Farklı implant tasarımlarının farklı dansitedeki kemiklerde meydana getirdiği stresin sonlu elemanlar analizi yöntemi ile değerlendirilmesi

Evaluation of the stress of different implant designs in different bone densities using finite element analysis

  1. Tez No: 729855
  2. Yazar: YASEMİN MERT
  3. Danışmanlar: PROF. DR. ERCAN DURMUŞ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Sonlu eleman analizi, konik implant, silindirik implant, kemik yoğunluğu, Cylindrical implant, conical implant, bone density, Finite element analysis
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 103

Özet

Amaç Çalışmada diş eksikliklerinin tedavisinde kullanılan farklı geometrik yapıya sahip implant materyallerinin ve kemiklerde oluşturdukları streslerin sonlu elemanlar analizi tekniği ile kıyaslanması planlanmaktadır.Yapılacak çalışma ile amaçlanan kemiklerde meydana gelen asal stres dağılımlarını sonlu elemanlar analizi ile karşılaştırmaktır. Gereç ve Yöntemler Çalışmamızda iki farklı yoğunlukta kemik yapısı (D1 ve D4) ; silindirik ve konik dizaynlı implantlar bilgisayar ortamında modellenerek 4 model oluşturulmuştur. Elde edilen kemik modelleri üzerinde silindirik ve konik implantlar ve abutmentlar yerleştirildikten sonra abutment üzerinden 200 N luk vertikal, bukkolingual olarak oblik 30° 100 N ve abutmentın bukkal yüzeyinden 100 N yatay yönde kuvvet uygulanarak oluşan stresler sonlu elemanlar analizi tekniği ile incelenmiştir. Bulgular Vertikal kuvvet sonucunda her iki kemik modelinde implantların boyun bölgesi etrafındaki kortikal kemikte basma stresleri yoğunlaşmış olup homojen bir dağılım göstermiştir. Oblik ve horizontal kuvvetler altında her iki implant dizaynında, implantların etrafındaki kortikal kemikte stresler yoğun olarak görülmüştür. En fazla çekme stresi (Pmax) bütün modellerde mesial ve distal kortikal kemikte daha fazla görülürken, en fazla basma stresi (Pmin) ise bukkal ve lingual kortikal kemiklerde tespit edilmiştir. Sonuç Konik gövde dizaynına sahip implantlar silindirik implantlara oranla kemikte stres dağılımı açısından daha iyi sonuç vermiştir. Yaptığımız çalışmada D1 kortikal kemik kalınlığı en fazla olan D1 kemik gelen stresleri daha iyi karşılayıp homojen dağılım sağlamıştır. Kortikal kemik kalınlığı en az olan ve en yumuşak kemik olan D4 kemik ise gelen kuvvetleri iyi bir şekilde karşılayamamış ve bundan dolayı homojen bir şekilde dağıtamamıştır. Tüm bunlarla birlikte sonuçlar tüm gruplar için fizyolojik sınırlar içerisindedir.

Özet (Çeviri)

Background In the study, it is planned to compare the implant materials with different geometric structures used in the treatment of tooth deficiencies and the stress they create in the bones with the finite element analysis technique. The aim of the study is to compare the principal stress distributions in the bones with finite element analysis. Methods In our study, two different densities of bone structure (D1 and D4); cylindrical and conical designed implants were modeled in computer environment and 4 models were created. After placing cylindrical and conical implants and abutments on the obtained bone models, the stresses created by applying 200 N vertical force over the abutment, 30° 100 N buccolingual oblique force and 100 N horizontal force from the buccal surface of the abutment were investigated by finite element analysis technique. Results As a result of the vertical force, the compression stresses in the cortical bone around the neck region of the implants in both bone models intensified and showed a homogeneous distribution.In both implant designs, under oblique and horizontal forces, stresses were observed in the cortical bone around the implants.While the highest tensile stress (Pmax) was observed more in the mesial and distal cortical bones in all models, the highest compression stress (Pmin) was detected in the buccal and lingual cortical bones. Conclusion Implants with conical body design gave better results in terms of stress distribution in bone compared to cylindrical implants. In our study, the D1 bone with the highest D1 cortical bone thickness met the incoming stresses better and provided a homogeneous distribution. D4 bone, which has the least cortical bone thickness and is the softest bone, could not meet the incoming forces well and therefore could not distribute it homogeneously. However, the results are within physiological limits for all groups.

Benzer Tezler

  1. Farklı geometrik özelliklere sahip endosteal implantların, farklı yoğunluktaki kemiklere uygulandığında ortaya çıkan değişikliklerin üç boyutlu modelleme ve sonlu elemanlar stres analizi ile değerlendirilmesi

    Evaluation of the results of endosteal implants with different geometric designs on stress distribution in different bone qualities with three dimensional finite element analysis

    MUSTAFA YALÇIN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2016

    Diş HekimliğiDicle Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. BEYZA KAYA

  2. Farklı implant tasarımlarının ve üst yapı materyallerinin implant ve implant çevre dokularında oluşturduğu stres dağılımının üç boyutlu sonlu elemanlar stres analizi yönetimi ile değerlendirilmesi

    Evaluation of the effect of different implant designs and prosthetic materials on stress distribution occurring on implant and surrounding periimplant tissues with three dimensional finite element analysis

    HAMİT FATİH ERKÜN

    Doktora

    İngilizce

    İngilizce

    2016

    Diş HekimliğiGazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. HANDAN YILMAZ

  3. Yüz defektlerinde kullanılabilecek farklı implant tasarımlarının kemikte oluşturduğu gerilmelerinin sonlu elemanlar analizi yöntemi ile değerlendirilmesi

    A finite element stress analysis of bone around a different implant design that can be used in facial defects

    BANU KARAYAZGAN

    Doktora

    Türkçe

    Türkçe

    2005

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. GÜLÜMSER EVLİOĞLU

  4. Aşırı atrofik mandibulada farklı implant tasarımlarının 3 boyutlu sonlu elemanlar analizi ile değerlendirilmesi

    The evaluation of various implant designs in severely atrophic mandible with 3d finite element analysis

    ÜNSUN ÇETİN

    Doktora

    Türkçe

    Türkçe

    2012

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BENGÜL YURDUKORU

  5. Biomedical design for improving the primary stability of dental implants in poor bone quality

    Kemik kalitesinin düşük olduğu durumlarda diş implantlarının birincil kararlılığının artırılmasına yönelik biyomedikal implant tasarımı

    SARKİS SÖZKES

    Yüksek Lisans

    İngilizce

    İngilizce

    2010

    BiyomühendislikBoğaziçi Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    PROF. DR. SABRİ ALTINTAŞ