Bilgisayarlı tomografide iteratif rekonstrüksiyon algoritmalarının görüntü kalitesi ve hasta dozu üzerindeki etkileri
Effects of iterative reconstruction on image quality and patient dose in computed tomography
- Tez No: 618017
- Danışmanlar: PROF. DR. ŞERİFE İPEK KARAASLAN, DR. TÜRKAY TOKLU
- Tez Türü: Yüksek Lisans
- Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
- Anahtar Kelimeler: İteratif Rekonstrüksiyon, Bilgisayarlı Tomografide İteratif Rekonstrüksiyon Algoritmaları, Bilgisayarlı Tomografi, Algoritmalar, Görüntü kalitesi, Tomografi-x ışınlı-bilgisayarlı, İteratif yöntemler, Iterative Reconstruction, Iterative Reconstruction Algorithms, Computed Tomography, Algorithms, Image quality, Tomography-x ray-computed, Iterative methods
- Yıl: 2019
- Dil: Türkçe
- Üniversite: Yeditepe Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu tez çalışmasında bilgisayarlı tomografide iteratif rekonstrüksiyon algoritmalarının görüntü kalitesi ve hasta dozu üzerindeki etkileri incelenmiştir.Çalışmamızda Yeditepe Üniversitesi İhtisas Hastanesindeki PET/CT tomografi cihazı kullanılmıştır. Bu sistemde hem filtrelenmemiş geriye projeksiyon hem de İteratif Rekonstrüksiyonalgoritmasıyla tomografi oluşturma olanağı bulunmaktadır.Farklı ışınlama parametrelerinde bilgisayarlı tomografi doz indeksi (CTDI) değerleri, CTDI fantomu ve 10cm uzunluğunda kalem tipi iyon odası kullanılmıştır.Görüntü kalitesi değerlendirmesi için Cathpan 600 fantomu kullanılmıştır. Görüntü kalite parametrelerinin değerlendirmeleri ücretsiz yazılımlardan olan IMAGE J ve IQ WORK yazılımları kullanılarak gerçekleştirilmiştir.Tomografi sistemi ışınlama parametreleri 120 kVp ve üç farklı mA değerinde yapılmıştır.Bu farklı mA değerleri için CTDI değerleri ölçülerek ve sistemin verdiği değerler ile karşılaştırılmıştır.Hem 2,5 mm hem de 5mm tomografik kesitler elde edilmiştir.Catphan 600 fantomuna ait standard ve detay filtreleri kullanılarak filtrelenmiş geriye projeksiyon ve iteratif rekonstrüksiyonparametreleri 20, 40, 60, 80 ve 100 değerlerinde kullanılarak iteratif olarak elde edilmiştir. Catphan 600 fantomu görüntülerinden tüm Rekonstrüksiyon yöntemleri için CNR, SNR, MTF ve Homogeneity gibi görüntü kalitesi parametreleri değerlendirilmiştir. Son olarak görüntü kalitesini koruyarak iteratif yöntemlerle doz azaltılabileceği belirlenerek ve kliniğe bu şartlarda çekim yapılması önerilmiştir. Yeditepe Üniversitesi İhtisas Hastanesi Nükleer Tıp kliniğinde bulunan PET/CT cihazının CT kompenentinde farklı doz seviyelerinde kantatif görüntü kalitesi parametreleri değerlendirilerek aynı görüntü kalitesinde daha düşük ışınlama şartlarında tomografinin çekilmesi sağlanmıştır.
Özet (Çeviri)
In this thesis, the effects of iterative reconstruction algorithms on image quality and patient dose were investigated. PET / CT tomography device in Yeditepe University Specialized Hospital was used. In the abovementioned system, both unfiltered back projection and iterative reconstruction algorithm can create tomography. Computed tomography dose index (CTDI) values, CTDI phantom, and 10cm pen-type ion chamber were used for different irradiation parameters. Cathpan 600 phantom was chosen for image quality evaluation. Evaluation of image quality parameters (free software) was performed using IMAGE J and IQ WORK software. The irradiation parameters of the tomography system were 120 kVp and chosen three different mA values. CTDI values for these different mA values were measured and compared with the values given by the system. Both 2,5 mm and 5 mm tomographic sections were obtained. Filtered back projection and iterative reconstruction parameters were obtained at 20,40,60,80 and 100 values by using standard and detail filters of Catphan 600 phantom. Image quality parameters such as CNR, SNR, MTF, and homogeneity were evaluated for all reconstruction methods from Catphan 600 phantom images. Finally, iterative methods can be used to reduce the dose while preserving the image quality and it is also recommended to take the clinic under these conditions. Different quantitative image quality parameters at different dose levels were evaluated by the CT component of the PET / CT in the Nuclear Medicine Department of Yeditepe University Specialized Hospital besides obtained tomography kept the irradiation conditions low with the same image quality.
Benzer Tezler
- Çocuk bilgisayarlı tomografi incelemelerinde teknik parametrelerin radyasyon dozu ve görüntü kalitesi üzerindeki etkisi
Effect of technical parameters on radiation dose and image quality in pediatric computed tomography examinations
İSMAİL FINDIKLI
Doktora
Türkçe
2025
Fizik ve Fizik MühendisliğiAnkara ÜniversitesiMedikal Fizik Ana Bilim Dalı
PROF. DR. TURAN OLĞAR
- Bilgisayarlı tomografide yetişkin akciğer ve göğüs fantomu kullanılarak objektif ve klinik görüntü kalitesinin değerlendirilmesi
Evaluation of objective and clinical image quality using adult lung and chest phantom in computed tomography
AHMET ÖZGÜR KASAPGİL
Yüksek Lisans
Türkçe
2025
Radyoloji ve Nükleer TıpAnkara ÜniversitesiMedikal Fizik Ana Bilim Dalı
PROF. DR. TURAN OLĞAR
- Farklı bilgisayarlı tomografi tarayıcılarının görüntü kalitesi performansının radyasyon dozuna bağlı olarak değerlendirilmesi
Evaluation of image quality performance of different computed tomography scanners depending on radiation dose
BERFİN YILDIRIM
Yüksek Lisans
Türkçe
2024
Radyoloji ve Nükleer TıpAnkara ÜniversitesiMedikal Fizik Ana Bilim Dalı
PROF. DR. TURAN OLĞAR
- Bilgisayarlı tomografide iteratif rekonstrüksiyon modellerinin saçılan radyasyon dozu miktarına etkileri
The effects of iterative reconstruction models on secondary radiation in computed tomography
MURAT DÜNDAR
Yüksek Lisans
Türkçe
2024
Radyoloji ve Nükleer TıpEge ÜniversitesiNükleer Bilimler Ana Bilim Dalı
PROF. DR. ELÇİN EKDAL KARALI
- Bilgisayarlı tomografide hasta dozunu azaltmak için kullanılan bizmut koruyucuların hasta dozu ve görüntü kalitesine etkisi
The effect of bismuth shi̇elds used to reduce patient dose in computed tomography on patient dosage and image quality
YUSUF LEVENT ERTOKTAŞ
Yüksek Lisans
Türkçe
2021
Radyoloji ve Nükleer Tıpİstanbul Aydın ÜniversitesiSağlık Fiziği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ FÜSUN ÇETİN