Rotasyon hareketi yapan farklı koniklik açısına sahip nikel titanyum eğe sistemlerinin apikalden taşan debris miktarlarının karşılaştırılması
Comparison of nickel titanium file systems with different angle of taper with rotational motion on amount of apical extrusion of debris
- Tez No: 709897
- Danışmanlar: DR. ÖĞR. ÜYESİ FARUK ÖZTEKİN
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Debridman, Dental eğeler, Dental pulpa boşluğu, Endodonti, Kök kanal tedavisi, Nikel-titanyum alaşımları, Debridement, Dental files, Dental pulp cavity, Endodontics, Root canal therapy, Nickel-titanium alloys
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Fırat Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Endodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu tez çalışmasının amacı rotasyon hareketi yapan farklı koniklik açısına sahip nikel titanyum eğe sistemlerinin apikalden taşan debris miktarlarının karşılaştırılmasıdır Apeks tam olarak oluşturulmuş, kırıksız, daha önce endodontik tedavi görmemiş ve bir kök kanalına sahip altmış mandibular premolar seçildi. Sadece Vertucci tip I sınıflandırmasına sahip premolarlar seçildi. Seçilen dişler yirmişerli olacak şekilde üç gruba ayrıldı. Bu gruplar 3 farklı tapera sahip eğelerle kanal preparasyonu tamamlandı. Her diş kendi grubundaki Ni-Ti döner alet eğeleriyle prepare edildi. Preparasyonda kullanılan eğeler her seferinde kök kanalından çıkarıldı ve steril gazlı bez ile temizlendi. Her eğe kullanımından sonra dişler %2,5 NaOCl ile irrige edildi ve apikal foramende 15 numara K-file kullanılarak açıklık kontrol edildi. Ekstrüde döküntüleri toplamak için bu çalışmada daha önce açıklanan bir aparat benimsenmiştir (82).Her numune, numunenin apikal 5 mm'lik bölümü tüpün içinde ve koronal kısmı dışarıda olacak şekilde önceden özel olarak yapılmış bir delikten bir Eppendorf tüpünün kapağına sabitlendi. Numune ile Eppendorf tüpü arasındaki boşluk Top Dam (FGM, Joinville, SC, Brezilya) ile kapatıldı. Daha sonra, Eppendorf tüpü ters çevrildi ve alt kısım kesildi, apikal kök tamamen aplanana kadar %1,5 agaroz jelin döküldüğü bir açıklık oluşturuldu. Aparat jel katılaşana kadar aynı pozisyonda kaldı. Agaroz jeli, debris toplamak için bir matris sağladı (82). Taşan dentin talaşı artıklarının ağırlığı, başlangıç ağırlığının (boş tüp ağırlıkları) son ağırlıktan çıkarılmasıyla belirlenmiştir. . Eğe sisteminin değişen tapera göre taşan debris miktarında farklılık bulunup bulunmadığını tespit etmek üzere One way Anova testinden yararlanılmıştır. Grupların ikili kıyaslaması için Post Hoc testi olarak Bonferroni testinden yararlanılmıştır. Tüm aletler apikal debris ekstrüzyonu ile ilişkilendirilmiştir. Elde edilen sonuçlara göre gruplar arasında taşan debris miktarları bakımından istatistiksel olarak anlamlı bir farklılık bulunmaktadır (F=469,279, p<0,05). Taşan debris miktarı ağırlığının en yüksek 0.6 Taper eğede (0,031±0,003), en düşük ise 0.2 Taper eğede (0,008±0,002) olduğu belirlenmiştir.
