Farklı bilgisayarlı tomografi tarayıcılarının görüntü kalitesi performansının radyasyon dozuna bağlı olarak değerlendirilmesi

Evaluation of image quality performance of different computed tomography scanners depending on radiation dose

  1. Tez No: 937598
  2. Yazar: BERFİN YILDIRIM
  3. Danışmanlar: PROF. DR. TURAN OLĞAR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Bilgisayarlı tomografi, bilgisayarlı tomografi doz indeksi, görüntü kalitesi, iteratif rekonstrüksiyon, kontrast-gürültü oranı, sinyal-gürültü oranı, Computed tomography, computed tomography dose index, image quality, iterative reconstruction, contrast-to-noise ratio, signal-to-noise ratio
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: 228

Özet

Bilgisayarlı Tomografi (BT) medikal görüntülemede kullanılan diğer görüntüleme sistemlerine göre en yüksek kollektif etkin doz katkısına sahiptir. Bu nedenle, son yıllarda BT tarama protokollerinin optimizasyonuna yönelik çeşitli çalışmalar yapılmıştır. Bu tezin amacı, standart BT görüntü kalitesi fantomu kullanılarak farklı rekonstrüksiyon algoritmalarının subjektif ve objektif görüntü kalitesi parametreleri üzerindeki etkilerinin radyasyon dozuna bağlı olarak değerlendirilmesidir. Çalışmada, Catphan® görüntü kalitesi fantomu kullanılarak farklı BT cihazlarında ve hacim bilgisayarlı tomografi doz indekslerinde (Volume Computed Tomography Dose Index, CTDIvol) gürültü, kontrast gürültü oranı (Contrast-to-Noise ratio, CNR), sinyal gürültü oranı (Signal-to-Noise Ratio, SNR), ters görüntü kalitesi indeksi (Inverse Image Quality Figure, IQFinv), modülasyon transfer fonksiyonu (Modulation Transfer Function, MTF) ve gürültü güç spektrumu (Noise Power Spectrum, NPS) ölçümleri gerçekleştirilmiştir. Bu ölçümlerde, hem filtre geriye projeksiyon (Filtered Back Projection, FBP) yöntemi hem de her BT sistemine özgü iteratif kesit elde etme (Iterative Reconstruction, IR) algoritmasının farklı iterasyon seviyeleri kullanılmıştır. Artan CTDIvol değeri ve IR seviyesi ile tüm Catphan görüntülerinde gürültü değerleri azalırken, SNR, CNR ve IQFinv değerlerinin ise arttığı görülmektedir. Frekans uzayında gerçekleştirilen gürültü analizlerinde, gürültü pik değerinin artan doz ve iterasyon seviyesi ile azaldığı görülmüştür. FOM (Figure of Merit) değerleri artan iterasyon seviyesi ile artmış ve maksimum FOM değerinin elde edildiği tüp voltajı ve doz değeri ise kullanılan BT sistemi ve IR algoritmasına bağlı olarak değişmiştir. Çalışmada ayrıca, maksimum FOM değerlerini veren doz aralıkları belirlenmiştir. Bu tez çalışması, 112F015 numaralı ve“Pediatrik BT İncelemelerinde Görüntü Kalitesinin Farklı Yöntemlerle Ölçülmesi, Yöntemler Arasında Korelasyonun Belirlenmesi ve Radyasyon Dozuyla İlişkisinin Araştırılması”başlıklı TÜBİTAK 1001 projesi kapsamında kısmen desteklenmiştir.

Özet (Çeviri)

Computed Tomography (CT) has the highest collective effective dose contribution compared to other imaging systems used in medical imaging. Therefore, various studies have been carried out to optimize CT scanning protocols in recent years. The aim of this thesis is to evaluate the effects of different reconstruction algorithms on subjective and objective image quality parameters, depending on radiation dose, using the standard CT image quality phantom. In the study, noise, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), inverse image quality figure (IQFinv), modulation transfer function (MTF), and noise power spectrum (NPS) measurements were performed on different CT devices and volume computed tomography dose indexes (CTDIvol) using Catphan® image quality phantom. For these measurements, both the filtered back projection (FBP) method and different iteration levels of iterative reconstruction (IR) algorithm specific to each CT system were used. It is seen that with increasing CTDIvol value and IR level, noise values decrease in all Catphan images while SNR, CNR and IQFinv values increase. In the noise analysis performed in the frequency domain, it was observed that the noise peak value decreased with increasing dose and iteration level. FOM Figure of Merit (FOM) values increased with increasing iteration level, and the tube voltage and dose value at which the maximum FOM value was obtained varied depending on the CT system and IR algorithm used. In addition, dose ranges giving maximum FOM values were determined in the study. This thesis study was partially supported within the scope of the TÜBİTAK 1001 project numbered 122F015 and titled“Measurement of image quality with different methods in pediatric computed tomography examinations, determination of correlation between methods and investigation of its relationship with radiation dose”.

Benzer Tezler

  1. Bilgisayarlı tomografi ile görüntüleme yöntemleri

    Medical imaging methods with computerized tomography

    BARIŞ ARSLAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2005

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    DOÇ. DR. SEDEF KENT

  2. X ışınlı bilgisayarlı tomografide filtrelenmiş geri izdüşüm algoritmalarının paralel ve yelpaze demet açılı uygulamaları

    Parallel and fan beam implementations of filtered back projection algorithms in computerized x-ray tomography

    FATİH ENES ÖMEROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    PROF. DR. SEDEF KENT

  3. Classification of COVID-19 from different computed tomography image datasets with machine learning and deep learning methods

    Farklı bilgisayarlı tomografi görüntü veri kümelerinden makine öğrenme ve derin öğrenme yöntemleriyle COVID-19 sınıflandırılması

    FARID FUAD AL-HAJJ SAIF AL-AREQI

    Yüksek Lisans

    İngilizce

    İngilizce

    2022

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolKocaeli Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MEHMET ZEKİ KONYAR

  4. Toraks bilgisayarlı tomografi taraması yapılan hastalarda tiroid gland ve orbitaların maruz kaldığı yüzey dozlarının iki farklı cihazda dozimetrik yöntemlerle belirlenmesi ve karşılaştırılması

    Determination and comparison of thyroid gland and orbital surface doses that exposed to radiation in patients undergoing thorax computed tomography in TWO different devices by dosimetric methods

    SEMRA ARSLAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Fizik ve Fizik MühendisliğiAnkara Yıldırım Beyazıt Üniversitesi

    Radyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HÜSEYİN ÇETİN

  5. Makine öğrenimine dayalı akciğer kanserinin erken tanısında belirsizlik ölçeğinin tespiti

    Detection of the uncertainty scale in the early diagnosis of lung cancer based on machine learning

    SEMA ÜZÜLMEZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Aydın Üniversitesi

    Bilgisayar Mühendisliği Ana Bilim Dalı

    PROF. DR. ZAFER ASLAN