In vitro comparison of the microbial leakage in two different implant-abutment systems
İki farklı implant-dayanak sisteminin mikrobiyal sızıntısının in vitro olarak değerlendirilmesi
- Tez No: 697789
- Danışmanlar: PROF. DR. YASEMİN ÖZKAN
- Tez Türü: Yüksek Lisans
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Mikrobiyal sızıntı, implant, konometrik konsept, dinamik yükleme, Dental implantasyon, Dental implantlar, Dental sızma, Protezler ve implantlar, Takma diş tabanları, İn vitro, Microbial leakage, dental implants, conometric concept, dynamic loading, Dental implantation, Dental leakage, Prostheses and implants, Denture bases, In vitro
- Yıl: 2021
- Dil: İngilizce
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: İmplant-dayank arayüzündeki mikro boşluk, kaçınılmaz olmasına rağmen, uygun dayanak seçilerek en aza indirilebilir. Çalışmanın amacı, statik durumda ve dinamik yükleme sonrasında iki implant-dayanak sisteminin mikrobiyal sızıntısını araştırmak ve karşılaştırmaktır. Gereç ve yöntem: Çalışmada AstraTech Osseospeed implant ve iki farklı abutment kullanıldı; acuris konometrik abutment ve ti-base abutment (Dentsply Implants, İsveç). lityum disilikat (IPS e.max CAD, Ivoclar Vivadent, Lihtenştayn) kronlar ile restore edildi. İmplantın iç kısmına bakteri süspansiyonu ile aşılandı. Numuneler statik testi icin, 7 gün triptik soya suyuna yerleştirildi. Dinamik yükleme altında için çiğneme simülatörüne yüklendi ve her iki durumda bakteri örnekleri alındı. Bulgular: Bu incelemede her iki grupta da mikrosızıntı olmasına rağmen farklı seviyelerdeydi. Statik koşullar altında ti-base abutment herhangi bir sızıntı göstermedi (0,0 ± 0,0), ancak Acuris konometrik abutment 6 örnekten 3'ü minimum sızıntı gösterdi (500,0 ± 547,7). her iki sistem de yükleme sonrası sızıntı bulguları üretti, Grup A (388333,3 ± 487048,9) ve Grup B (20000,0 ± 15491,9). Her iki durumda gruplar arasında ve gruplar içi anlamlı fark yoktu (p>0.50). Sonuç: bu in vitro çalışmanın sınırlaması dahilinde, her iki sistemin de yüklemeden önce ve sonra benzer bakteri sızıntısı gösterdiği sonucuna varılabilir.
Özet (Çeviri)
Objective: The microgap in the implant-abutment interface although unavoidable can be minimized by choosing the suitable abutment. The aim of this study is to compare the microbial leakage of two implant-abutment systems before and after loading. Materials and Methods: AstraTech Osseospeed EV implant and two different abutments were used; prefabricated ti-base abutment (Group A) and Acuris conometric abutment (Group B) (Dentsply Implants, Sweden). Lithium disilicate (IPS.e.max CAD, Ivoclar Vivadent, Liechtenstein) crowns were fabricated. Bacterial suspension was inculcated into the implant. The samples were immersed in tryptic soy broth for static condition, and then been loaded into a chewing simulator. Bacterial samples were obtained and cultivated after both static and dynamic loading. Results: Although there was microleakage in both groups in this investigation it was at different levels. Under static conditions ti-base abutment did not show any leakage (0,0 ± 0,0) however 3 out of 6 Acuris conometric abutment showed minimal leakage (500,0 ± 547,7). Both systems produced leakage findings in 4 out of 6 after loading for Group A (388333,3 ± 487048,9) and Group B (20000,0 ± 15491,9). There was no significant difference between and within the groups in both conditions (p>0.50). Conclusion: within the limitation of this in-vitro study it can be concluded that both systems showed similar bacterial leakage before and after loading.
Benzer Tezler
- Farklı implant sistemlerinde implant-destek parça birleşim yüzeyleri arası mikroorganizma sızıntısı ve çevre dokulara olası etkilerinin incelenmesi
Comparison of microbial leakage through various implant-abutment connection mechanisms and its possible effect on surrounding tissues
ALİ MÜFTÜ
- Ovulasyon indüksiyonu tedavisinde folliküler gelişimin ultrasonografik takibi
Başlık çevirisi yok
MERİH BAYRAM
Tıpta Uzmanlık
Türkçe
1987
Kadın Hastalıkları ve DoğumGazi ÜniversitesiKadın Hastalıkları ve Doğum Ana Bilim Dalı
DOÇ. DR. MÜLAZIM YILDIRIM
- Çimentonun sertleşmesi üzerinde kimyasal komponentlerin etkisi
Başlık çevirisi yok
NACİYE TÜRKEL
Yüksek Lisans
Türkçe
1986
Kimya MühendisliğiUludağ ÜniversitesiKimya Ana Bilim Dalı
PROF. DR. MUSTAFA CEBE
- Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi
Kinetic study and detesmination of thermodnamic parameters of some esters
İBRAHİM TAŞ
Yüksek Lisans
Türkçe
1986
Kimya MühendisliğiUludağ ÜniversitesiKimya Ana Bilim Dalı
PROF. DR. MUSTAFA CEBE
- İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar
Başlık çevirisi yok
BAHAR TÜRKYILMAZ
Yüksek Lisans
Türkçe
1985
Şehircilik ve Bölge PlanlamaEge ÜniversitesiŞehir ve Bölge Planlama Ana Bilim Dalı