Farklı protez temizleme solüsyonları ile muamele edilen akrilik kaide materyallerinin renk stabilitelerinin karşılaştırılması

Comparison of color stability of acrylic base materials treated with different denture cleansing agents

  1. Tez No: 491901
  2. Yazar: AHMET ŞANVER
  3. Danışmanlar: PROF. DR. FİLİZ KEYF
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental protezler, Diş renk değişikliği, Protez temizleyiciler, Renk dayanımı, Takma diş tabanları, Dental prosthesis, Tooth discoloration, Denture cleansers, Color stability, Denture bases
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Hareketli bölümlü veya tam protezler dişsiz hastaların rehabilitasyonunda uzun yıllardır kullanılmaktadır. Protezin estetiğinin uzun dönemli korunması için renk stabilitesi, dikkate alınması gereken önemli bir ölçüttür. Temizleyici maddeler veya yöntemler akriliklerin yüzey morfolojisini bozabilir veya akriliğin beyazlamasına, protezin metal bölümlerinin ise kararmasına veya korozyona uğramasına yol açabilir. Bu çalışmanın amacı, farklı protez temizleme solüsyonlarıyla muamele edilen akrilik kaide materyallerinin, renk stabilitelerinin in vitro koşullarda karşılaştırılmasıdır. Bu amaçla çalışmada dört adet ısı ile polimerize olan (meliodent heat cure, paladent 20, procryla ve rodex), dört adet kimyasal yolla polimerize olan (meliodent rapid repair, paladent rr, panacryl ve takilon) toplam sekiz akrilik kaide materyali kullanılarak 2 mm kalınlığa ve 15 mm çapa sahip disk şeklinde, her bir akrilik markasından 40 adet olmak üzere toplamda 320 adet örnek hazırlanmıştır. Protez kaidesini taklit etmek amacıyla örneklerin sadece tek yüzü polisajlanmıştır. Her akrilik markasından 10'ar örnek üç farklı protez temizleme solüsyonunda üretici firma talimatlarına uygun sürede bekletilmiştir. Bu işlem 90 gün süre ile her gün için tekrar edilmiştir. Her markadan 10'ar örnek ise kontrol grubu olan suda bekletilmiştir. Doksan günün sonunda spektrofotometre cihazı kullanılarak örneklerin renk ölçümü yapılmıştır. CIE Lab renk sistemine göre ΔE değerleri hesaplanmıştır. İstatistiksel analizler için IBM SPSS Statistics 23.0 paket programı kullanılmıştır. Sonuç olarak tüm örneklerde renk değişimi gözlenmiştir. Protefix solüsyonunda bekletilen ısı ile polimerize olan Paladent akrilik materyalinde ve %1'lik sodyum hipoklorit solüsyonunda bekletilen ısı ile polimerize olan Rodex ve kimyasal yolla polimerize olan Takilon akrilik materyallerinde renk değişimi daha fazla olmuştur. Bu değişim kontrol grubu olan su ile karşılaştırıldığında istatistiksel olarak anlamlı bulunmuştur. Örneklerin büyük çoğunluğunda polisajsız yüzeylerde renk değişimi daha fazladır. Isı ile polimerize olan Meliodent ve kimyasal yolla polimerize olan Takilon materyallerinin Protefix solüsyonunda bekleyen örneklerinde polisajsız yüzeylerde, polisajlı yüzeylere göre anlamlı derecede daha fazla renklenme görülmüştür. Diğer akrilik materyallerin polisajlı ve polisajsız yüzeyleri arasındaki renk değişimi istatistiksel olarak anlamlı bulunmamıştır.

Özet (Çeviri)

Removable partial or full dentures have been used for many years for the rehabilitation of edentulous patients. Color stability is an important measurement to consider for long-term protection of the aesthetic of the denture. Cleansing agents or methods may disrupt the surface morphology of the acrylics or cause whitening of the acrylic and corrosion or black staining on the metal parts of the denture. The purpose of this study is to compare the color stability of acrylic base materials treated with different denture cleansing solutions under in vitro conditions. For this purpose, 40 acrylic discs from eight brands, for a total of 320 specimens were prepared, each with a diameter of 15 mm and thickness of 2 mm treated with four thermally polymerized (meliodent heat cure, paladent 20, procryla and rodex) and four chemically polymerized (meliodent rapid repair, paladent rr, panacryl and takilon) acrylic base materials. Only one side of the specimens was polished to imitate the denture base. Ten samples from each acrylic brand were stored in three different denture cleaning solutions in accordance with the manufacturer's instructions. This process was repeated every day for 90 days long. 10 samples from each brand were kept in the control group water. At the end of 90 days, the color of the samples was measured using a spectrophotometer. ΔE values were calculated according to the CIE Lab color system. For statistical analysis, IBM SPSS Statistics 23.0 was used. As a result, the color change was observed in all samples. The color change in the chemically polymerized Takilon acrylic materials and thermally polymerized Rodex with the 1% sodium hypochlorite solution and thermally polymerized Paladent acrylic materials with the Protefix solution was found statistically significant when compared to control group in water. The color change on the unpolished surface was more in the vast majority of samples. Heat-polymerized Meliodent and chemically polymerized Takilon materials kept in Protefix solution showed significantly more coloring on non-polished surfaces than polished surfaces. The color change between the polished and non-polished surfaces of other acrylic materials was not found statistically significant.

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  2. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    ÜrolojiGazi Üniversitesi

    Üroloji Ana Bilim Dalı

  3. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Besin Hijyeni ve Teknolojisiİstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    DOÇ. DR. TÜRKAN KUTLUAY