Farklı çalışma şartlarında CO2 soğutucu akışkanlı ısı pompası performansının teorik ve deneysel olarak incelenmesi

Experimental and theoretical and investigation of CO2 refrigerant heat pump performance in different operating conditions

  1. Tez No: 615396
  2. Yazar: BAHRİ AKSU
  3. Danışmanlar: PROF. DR. HÜSEYİN KURT
  4. Tez Türü: Doktora
  5. Konular: Enerji, Makine Mühendisliği, Energy, Mechanical Engineering
  6. Anahtar Kelimeler: Isı pompası, CO2 soğutucu akıĢkan, Enerji Analizi, Ekserji Analizi, Termoekonomik Analiz, MOPSA, Toprak kaynaklı ısı pompası, Heat pump, CO2 Refregirant, Energy Analysis, Exergy Analysis, Thermoeconomic Analysis, MOPSA, Ground source heat pump
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Karabük Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, farklı çalışma şartlarında CO2 (R744) soğutucu akışkanlı buhar sıkıştırmalı sudan suya bir ısı pompasının performansı subkritik bölgede deneysel ve teorik olarak incelenmiştir. Sudan suya bir ısı pompası sistemi tasarlanarak, kurulan deney düzeneğinde farklı kondenser ve evaporatör su giriş sıcaklıkları ile farklı kondenser ve evaporatör su debilerinde iki farklı durum için deneyler gerçekleştirilmiştir. Birinci grup deneylerde; evaporatör su debisi 500 lt/h değerinde sabit tutularak, kondenser ve evaporatör giriş suyu sıcaklıkları 11 °C, 13 °C ve 15 °C değerinde değiştirilerek, 600 lt/h, 700 lt/h ve 800 lt/h değerlerindeki farklı kondenser su debilerinin ısı pompası performansı üzerindeki etkileri gözlemlenmiştir. İkinci grup deneylerde ise; kondenser su debisi 500 l/h değerinde sabit tutularak, kondenser ve evaporatör giriş suyu sıcaklıkları 11 °C, 13 °C ve 15 °C değerlerinde değiştirilerek 600 lt/h, 700 lt/h ve 800 lt/h değerlerindeki farklı evaporatör su debilerinin ısı pompası performansına etkisi gözlemlenmiştir. Deneylerde; sistem üzerinde basınç, sıcaklık, debi ve güç gibi parametreler ölçülmüştür. Deneysel ölçümlerden elde edilen veriler kullanılarak ısı pompasının enerji, ekserji ve termoekonomik analizleri yapılmıştır. Enerji analizi sonuçlarına göre birinci grup deneylerde ısı pompasının ısıtma tesir katsayısı (COPHP) değerinin 3,75 ile 4,049 aralığında, ikinci grup deneylerde ise 3,192 ile 3,75 aralığında değiştiği görülmüştür. Ekserji analizinden elde edilen sonuçlardan, ısı pompası ekserji veriminin birinci grup deneylerde 0,403 ile 0,428 aralığında, ikinci grup deneylerde ise 0,394 ile 0,416 aralığında değiştiği belirlenmiştir. Isı pompasının termoekonomik analizi MOPSA metoduna göre yapılmış, kondenserden suya aktarılan birim kW ısı enerjisi başına harcanan mali değerin; birinci grup deneylerde 0,153 $/kW ile 0,163 $/kW aralığında, ikinci grup deneylerde ise 0,160 $/kW ile 0,165 $/kW aralığında değiştiği tespit edilmiştir.

Özet (Çeviri)

In this study, the performance of water to water vapor compression heat pump which was used CO2 (R744) as a refrigerant was investigated experimentally and theoretically under different operating conditions in the subcritical region. By designing a water-to-water heat pump system, experiments were carried out for two different situations in different condenser and evaporator water inlet temperatures and different condenser and evaporator water flow rates. In the first group of experiments, by keeping the evaporator water flow rate constant at 500 lt/h, the condenser and evaporator inlet water temperatures have been changed as 11 ° C, 13 ° C and 15 ° C, then the performance of heat pump have been observed under different condenser water flow rates of 600 lt/h, 700 lt/h and 800 lt/h. In the second group of experiments, by keeping the condenser water flow rate constant at 500 lt/h, the condenser and evaporator inlet water temperatures have been changed as 11 ° C, 13 ° C and 15 ° C, then the performance of heat pump have been observed under different evaporator water flow rates of 600 lt/h, 700 lt/h and 800 lt/h. In experiments; parameters such as pressure, temperature, flow rate and power consumption have been measured on the system. Energy, exergy and thermoeconomic analyzes of the heat pump have been made using the data obtained from the experimental measurements. According to the results of the energy analysis, it was observed that the coefficient of performance of the heat pump (COPHP) in the first group of experiments ranged from 3.75 to 4.049, and in the second group of experiments ranged from 3.192 to 3.75. From the results obtained from the exergy analysis, it was determined that the heat pump exergy efficiency ranged between 0.403 and 0.428 in the first group of experiments, and between 0.339 and 0.416 in the second group of experiments. The thermoeconomic analysis of heat pump was made with the MOPSA method, the financial value spent per unit kW of heat energy transferred from the condenser to the water; In the first group of experiments, it was found that it ranged from $ 0.153 / kW to $ 0.163 / kW, and in the second group of experiments ranged from $ 0.16 / kW to $ 0.165 / kW.

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  2. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  3. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Üroloji Ana Bilim Dalı

    Yükleniyor...

  4. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    Yükleniyor...