Geri Dön

Hiperparatiroidide Tc99m-sestamibi çift faz planar sintigrafik görüntüleme ile SPECT / BT görüntülemenin karşılaştırılması

Comparison of planar imaging with dual phase Tc99m sestamibi parathyroid sintigraphy and SPECT/CT imaging for hyperparatiroidism

  1. Tez No: 725399
  2. Yazar: HALİM ÖZÇEVİK
  3. Danışmanlar: UZMAN MEHMET MÜLAZIMOĞLU
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Hiperparatiroidi, SPECT/BT, Teknesyum-99m-Sestamibi, Hyperparathyroidism, SPECT/CT, Technetium-99m-Sestamibi
  7. Yıl: 2012
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bakanlığı
  10. Enstitü: İstanbul Okmeydanı Eğitim. ve Araştırma. Hastanesi
  11. Ana Bilim Dalı: Nükleer Tıp Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 86

Özet

Amaç: Tc99m-sestamibi ile paratiroid sintigrafik görüntülemenin çeşitli yöntemleri bulunmaktadır. Bu yöntemleri direkt karşılaştıran sınırlı sayıda çalışma bulunmaktadır. Bu çalışmada da amaç Tc99m-sestamibi çift faz planar görüntüleme yöntemi ile geç SPECT/BT görüntülemenin karşılaştırılmasıdır. Gereç ve Yöntem: Hiperparatiroidi ön tanısı alan, paratiroid cerrahisi uygulanarak patolojik incelemesi yapılan 36 olgu çalışmaya dahil edildi. Nükleer tıp kliniğinde 20. ve 120. dakikada çift faz Tc99m-sestamibi planar sintigrafisi ve 120. dakikadaki planar görüntülemenin hemen ardından SPECT/BT görüntülemesi yapılan 36 olgunun görüntüleri iki nükleer tıp uzmanı tarafından lezyon bazında vizüel olarak değerlendirildi. Çift faz planar ve SPECT/BT görüntüler duyarlılık, özgünlük, pozitif öngörü değeri, negatif öngörü değeri ve doğruluk açısından istatistiksel olarak karşılaştırıldı. Bulgular: 36 hastada cerrahi sonrası bulunan 41 lezyon değerlendirildiğinde çift faz planar görüntüleme ile geç faz SPECT/BT nin karşılaştırılmasında sırayla duyarlılığı %84,21-%94,74, Özgünlüğü %66,67-%66,67 Pozitif öngörü değeri %96,97-%97,30 negatif öngörü değeri %25-%50,0 doğruluk %82,93-%92,68 olarak bulunmuştur. Planar görüntüleme ile SPECT/BT arasında incelemede istatistiksel olarak anlamlı farklılık görülmektedir. SPECT/BT patolojiye daha yakın sonuç vermektedir. Yanılma payı daha düşük, doğruluk oranı daha yüksek olarak saptanmıştır. Sonuç: SPECT/BT, hiperparatiroidi nedeniyle görüntüleme yapılacak olan hastalarda planar görüntülemeye göre hem doğruluk hem lokalizasyon avantajı dolayısı ile tercih edilmesi gereken bir görüntüleme yöntemidir.

Özet (Çeviri)

Aim: There are various methodologies for Tc99m-sestamibi parathyroid sintigraphy. There are few direct comparisons between different methods. The purpose of this study is to compare the dual phase Tc99m-sestamibi parathyroid sintigraphy with SPECT/CT imaging. Material and Method: 36 patients with a diagnosis of hyperparatiroidism that had undergone parathyroid surgery and had been examined histopathologically were included in this study. Dual phase Tc99m-sestamibi parathyroid sintigraphy was performed at 20min and 120 min after injection and immediately after planar imaging that had been acquired at 120 min, SPECT/CT imaging were performed on 36 patients. Images were interpreted by two experienced nuclear medicine physicians visually on the basis of lesions. Dual phase parathyroid scintigraphy and SPECT/CT images were compared statistically in regards to sensitivity, specificity, positive predictive value, negative predictive value and accuracy. Result: Surgically confirmed 41 lesions in 36 patients were evaluated. As the planar imaging was compared with delayed phase SPECT/CT, sensitivity were %84.21 and %94.74, specificity were %66.67 and %66.67, positive predictive value were %96.97 and %97.30, negative predictive value %25 and%50 and accuracy were%82.93 and %92.68 relatively. Comparison of planar imaging with SPECT/CT showed statistically significant difference. Results of SPECT/CT were closed to that of pathology. Fallibility was lower and accuracy was higher than that of planar imaging. Conclusion: Because the SPECT/CT imaging has the advantage of accuracy and localization over planar imaging, it is the imaging modality that should be preferred on patients with a diagnosis of hyperparathyroidism.

Benzer Tezler

  1. Minimal invazif paratiroidektomilerde ameliyat öncesi lokalizasyon tayininde teknesiyum-99M sestamibi sintigrafisi ile ultrasonografinin karşılaştırmalı rolü

    Comparative role of technetium – 99M sestamibi scintigraphy and ultrasound on detection of preoperative localization in minimally invasive parathyroidectomy

    ELSHAD RZAYEV

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2016

    Genel Cerrahiİstanbul Üniversitesi

    Genel Cerrahi Ana Bilim Dalı

    DOÇ. DR. MEHMET SİNAN ÇARKMAN

  2. Normal ve ektopik yerleşimli paratiroid adenomlarının SPECT ve planar görüntülerinin retrospektif olarak incelenmesi

    Retrospective evaluation of SPECT and planar images of normal and ectopic localized parathyroid adenomas

    ÜLKÜ KORKMAZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2011

    Endokrinoloji ve Metabolizma HastalıklarıTrakya Üniversitesi

    Nükleer Tıp Ana Bilim Dalı

    PROF. DR. ALİ SARIKAYA

  3. Primer hiperparatiroidi hastalarında intraopereratif parathormon ölçümünün etkinliği

    Effectiveness of intraopererative parathyroi̇d hormone measurement in primary hyperparatyroidsm patients

    ERDEM SARI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Genel Cerrahiİzmir Katip Çelebi Üniversitesi

    Genel Cerrahi Ana Bilim Dalı

    PROF. DR. MEHMET HACIYANLI

  4. 1988-2001 yılları arasında primer hiperparatiroidi vakalarının klinik ve laboratuar bulgularının retrospektif incelemesi

    Clinical and laboratory findings of patients with primary hyperparathyroidism between years of 1988-2001

    TANSU TANRIVER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2002

    Endokrinoloji ve Metabolizma Hastalıklarıİstanbul Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    PROF.DR. HÜSREV HATEMİ