Geri Dön

Bilgisayarlı tomografide iteratif rekonstrüksiyon algoritmalarının görüntü kalitesi ve hasta dozu üzerindeki etkileri

Effects of iterative reconstruction on image quality and patient dose in computed tomography

  1. Tez No: 618017
  2. Yazar: ELİF ECEM BELİVERMİŞ
  3. Danışmanlar: PROF. DR. ŞERİFE İPEK KARAASLAN, DR. TÜRKAY TOKLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: İteratif Rekonstrüksiyon, Bilgisayarlı Tomografide İteratif Rekonstrüksiyon Algoritmaları, Bilgisayarlı Tomografi, Iterative Reconstruction, Iterative Reconstruction Algorithms, Computed Tomography
  7. Yıl: 2019
  8. Dil: Türkçe
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 92

Özet

Bu tez çalışmasında bilgisayarlı tomografide iteratif rekonstrüksiyon algoritmalarının görüntü kalitesi ve hasta dozu üzerindeki etkileri incelenmiştir.Çalışmamızda Yeditepe Üniversitesi İhtisas Hastanesindeki PET/CT tomografi cihazı kullanılmıştır. Bu sistemde hem filtrelenmemiş geriye projeksiyon hem de İteratif Rekonstrüksiyonalgoritmasıyla tomografi oluşturma olanağı bulunmaktadır.Farklı ışınlama parametrelerinde bilgisayarlı tomografi doz indeksi (CTDI) değerleri, CTDI fantomu ve 10cm uzunluğunda kalem tipi iyon odası kullanılmıştır.Görüntü kalitesi değerlendirmesi için Cathpan 600 fantomu kullanılmıştır. Görüntü kalite parametrelerinin değerlendirmeleri ücretsiz yazılımlardan olan IMAGE J ve IQ WORK yazılımları kullanılarak gerçekleştirilmiştir.Tomografi sistemi ışınlama parametreleri 120 kVp ve üç farklı mA değerinde yapılmıştır.Bu farklı mA değerleri için CTDI değerleri ölçülerek ve sistemin verdiği değerler ile karşılaştırılmıştır.Hem 2,5 mm hem de 5mm tomografik kesitler elde edilmiştir.Catphan 600 fantomuna ait standard ve detay filtreleri kullanılarak filtrelenmiş geriye projeksiyon ve iteratif rekonstrüksiyonparametreleri 20, 40, 60, 80 ve 100 değerlerinde kullanılarak iteratif olarak elde edilmiştir. Catphan 600 fantomu görüntülerinden tüm Rekonstrüksiyon yöntemleri için CNR, SNR, MTF ve Homogeneity gibi görüntü kalitesi parametreleri değerlendirilmiştir. Son olarak görüntü kalitesini koruyarak iteratif yöntemlerle doz azaltılabileceği belirlenerek ve kliniğe bu şartlarda çekim yapılması önerilmiştir. Yeditepe Üniversitesi İhtisas Hastanesi Nükleer Tıp kliniğinde bulunan PET/CT cihazının CT kompenentinde farklı doz seviyelerinde kantatif görüntü kalitesi parametreleri değerlendirilerek aynı görüntü kalitesinde daha düşük ışınlama şartlarında tomografinin çekilmesi sağlanmıştır.

Özet (Çeviri)

In this thesis, the effects of iterative reconstruction algorithms on image quality and patient dose were investigated. PET / CT tomography device in Yeditepe University Specialized Hospital was used. In the abovementioned system, both unfiltered back projection and iterative reconstruction algorithm can create tomography. Computed tomography dose index (CTDI) values, CTDI phantom, and 10cm pen-type ion chamber were used for different irradiation parameters. Cathpan 600 phantom was chosen for image quality evaluation. Evaluation of image quality parameters (free software) was performed using IMAGE J and IQ WORK software. The irradiation parameters of the tomography system were 120 kVp and chosen three different mA values. CTDI values for these different mA values were measured and compared with the values given by the system. Both 2,5 mm and 5 mm tomographic sections were obtained. Filtered back projection and iterative reconstruction parameters were obtained at 20,40,60,80 and 100 values by using standard and detail filters of Catphan 600 phantom. Image quality parameters such as CNR, SNR, MTF, and homogeneity were evaluated for all reconstruction methods from Catphan 600 phantom images. Finally, iterative methods can be used to reduce the dose while preserving the image quality and it is also recommended to take the clinic under these conditions. Different quantitative image quality parameters at different dose levels were evaluated by the CT component of the PET / CT in the Nuclear Medicine Department of Yeditepe University Specialized Hospital besides obtained tomography kept the irradiation conditions low with the same image quality.

Benzer Tezler

  1. Bilgisayarlı tomografide iteratif rekonstrüksiyon modellerinin saçılan radyasyona etkileri

    The effects of iterative reconstruction models on secondary radiation in computed tomography

    MURAT DÜNDAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Radyoloji ve Nükleer TıpEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    PROF. DR. ELÇİN EKDAL KARALI

  2. Bilgisayarlı tomografide hasta dozunu azaltmak için kullanılan bizmut koruyucuların hasta dozu ve görüntü kalitesine etkisi

    The effect of bismuth shi̇elds used to reduce patient dose in computed tomography on patient dosage and image quality

    YUSUF LEVENT ERTOKTAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Radyasyon Onkolojisiİstanbul Aydın Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FÜSUN ÇETİN

  3. Bilgisayarlı tomografi anjiyografide derin öğrenme rekonstrüksiyon yönteminin diğer rekonstrüksiyon yöntemleri ile karşılaştırılması

    Comparison of deep learning reconstruction method with other reconstruction methods in computed tomography angiography

    MUHAMMET BERKAY SEVİNÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Radyoloji ve Nükleer Tıpİstanbul Yeni Yüzyıl Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ SEVİL ÖZER

  4. İteratif rekonstrüksiyonun koroner bilgisayarlı tomografi anjiyografi tetkikinde görüntü kalitesine ve değerlendirilebilen koroner arter segment sayısına etkisinin araştırılması

    The assessment of iterative reconstruction impact on diagnostic image quality, as well as demonstration of the entire coronary artery segments in coronary CT angiography, Hacettepe University, Faculty of Medicine, Department of radiology

    EMIL ABDULLAYEV

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2017

    Radyoloji ve Nükleer TıpHacettepe Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. TUNCAY HAZIROLAN

  5. Bilgisayarlı tomografi ile elde edilen volumetrik verinin işlenerek üç boyutlu görüntüye dönüştürülmesi

    Transformation of the volumetric data acquired through computerized tomography to three dimensional image by processing

    FURKAN NUR DENİZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    Elektrik ve Elektronik Mühendisliğiİnönü Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MEHMET EMİN TAĞLUK