Geri Dön

Evaluation of internal adaptation of crowns fabricated with three different zirconia CAD/CAM materials

Üç farkli CAD/CAM ile üretilen zirkonya kuronların iç adaptasyonunun değerlendirilmesi

  1. Tez No: 591995
  2. Yazar: RİM TEMİZKAN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ CEREN KÜÇÜK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2019
  8. Dil: İngilizce
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 77

Özet

Amaç: Bu çalısmanın amacı CAD-CAM sistemi ile üretilen monolitik zirkonyum kuron restorasyonları (GC Initial, GC Europe, Leuven, Belgium ve InCoris TZI, Sirona Dental Systems, Bensheim, Germany) ve veneerlenmiş zirkonyum altyapılı kuron restorasyonlarının (InCoris ZI, Sirona Dental Systems, Bensheim, Germany) iç uyumlarının konvansiyonel metal seramik kuron restorasyonlarıyla karşılaştırmalı olarak değerlendirilmesidir. Gereç ve Yöntem: 92 adet çekilmiş molar diş seçildi ve temizlendi. Dişler rastgele 4 gruba ayrıldı Metal Seramik kuron restorasyonları (n = 24); GC initial Zr monolitik zirkonyum kuron restorasyonları (n = 24); InCoris TZI monolitik zirkonyum kuron restorasyonları (n = 24); düşük ısı porseleni ile venerlenmiş InCoris ZI zirkonyum altyapılı kuron restorasyonları (n = 24). Dişler standart prosedürlere uygun olarak prepare edildi. Prepare edilen dişlerin ölçüsü alındı ve alçı modeller elde edildi. Metal-seramik kuronlar konvensiyonel teknikle üretildi. Tüm zirkonyum gruplarin modelleri Sirona inEos X5 kullanılarak tarandı. Zirkonyum kuronlar ve altyapılar, Cerec inLab MC X5 sisteminde tasarlanıp üretildi. Silikon replika tekniği iç uyumu ölçmek için kullanıldı. Her replika cerrahi bir bıçak kullanılarak mezio-distal ve bukko-lingual olarak kesildi. Her örnek için 20 adet ölçüm 20X büyütme ile ışık mikroskobu altında alındı. Referans noktaları marjinal (M), internal marjinal (IM), aksyial (Ax1, Ax2), ve okluzal (O) olarak belirlendi. Her referans noktası için ortalama değerler hesaplandı. Tüm veriler SPSS programi ile istatistiksel olarak analiz edildi. Bulgular: Gruplar arasında ortalama marjinal ve internal açıklıklar istatistiksel olarak anlamlı derecede farklı bulundu. Sonuç: Bu in vitro araştırmasının sınırlamaları dahilinde, zirkonyum restorasyonları klinik olarak kabul edilebilir iç adaptasyon sonuçları göstermiştir.

Özet (Çeviri)

Aim: The aim of this study is to evaluate the internal fit of crowns fabricated with three different CAD-CAM zirconia materials; two monolithic zirconia material GC initial (GC Europe, Leuven, Belgium), InCoris TZI (Sirona Dental Systems, Bensheim, Germany) and one veneered zirconia copings InCoris ZI (Sirona Dental Systems, Bensheim, Germany) in comparison with conventional metal-ceramic crowns. Materials and Methods: Ninety-six extracted molars (n=96) were selected. Teeth were randomly divided into 4 groups (n=24): Metal Ceramic crowns (Control group); GC Initial Zr monolithic zirconia crowns; InCoris TZI monolithic zirconia crowns; InCoris ZI zirconia core veneered with a low-fusing glass-ceramic. Tooth preparation was carried out according to the standardized protocols. Impressions were taken and casts were poured. Digital impressions for the other casts were acquired. Zirconia crowns and cores were milled using CAD-CAM manufacturing system Cerec inLab MC X5. Silicone replicas were fabricated and sectioned bucco-lingually and mesio-distally into 4 parts using a surgical blade. A total of twenty points were recorded for every tooth under light microscope at 20x magnifications. The reference points were set at the marginal (M), internal marginal (IM), axial (Ax1, Ax2), and occlusal (O) areas, and the mean values were calculated for each reference point. All data were statistically analyzed using SPSS software. Results: There was significant differences found in the mean of marginal and internal discrepancies between the groups. Conclusion: Within the limitations of this in this investigation, the three tested CAD/CAM Zirconia materials showed clinically acceptable marginal adaptation.

Benzer Tezler

  1. Farklı CAD/CAM materyalleriyle üretilen anterior kuronların marjinal ve internal uyumlarının In-Vitro olarak karşılaştırılması

    In Vitro evaluation of marginal and internal adaptation of different CAD/CAM materials

    MARUF HALMEDOV

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiMarmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. ERKUT KAHRAMANOĞLU

  2. In-vitro evaluation of marginal adaptation of crown restorations fabricated from different hybrid ceramic materials

    Farklı hibrit seramik materyalleri ile hazırlanan kron restorasyonlarının marjinal uyumlarının in vitro olarak değerlendirilmesi

    EMCED ŞAAR

    Yüksek Lisans

    İngilizce

    İngilizce

    2019

    Diş HekimliğiMarmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. BUKET EVREN

  3. 3 farklı yöntemle elde edilmiş metal altyapıların porselen ile bağlantısının değerlendirilmesi, porselen fırınlama sikluslarının kronun marjinal ve iç uyumuna etkisinin in-vitro olarak karşılaştırılması

    Evaluation of the porcelain bonding of metal substructures fabricated by 3 different manufacturing techniques, in-vitro comparison of the effect of porcelain firing cycles on internal and marginal fit of crowns

    NAZLI YEŞİLYURT AYDIN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiÇukurova Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. YURDANUR UÇAR

  4. Minimal invaziv yöntemlerle hazırlanan porselen laminaların dişe uyumlarının incelenmesi ve klinik takibi

    Clinical internal and marginal gap of porcelain laminate veneers with minimal tooth preparation and without tooth preparation and 2-year clinical evaluation

    İREM KARAGÖZOĞLU

    Doktora

    Türkçe

    Türkçe

    2015

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SUNA TOKSAVUL

  5. CAD/CAM ve preslenebilir tüm seramik sistemleri ile yapılan kronların marjinal ve internal uyumlarının in vivo ve in vitro karşılaştırmalı olarak araştırılması

    In vivo and ın vitro evaluation of marginal and ınternal fit of all-ceramic crowns fabricated with cad/cam and pressable systems

    ASLI AKIN

    Doktora

    Türkçe

    Türkçe

    2011

    Diş HekimliğiEge Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SUNA TOKSAVUL