Geri Dön

Krem formülasyonundaki farmasötik ürünlerde etken madde, safsızlık ve yağ asiti esterlerinin yüksek basınçlı sıvı kromatografisi ile eşzamanlı tayini

Simultaneous determination of active substance, impurity and fatty acid esters in cream formulation pharmaceutical products by high pressure liquid chromatography

  1. Tez No: 602400
  2. Yazar: MEHMET ÇALIKOĞLU
  3. Danışmanlar: DOÇ. DR. AYSEL BERKKAN
  4. Tez Türü: Doktora
  5. Konular: Eczacılık ve Farmakoloji, Pharmacy and Pharmacology
  6. Anahtar Kelimeler: Benzil nikotinat, Farmasötikler, Kromatografi-yüksek basınçlı-sıvı, Yağ asitleri, İlaç formülleri, Benzyl nicotinate, Pharmaceuticals, Chromatography-high pressure-liquid, Fatty acids, Formularies
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Analitik Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Farmasötik kalite kontrol laboratuvarlarında yarı-katı ürünler için hızlı, duyarlı ve güvenilir test metotlarına ihtiyaç duyulması, bu çalışmanın ana amacını oluşturmuştur. Bu sebeple etken madde (etofenamat, benzil nikotinat), koruyucu (benzil alkol), safsızlık (flufenamik asit, dekarboksil, dietilenglikol diflufenamat, flufenamik asit bütilester, benzaldehit) ve yağ asidi esterleri (etofenamat miristat, etofenamat palmitat, etofenamat stearat) için eş zamanlı kantitatif tayin imkanı sağlayan yöntem geliştirilmiştir. 10 mM sodyum asetat/metanol çözeltisi hareketli faz olarak gradient akış programında kullanılarak 11 analit tayin edilmiştir. HPLC cihazında sabit faz olarak C8 Hypersil 125 mm x 4,6 mm 5µm analitik kolonu kulanılmıştır. Kolon sıcaklığı 40 °C, akış hızı 2,0 mL/dakika ve enjeksiyon hacmi 10 µL'dir. Numuneler için çözücü olarak metanol kullanılmıştır. Dalga boyu t= 0 için 258 nm'ye ayarlanmış ve gradient elüsyonun 9,1 ci dakikasında 286 nm'ye değiştirilmiştir. Her bir enjeksiyon için kromatografik süre 15 dakikadır. ICH Q2 (R1) rehberi referans alınarak seçicilik, doğrusallık, kesinlik, doğruluk, teşhis limiti ve tayin alt limiti parametreleri hesaplanarak analitik yöntem valide edilmiş ve ticari numuneler için yöntemin uygunluğu istatistiksel olarak ispatlanmıştır. Yöntem kesinliği için bağıl standart sapma sonuçları %0,24 - 2,02 arasında olup analitlere ait ortalama geri kazanım sonuçları %91,5 – 102,6 arasında tespit edilmiştir. Tüm validasyon sonuçları değerlendirildiğinde; hızlı, seçici, kesinliği ve duyarlılığı yüksek bir tayin yöntemi geliştirilmiştir. Geliştirilen yöntem, etofenamat, benzil alkol ve benzil nikotinat içeren krem formülasyonundaki farmasötik preparatların rutin kalite kontrol analizlerinde kolay, hızlı, seçici ve duyarlı bir yöntemdir.

Özet (Çeviri)

The purpose of this study is the necessity for rapid, sensvitive, and reliable test methods for semi-solid products in pharmaceutical quality control laboratories. Therefore, a method was developed for simultaneous determination of active substance (etofenamate, benzyl nicotinate), preservative (benzyl alcohol), impurity (flufenamic acid, decarboxy, diethyleneglycol diflufenamate, flufenamic acid buthylester, benzaldehyde) and fatty acid esters (etofenamate myristate, etofenamate palmitate, etofenamate stearate). 11 analytes were determined by using 10 mM sodium acetate/methanol as mobile phase with gradient flow system. C8 Hypersil 125 mm x 4,6 mm 5µm analytical column was used as stationary phase in HPLC device. The column temperature was 40 °C, flow rate was 2.0 mL/minute and injection volume was 10µL. Methanol was used as solvent for samples. The wavelength was set at 258 nm for t= 0 and changed to 286 nm at the 9.1th min of gradient elution. Run time for each injection is 15 minutes. Selectivity, linearity, precision, accuracy, detection limit, quantitation limit parameters were calculated and analytical method was validated with reference to ICH Q2 (R1) guideline. The suitability of method for commercial samples was proved statistically. Relative standard deviation results are between 0,24 – 2,02% for method precision and average recovery results for analytes are between 91,5 – 102,6%. Based on obtained validation results; a rapid, selective, precise and sensitive determination method was generated. The developed method is simple, rapid and sensitive for routine quality control analysis of pharmaceutical products in cream formulation which contains etofenamate, benzyl alcohol and benzyl nicotinate.

Benzer Tezler

  1. Krem tip eritme peynir imalat teknolojisi

    Başlık çevirisi yok

    GÜL FİGEN AR

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Ege Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Bazı antiseptik maddelerin deri üzerinden rezorbsiyonunun in vitro olarak araştırılması

    Başlık çevirisi yok

    MESUDE UYGUN DERE

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Marmara Üniversitesi

    Farmasötik Teknoloji Ana Bilim Dalı

    Yükleniyor...

  3. Çayözü-Çakırtarla (Divriği) yöresinin jeolojisi

    Başlık çevirisi yok

    FEDA ARAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Cumhuriyet Üniversitesi

    Yükleniyor...

  4. Eksternal ajanların sekonder yara iyileşmesine etkisi

    Başlık çevirisi yok

    ALEV EKEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1989

    Erciyes Üniversitesi

    Dermatoloji Ana Bilim Dalı

    Yükleniyor...

  5. Pendik çanak çömleği

    Başlık çevirisi yok

    NİLGÜN ÖZBAŞARAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    İstanbul Üniversitesi

    Yükleniyor...