Geri Dön

İmplant destekli hareketli protezlerde kullanılan farklı yüzey özelliklerine sahip locator tutucuların aşınmalarının ve tutuculuk kuvvetlerinin değerlendirilmesi

Evaluation of wear and retention forces of locator attachments with different surface properties used in implant supported overdenture

  1. Tez No: 638519
  2. Yazar: MERVE DEDE
  3. Danışmanlar: PROF. DR. FATMA ÜNALAN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Total Parsiyel Protezler Bilim Dalı
  13. Sayfa Sayısı: 129

Özet

Tam dişsiz hastaların implant destekli tam protezler ile tedavi edilmesiyle protezlerde stabilite ve retansiyon eksikliği, sürekli kemik yıkımı, çiğneme fonksiyonunda bozukluk ve sosyal problemler önlenmiş olur. İmplant destekli tam protezlerde retansiyonun sağlanması için esas olarak locator, top başlı, bar, mıknatıs veya teleskop sistemler kullanılmaktadır. Locator tutucuların kendinden hizalama özelliği nedeniyle hastanın protezlerini minimum aşınmayla rahatlıkla yerine oturtabilmesi, implant ve üst yapı arasındaki açılanmaları 40 dereceye kadar kompanse edebilmesi ve interoklüzal mesafenin az olduğu durumlarda protezdeki kırılmaları önlemeleri nedeniyle tercih edilmektedirler. Dayanak materyali olarak sıklıkla biyouyumluluk ve mekanik özelliklerinden dolayı titanyum nitrid kaplama kullanılmaktadır. Günümüzde zirkonyadan üretilen locator tutucular ile titanyum karbon nitrid kaplı locator tutucular da başarıyla kullanılmaktadır. Çalışmamızın amacı bu üç locator sisteminin düz ve 10o ile 30o açılı olacak şekilde ağız ortamını taklit eden sıvı ortamda takma çıkarma siklusları sonucundaki aşınmalarının kütle kayıpları ve SEM bulguları ile saptanması ve tutuculuk kuvvetinde meydana gelen kayıpların değerlendirilmesidir. Patriksin yerleştirileceği implant analoğu ve matriks için alüminyum bloklardan yararlanıldı. Açılanma değerlerine uygun olarak açılı deney grupları için deney düzeneği değiştirildi. Her gruptan 7 örnek olacak şekilde toplamda altı grup için 42 örnek oluşturuldu. Alüminyum modeller test sistemine (MTS 858 Mini Bionix II, Eden, Prairie, MN ,USA) eksenel olarak bağlandı. Test sırasında örnekler distile su ile nemlendirilerek ağız ortamı taklit edildi. Sonuç olarak 5.000 siklus sonunda tüm ataşman sistemlerinde tutuculuk kaybı, SEM bulgularında deformasyonlar ve kütle kayıpları olduğu gözlendi. İmplant üstü tam protezlerin stabilizasyonu için 5-7 N değerleri baz alındığında, tüm sistemler referans değerlerinde tutuculuk gösterdiler. Açılı tutucuların retansiyon değerleri ortalamaları arasında istatistiksel olarak anlamlı bir fark bulunamadı. Düz tutucuların retansiyon değerleri ortalamalarına bakıldığında ise titanyum karbon nitrid kaplı locatorın tutuculuğu anlamlı düzeyde yüksek bulundu.

Özet (Çeviri)

Treatment of complete edentulous patients with implant-supported complete dentures prevents the lack of stability and retention, permanent bone destruction, chewing dysfunction and social problems. Locator, ball attachment, bar, magnet or telescope systems are mainly used to provide retention in implant supported complete dentures. Locator attachments are preferred because of the self-aligning feature of this type of attachments, the patient can easily fit the prosthesis with minimum wear, compensate the angles between the implant and the superstructure up to 40 degrees and prevent the fractures in the prosthesis when the interocclusal distance is short. Titanium nitride coating is often used as the base material due to its biocompatibility and mechanical properties. Nowadays, locator attachments produced from zirconia and titanium carbon nitride coated locator attachments are also used with success. The aim of this study is to determine the loss of mass and retention force of the three locator systems which are straight, 10o and 30o angled, as a result of insertion-extraction cycles in wet medium similar to the oral environment. Aluminum blocks were used to placed the matrix and implant analog. The test setup for angled test groups was changed according to the degrees. 42 samples were created for a total of six groups with 7 samples from each group. Aluminum models were axially connected to the test system (MTS 858 Mini Bionix II, Eden, Prairie, MN, USA). During the test, the samples were moistened with distilled water to simulate the oral environment. As a result, at the end of 5000 cycles, there was a loss of retention in all attachment systems, deformations in SEM findings and mass losses. Based on the 5-7 N values for the stabilization of the complete dentures on the implant, all systems showed conservative reference values. No statistically significant difference was found between the mean retention values of the angle attachments. The retention values of the 0-degree attachments were found to be significantly higher in the titanium carbon nitride coated locator.

Benzer Tezler

  1. İmplantüstü overdenture protezlerde kullanılan farklı locator ve top başlı ataşman lastiklerinin bazı fiziksel özelliklerinin termal yaşlandırma öncesi ve sonrasında karşılaştırmalı araştırılması

    The research study based on a juxtaposition of the physical characteristics of diverse locators and ball-attachment matrices used in implant overdenture prostheses before and after the thermal aging process

    LAMIA NAJAFOVA

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Diş HekimliğiGazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. TURGUT CİHAN AKÇABOY

  2. İmplant destekli hareketli protezlerde kullanılan 3 farklı hassas tutucunun tutuculuk kuvvetlerinin ve aşınma derecelerinin değerlendirilmesi

    The evaluation of the retentional forces and weardegrees of 3 different precision attachments used forimplant supported removable dentures

    VOLKAN SOYLU

    Doktora

    Türkçe

    Türkçe

    2023

    Diş Hekimliğiİstanbul Medipol Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. HANEFİ KURT

  3. İmplant destekli hareketli protezlerde kullanılan çeşitli bağlantı sistemlerine mekanik ve termal yaşlandırma işlemlerinin etkisinin incelenmesi

    Investigation of the effects of mechanical and thermal aging processes of various connection systems used in implant assisted motivated prostheses

    MUSTAFA YILDIRIM

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Diş HekimliğiRecep Tayyip Erdoğan Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MURAT ALKURT

  4. Implant destekli hareketli protezlerde farklı tedavi seçeneklerinde meydana gelen komplikasyonların incelenmesi

    Investigation of complications occuring in different treatment options in implantsupported removable prosthesis

    EZGİ ERDENOL

    Doktora

    Türkçe

    Türkçe

    2023

    Diş HekimliğiBaşkent Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SELİM ERKUT

  5. Mandibular implant destekli hareketli protezlerde implant sayısı ve tutucu türünün kemikteki stres dağılımlarına etkisinin sonlu elemanlar analizi ile incelenmesi

    The evaluation of the effect of number of implants and type of attachment on the stress distribution in bone: a finite element analysis

    ZEYNEP SELDA ARAT

    Doktora

    Türkçe

    Türkçe

    2010

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ÖMER KUTAY