Özet (Çeviri)
The aim of this thesis study is to compare the amount of apically extruded debris from nickel titanium file systems with different taper angles that rotate. Sixty mandibular premolars with a fully formed apex, no fractures, no previous endodontic treatment, and one root canal were selected. Only premolars with Vertucci type I classification were selected. The selected teeth were divided into three groups as twenty each. In these groups, canal preparation was completed with files with 3 different tapers. Each tooth was prepared with Ni-Ti rotary instrument files in its own group. The files used in the preparation were removed from the root canal each time and cleaned with sterile sponge. After each file use, the teeth were irrigated with 2.5% NaOCl and patency was checked using a #15 K-file in the apical foramen. An apparatus previously described in this study was adopted to collect the extruded debris (82). It was fixed to the cap of an Eppendorf tube through a pre-made hole with the apical 5 mm part inside the tube and the coronal part out. The opennes between the sample and the Eppendorf tube was sealed with Top Dam (FGM, Joinville, SC, Brazil). Next, the Eppendorf tube was inverted and the bottom cut off, creating an opening into which 1.5% agarose gel was poured until the apical root was completely approximated. The apparatus remained in the same position until the gel solidified. The agarose gel provided a matrix to collect debris (82). The weight of the overflowing dentin shavings was determined by subtracting the initial weight (empty tube weights) from the final weight. . One way Anova test was used to determine whether there was a difference in the amount of extruded debris according to the changed tapering of the file system. Bonferroni test was used as Post Hoc test for pairwise comparison of the groups. All instruments were associated with apical debris extrusion. According to the results obtained, there was a statistically significant difference between the groups in terms of the amount of extruded debris (F=469.279, p<0.05). It was determined that the weight of extruded debris was highest in 0.6 Taper file (0.031±0.003) and lowest in 0.2 Taper file (0.008±0.002).
Benzer Tezler
- Rotasyon hareketi yapan üç farklı nikel-titanyum eğe sisteminin yapay kanalda döngüsel yorulma dirençlerinin karşılaştırılması
Comparison of cyclic fatigue resistance of three different nickel-titanium rotary file systems in artificial canal
BERİVAN BİNGÖL KAYA
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiDicle ÜniversitesiEndodonti Ana Bilim Dalı
PROF. DR. ÖZKAN ADIGÜZEL
- Ritmik cimnastikte iki farklı hızda yapılan chainé rotasyon sonrası yan denge hareketinin biyomekanik analizi
Biomechanics analysis of the side balance activity after chainé rotation under the two varying speeds in the rytmic gymnastics
FİGEN ALTAY
Doktora
Türkçe
2001
SporHacettepe ÜniversitesiEgzersiz ve Spor Fizyolojisi Ana Bilim Dalı
Y.DOÇ.DR. ZİYA KORUÇ
- Tam tur dönen ve resiprokasyon hareketi ile çalışan nikel titanyum döner eğelerin döngüsel yorgunluğuna kullanıcı tecrübesinin etkisinin araştırılması
Comparison of the effect of operator experience on cyclic fatigue resistance of reciprocating and rotating nickel-titanium rotary file systems
HANDE ÖZYÜREK
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiKocaeli ÜniversitesiPedodonti Ana Bilim Dalı
DOÇ. DR. MESUT ELBAY
- Şeffaf plak tekniğinde kullanılan farklı kompozit ataşmanların ve üçüncü molar varlığının maksiller molar distalizasyonuna etkisinin sonlu elemanlar metodu ile incelenmesi
Investigation of the effect of different composite attachments used and the presence of the third molar on maxillary molar distalization in the clear aligner technique using the finite element method
ASLIHAN KUĞUOĞLU
Diş Hekimliği Uzmanlık
Türkçe
2023
Diş HekimliğiHacettepe ÜniversitesiOrtodonti Ana Bilim Dalı
DOÇ. DR. BENGİSU AKARSU GÜVEN
- Comparison of muscle oxygenation and total hemoglobin levels during isokinetic concentric and eccentric contraction at different speeds in athletes
Sporcularda farklı hızlarda izokinetik konsantrik ve eksentrik kasılma anında kas oksijenasyon ve toplam hemoglobin düzeylerinin karşılaştırılması
DUR SAMAND
Yüksek Lisans
İngilizce
2024
Fizyoterapi ve RehabilitasyonGazi ÜniversitesiFizyoterapi ve Rehabilitasyon Ana Bilim Dalı
PROF. DR. NEVİN AYSEL GÜZEL