloğunun karşılaştırılması

    Comparison of quadratuus lumborum block and rectus sheath block in pain management in children patients undergoing laparoscopic apendectomy

    AHMET ERTUĞRUL DEMİR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Anestezi ve ReanimasyonKahramanmaraş Sütçü İmam Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. GÖZEN ÖKSÜZ

  3. Çocukluk çağında apandisit tanısında hemogram parametrelerinin biyobelirteç olarak kullanılması

    Using hemogram parameters as biomarkers in the diagnosis of appendicitis in childhood

    FATİH SULTAN MEHMET KAVAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Çocuk CerrahisiKahramanmaraş Sütçü İmam Üniversitesi

    Çocuk Cerrahisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ AHMET GÖKHAN GÜLER

  4. Çocukluk çağında apandisit ön tanısı ile opere edilen hastaların verilerinin retrospektif analizi

    Retrospective analysis of data of patients operated with a preliminary diagnosis of appendicitis in childhood

    ALI EYVAZOV

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Çocuk CerrahisiMarmara Üniversitesi

    Çocuk Cerrahisi Ana Bilim Dalı

    DOÇ. DR. KIVILCIM KARADENİZ CERİT

  5. Çocuk yaş grubu hastalarda uygulanan rektus kılıf bloğunda yayılım mesafesinin retrospektif olarak değerlendirilmesi

    Başlık çevirisi yok

    HAZAR KÖKTEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Anestezi ve ReanimasyonHacettepe Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. FİLİZ ÜZÜMCÜGİL