Farklı kırma kusurlarında sikloplejinin iridokorneal açıya etkisinin pentacam ile değerlendirilmesi
To evaluate the effects of cycloplegic eye drops on pentacam parameters in different refractive errors
- Tez No: 647883
- Danışmanlar: PROF. DR. VUSLAT GÜRLÜ
- Tez Türü: Tıpta Uzmanlık
- Konular: Göz Hastalıkları, Eye Diseases
- Anahtar Kelimeler: Göz içi basıncı, Kırma kusuru, Sikloplejin, Pentacam, Cycloplegic, Pentacam, intraocular pressure, refractive errors
- Yıl: 2020
- Dil: Türkçe
- Üniversite: Trakya Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Göz Hastalıkları Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 75
Özet
Bu çalışmanın amacı farklı kırma kusuru tiplerinde, %1'lik siklopentolat hidroklorür ile sağlanan sikloplejinin, kornea ve ön kamara parametrelerin üzerinde olan etkisini Pentacam ile değerlendirmek ve ortaya çıkan farklılıkların GİB üzerindeki etkilerini retrospektif olarak incelemektir. Çalışmaya Trakya Üniversitesi Tıp Fakültesi Göz Hastalıkları AD Polikliniğine Ocak 2019-Ocak 2020 tarihleri arasında başvuran 157 olgunun 314 gözü alındı. Bunlardan, 114 göz emetrop, 99 göz hipermetrop ve 101 göz miyoptu. Tüm olguların tam oftalmolojik muayeneleri, sikloplejin damla öncesi ve sonrası Pentacam ölçümleri yapıldı ve sonuçlar istatistiksel olarak değerlendirildi. Sikloplejin damla öncesi ve sonrası emetroplarda kornea hacmi (p=0,002), hipermetroplarda kornea hacmi ve distal apeksteki en ince yer (sırasıyla p=0,012 p=0,000), miyoplarda ise kornea merkezi ve kornea hacmi (sırasıyla p=0,004 p=0,001) ortalama değerleri arasında anlamlı fark saptandı. Sikloplejin öncesi ve sonrası değerlendirilen ön kamara hacmi, ön kamara açısı, pupil çapı ve ön kamara derinliği (p=0,000 p=0,000 p=0,000 p=0,000) ortalamaları arasındaki farkın tüm gruplarda istatiksel olarak anlamlı olduğu görüldü. Tüm gözlerin sikloplejin öncesi ve sonrasına ait GİB ortalamaları karşılaştırıldığında; her üç grupta da aralarındaki farkın anlamlı olduğu görüldü (sırasıyla p=0,000 p=0,000, p=0,000). Ön kamara derinlik farkının GİB farkı üzerinde etkisi olduğu tespit edildi (p=0,005). Sonuç olarak, ön kamara parametreleri kırma kusuru bulunan gözlerde emetrop gözlere göre farklılıklar göstermektedir. Sikloplejin sonrası tüm gözlerde ön kamara parametrelerinde değişiklikler ortaya çıkmakla birlikte, GİB üzerine etkisi olduğu tespit edilen tek parametrenin ön kamara derinliğinin değişimi olduğu saptanmıştır.
Özet (Çeviri)
The aim of this study is to investigate the effects of topically applied cycloplegic eye drops on cornea and anterior segment parameters obtained with a Pentacam rotating Scheimpflug camera in different types of refractive errors and to evaluate the effects of results on intraocular pressure (IOP) retrospectively. In the study, 314 eyes of 157 patients who were admitted to Trakya University Medical Faculty Ophthalmology Department between January 2019 and January 2020 were included, 114 emetropia, 99 hypertropia and 101 myopia. After the scanning of the anterior segment of each eye by using Oculus Pentacam, cycloplegic was performed to the each eye.After 45 minutes of cycloplegic application, the second measurements were taken with Pentacam and the values of the cornea, anterior segments parameters and IOP results were compared statistically. The study was conducted on 72 males and 85 females and the mean of the all subjects was 27,76 ± 7,25 (14 -40) years. Before and after cycloplegic drop, in emetropia Corneal volume (p = 0.002), in hypermetropia corneal volume and distal apex of thinnest locate(p=0.012 p=0.000, respectively), in myopia corneal center and corneal volume (p=0.004 p=0.001, respectively) measurements between the two sessions were statistically significantly different, the difference between the averages of anterior chamber volume, anterior chamber angle, pupil diameter, and anterior chamber depth(p=0,000 p=0,000 p=0,000 p=0,000) evaluated were statistically significant in all groups. Comparing IOP averages of all eyes before and after cycloplegic; The difference was significant in all three groups (p = 0,000 p = 0,000, p = 0,000, respectively). Anterior chamber depth difference was found to have an effect on the IOP difference (p = 0.005). In conclusion, anterior chamber parameters differ in eyes with refractive errors compared to emetropic eyes. In addition to changes occur in the anterior chamber parameters in all eyes after cycloplegic eye drop, the only parameter found to have an effect on IOP was the change in anterior chamber depth.
Benzer Tezler
- Pediatrik popülasyonda farklı refraksiyon kusurlarının, anizometropi ve ambliyopinin optik kohorens tomografi anjiyografi parametreleri üzerine olan etkilerinin değerlendirilmesi ve karşılaştırılması
Evaluation and comparison of the effects of different refractive errors, anisometropia and amblyopia on optical cohorence tomography angiography parameters
MUSTAFA KARADAŞ
Tıpta Uzmanlık
Türkçe
2020
Göz HastalıklarıBaşkent ÜniversitesiGöz Hastalıkları Ana Bilim Dalı
DOÇ. DR. SEZİN AKÇA BAYAR
- Akdeniz kıyı yengecinin (Carcinus aestuarii) midye (Mytilus galloprovincialis) populasyonu üzerine etkileri
Impacts of Mediterranean shore crab (Carcinus aestuarii) on black mussel (Mytilus galloprovincialis) population
MEHMET GÜLER
Yüksek Lisans
Türkçe
2007
Su ÜrünleriEge ÜniversitesiSu Ürünleri Yetiştiriciliği Ana Bilim Dalı
PROF. DR. AYNUR LÖK
- Filiz kırmanın bazı patates çeşitlerinde (S.tuberosum l.) verim ve kaliteye etkisi
Başlık çevirisi yok
EMEL SARGIN
- Çeti [Prosopis farcta (Banks & Sol.) Mac.]' nin çimlenme biyolojisi ve kimyasal mücadelesi üzerine araştırmalar
Investigation on germination biology and chemical control of mesquite [Prosopis farcta (Banks & Sol.) Mac.]
GÜNCE AKKUZU
- Farklı kepek fraksiyonlarından hazırlanan un paçallarının değişik depolama koşullarında hamur ve ekmek özelliklerine etkisi
The effect of flour blends prepared with different bran fractions on dough and bread properties at varied storage conditions
ÖZEN AKBAŞ
Yüksek Lisans
Türkçe
2010
Gıda MühendisliğiSelçuk ÜniversitesiGıda Mühendisliği Ana Bilim Dalı
DOÇ. DR. NERMİN BİLGİÇLİ