Mandibular ilerletmede kullanılan farklı sabit fonksiyonel apareylerin dentoalvelolar yapılar üzerindeki etkilerinin sonlu elemanlar analiz yöntemi ile değerlendirilmesi

Evaluation of the effects of different fixed functional appliances used in mandibular advancement on dentoalveolar structures using finite element analysis method

  1. Tez No: 660511
  2. Yazar: MUSTAFA ONUR ŞENGEZER
  3. Danışmanlar: DR. ÖĞR. ÜYESİ EYÜP BURAK KÜÇÜK
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Forsus, PowerScope, Herbst, Sonlu elemanlar analizi, Fonksiyonel tedavi
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: Hatay Mustafa Kemal Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 150

Özet

Giriş ve Amaç: Bu çalışmanın amacı, yakın dönemde üretilmiş olan ve klinik uygulaması kolay olan PowerScopeR2 (2014 American Orthodontics Corporation, Sheboygan, Wisconsin) apareyinin mandibula, maksilla ve dentoalveolar yapılar üzerindeki etkilerinin in vitro olarak sonlu elemanlar analizi ile değerlendirilmesi ve klinik rutininde çok kullanılan ForsusTM Fatigue Resistant Device EZ2 (FRD; 3M Unitek, Monrovia, California) ve Herbst (Dentaurum Inc., Newtown) apareyleri ile etkileri arasındaki farkların incelenmesi ve karşılaştırılmasıdır. Gereç ve Yöntem: Çene kemiklerininin üç boyutlu sonlu elemanlar modeli, büyüme gelişimi tamamlanmış bir bireyden konik ışınlı tomografi ile elde edilmiş ve çalışmanın yapıldığı firmadan temin edilmiştir (Ay tasarım, Ankara). Forsus, PowerScope2 ve Herbst apareyleri, üç ayrı sonlu elemanlar modelinde uygulanıp dişler, dentoalveolar yapılar ve çene kemikleri üzerindeki von Mises gerilme, minimum-maksimum asal gerilme ve yer değiştirme değerleri sonlu elemanlar analiz yöntemi ile değerlendirilmiştir. Bulgular: PowerScope2 apareyi uygulanan modelde alt kesici dişlerde, Forsus ve Herbst apareyi uygulanan modellerden daha fazla protrüzyon gözlenmiştir. Herbst apareyinin uygulandığı modellerde dişlerde von Mises gerilme değerleri diğer iki apareye göre oldukça yüksek gözlenmiştir. Sabit fonksiyonel apareylerin üst çene molar dişlerinde meydana getirdiği distalizasyon miktarı en fazla Herbst apareyinin uygulandığı modelde gözlenmiştir. Sonuç: Çalışmamızda yüksek von Mises gerilimleri tüm simülasyonlarda kuvvetin iletildiği dişlerde görülmüştür. Yakın dönemde üretilmiş olan ve uygulama açısından diğer iki apareye göre daha kolay olan PowerScope2 apareyinin de diğer iki apareyle benzer etkiler oluşturduğu üst çenede istenmeyen molar dişte bukkal tiping gibi etkilerin ve mandibular retrognatili hastalarda istenmeyen üst çene molar distalizasyonun önlenmesi amacıyla ek önlemler alınması gerektiği tespit edilmiştir.

Özet (Çeviri)

Introduction and Aim: The aim of this study is to evaluate the effects of the PowerScopeR2 (2014 American Orthodontics Corporation, Sheboygan, Wisconsin) appliance, which is newly produced and of which clinical application is easier than many other fixed functional apparatus, on the structures of mandible, maxilla and dentoalveolar using finite analysis method in vitro and to study and compare the differences of its effects from ForsusTM Fatigue Resistant Device EZ2 appliance (FRD; 3M Unitek, Monrovia, California ) and Herbst (Dentaurum Inc., Newtown) appliance which are widely used in routine clinic practices. Material and methods: The three-dimensional finite element model of the jaw bones was obtained via cone beam tomography of an individual whose growth development was completed and it was provided by the firm where the study was conducted (Ay Tasarım, Ankara). Forsus, PowerScope2 and Herbst appliances were used in three separate finite element models and the values of von Mises stress, minimum-maximum principal stress and displacement on teeth, dentoalveolar structures and jaw bones were evaluated via finite element analysis method. Results: More protrusions were observed in the lower incisors of the model applied with PowerScope2 appliance when compared with the models applied with Forsus and Herbst appliances. Von Mises stress values were observed to be quite high in the models where Herbst appliances were applied when compared to the other two appliances. The amount of distalization in the upper jaw molar teeth caused by fixed functional appliances was observed to be the highest in the model where the Herbst apparatus was applied. Conclusion: In our study, it is observed that the high von Mises stresses were seen in the teeth where the force was transmitted in all simulations. It has been found out that PowerScope2 appliance, which is newly produced and can be applied easier when compared with the other two appliances, creates similar effects as the other two and that additional precautions should be taken to prevent undesirable buccal tiping effects in upper jaw and unwanted maxillary molar distalization in retrognatic patients. Keywords : Forsus, PowerScope, Herbst, Finite element analysis, Functional therapy

Benzer Tezler

  1. Mandibulanın ileri ilerletme ve beraberindeki rotasyon hareketinde kullanılan farklı fiksasyon yöntemlerinin karşılaştırılması

    Comparison of different fixation methods used in advancedadvancement and counterclockwise rotation of mandible

    NİDA GEÇKİL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiÇukurova Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    DOÇ. HÜSEYİN CAN TÜKEL

  2. Sonlu elemanlar analizi ile maksillomandibular kompleksi modelinde saat yönü tersine rotasyon ve ilerletmede farklı fiksasyon tiplerinin karşılaştırılması

    Başlık çevirisi yok

    SERHAT CAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiMarmara Üniversitesi

    Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı

    PROF. DR. ALTAN VAROL

  3. Sagittal split ramus osteotomisinde farklı kortikal kemik kalınlıklarında farklı çap ve boydaki vidaların fiksasyon etkisinin sonlu eleman analizi ile incelenmesi

    Stability of sagittal split osteotomy fixation system using different screw dimensions in correlation to cortical bone thickness a finite element study

    MUHAMMED HUMAM TELLOOĞLU

    Doktora

    Türkçe

    Türkçe

    2020

    Diş Hekimliğiİstanbul Medipol Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    Prof. Dr. SİNA UÇKAN

  4. Mandibular ilerletme ve saat yönünün tersine rotasyon cerrahisinde inferior alveolar sinir üzerinde oluşan stres dağılımının üç boyutlu sonlu elemanlar analizi ile değerlendirilmesi

    Evaluation of the stress distribution on the inferior alveolar nerve in mandibular advancement and counterclockwise rotation surgery with THREE-dimensional finite element analysis

    ŞEBNEM DUYGULU

    Diş Hekimliği Uzmanlık

    İngilizce

    İngilizce

    2023

    Diş HekimliğiNecmettin Erbakan Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. DR. ALPARSLAN ESEN

  5. Mandibulanın cerrahi olarak saatin tersi yönünde rotasyonundan sonra posterior açılı kondil üzerinde oluşan streslerin değerlendirilmesi

    Stress distrubition of posteriorly inclined condyles after surgically induced counter-clockwise rotation of the mandible

    SEVİM ÇAKILTAŞ

    Doktora

    Türkçe

    Türkçe

    2019

    Diş HekimliğiBezm-i Alem Vakıf Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. DR. NÜKHET KÜTÜK