Geri Dön

Strain measurements on Fe, Niand NiFe embedded carbon fiberepoxy composite

Başlık çevirisi mevcut değil.

  1. Tez No: 717481
  2. Yazar: ILGIM GÜDEN
  3. Danışmanlar: PROF. NİCOLA MORLEY
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kimya Mühendisliği, Chemical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2020
  8. Dil: İngilizce
  9. Üniversite: The Unıversıty Of Sheffıeld
  10. Enstitü: Yurtdışı Enstitü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Özet yok.

Özet (Çeviri)

The magnetisations of a woven carbon/epoxy composite embedded with ~1 volume percent of Fe, Ni and NiFe powder particles (6-200 µm) were measured at the tensile strains from 0.833 to 1.6 mstrain. The powder embedded composite test plates (1x25x50 mm) were strained using a bending ring test apparatus with various bend radius. The magnetisation of loaded composite samples was measured before and during loading using a 3D Anisotropic Magneto-Resistance sensor in three directions. The maximum change of magnetisation was measured in the z-axis, normal to the loading direction, and there was almost no change of magnetisation in x and yaxis. The total change of magnetisation was found to be parallel with the change of magnetisation in the z-axis. The composites embedded with the particles less than 80 µm showed an increasing change of magnetisation with increasing bending strain. The determined piezo-magnetic stress and strain coefficients of the composites embedded with less than 80 µm particles were shown to be similar with those of similar composites tagged with Terfenol-D particles. The results also showed that magnetic Fe and Ni particle addition to composites can be used to measure strain within the composites remotely for structural health monitoring. The errors in magnetisation measurements including the sensor-sample distance and the stress state (reduction of the tensile stress in the thickness direction) are discussed. In order to prevent the stress state effect, powder addition to only the upper and lower surfaces of the composite plate is recommended. The studied powder added composite should be further investigated for optimum powder size in order to increase the accuracy of magnetisation measurements.

Benzer Tezler

  1. Gazi tipi eksternal fiksatörlerle yapılan uygulamalarda kırık hattındaki kompresyonun biyomekanik olarak“strain gage”lerle tayini

    Başlık çevirisi yok

    HÜSEYİN ŞENGÜL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...

  2. Purification of bacteriorhodopsin from halobacterium halobium and reconstitution studies in liposomes

    Başlık çevirisi yok

    M.BAKER ZABUT

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Orta Doğu Teknik Üniversitesi

    Biyokimya Ana Bilim Dalı

    Yükleniyor...

  3. Bira ve alkol üretiminde kullanılan bazı enzimlerin mikrobiyal yolla eldesi

    Başlık çevirisi yok

    HÜSEYİN ÜSTÜNES

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Boğazdan izole edilen coliform bakterilerin B- laktamaz enzim aktivitelerinin tesbit edilmesi ve B-laktamaz pozitif coliformların penisilinetkisinin inaktivasyonunun in vitro deneylerle gösterilmesi

    The Detection of beta-lactamasa activity of coliform bacteria isolated from th roat cultures and slovving the inactivation of penicilin by this beta lactamase produced by this caliform organisms

    GÜVEN URAZ

    Doktora

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Genel Biyoloji Ana Bilim Dalı

    Yükleniyor...