Litotomi pozisyonunda retrograd intrarenal cerrahi geçirecek olan hastaların optik sinir kılıf çapının ultrasonografik olarak değerlendirilmesi
Evaluation of optic nerve sheath diameter by ultrasonography in patients undergoing retrograde intrarenal surgery in the lithotomy position
- Tez No: 870641
- Danışmanlar: DOÇ. DR. GÖZDE BUMİN AYDIN
- Tez Türü: Tıpta Uzmanlık
- Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
- Anahtar Kelimeler: Anesteziyoloji, Optik sinir, Ultrasonografi, Anesthesiology, Optic nerve, Ultrasonography
- Yıl: 2024
- Dil: Türkçe
- Üniversite: Sağlık Bakanlığı
- Enstitü: Ankara Etlik Şehir Hastanesi
- Ana Bilim Dalı: Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Çalışmamızda retrograd intrarenal cerrahi (RIRS) geçirecek olan hastalarda litotomi pozisyonu ile optik sinir kılıf çapı arasındaki ilişkinin araştırılması amaçlanmıştır. Gereç ve Yöntem: Litotomi pozisyonunda genel anestezi altında RIRS yapılacak 18-65 yaş arası ASA I-II 50 hasta çalışmaya dahil edildi. Rutin hemodinamik monitörizasyona (EKG, SpO2, Kan Basıncı, EtCO2) ek olarak BIS monitörizasyonu ile hastaların anestezi derinliği ölçüldü. İndüksiyon öncesi intravenöz midazolam (0.03-0.1 mg/kg) ile sedasyon sağlanarak hastaların bazal optik sinir kılıf çapları (OSKÇ) bilateral USG ile ölçülerek kaydedildi. Genel anestezi indüksiyonu intravenöz lidokain (1 mg/kg), propofol (2-3 mg/kg), fentanil (1 mcg/kg), roküronyum (0,2 mg/kg) ile yapıldı. İndüksiyon sonrası hastalara LMA yerleştirilerek mekanik ventilatörde VCV modda takip edilmeye başlandı. Anestezinin idamesinde inhalasyon anestezikleri ile %50 O2-%50 N2O karışımı kullanıldı. Hastaların OSKÇ ölçümleri USG eşliğinde tek bir uygulayıcı tarafından indüksiyon öncesi, LMA yerleştirilmesi sonrası 3. ve 5. dakikalarda litotomi pozisyonu verildikten sonra 3. ve 5. dakikalarda pozisyon düzeltilmeden önce ve hasta derlendikten sonra olmak üzere toplam 7 farklı zamanda bilateral olarak ölçülerek kaydedildi. Hastaların kalp hızı, kan basıncı, SpO2, ETCO2 ve BIS değerleri vaka boyunca belirli aralıklarla kaydedildi. Vaka sonunda cerrahi süre ve intravenöz verilen toplam mayi miktarı hesaplanarak kayıtlara eklendi. Bulgular: Hastaların cinsiyet, yaş, ASA skoru, ek hastalık, diyabet ve hipertansiyon varlığı, sigara içme durumu ve vücut kitle indeks değerlerine göre OSKÇ'ları arasında anlamlı farklılık görülmemiştir (p>0,05). İstatiksel olarak farklılık görülmese de, erkeklerin, ASA II skorlu olanların, diyabeti olmayanların ve hafif kilolu olan hastaların optik sinir kılıf çaplarının yüksek olduğu söylenebilir. Hastaların zamana bağlı olarak optik sinir kılıfı çapı değerleri arasında anlamlı farklılık görülmüştür (p<0,05). Farklılığın kaynağı incelendiğinde; hastaların genel anestezi öncesi bazal OSKÇ'na göre genel anestezinin 3. ve 5. dk, pozisyon verildikten sonraki 3. ve 5. dk, pozisyon düzelmeden önce ve derleme odasındaki OSKÇ'ları artış göstermiştir. Hastaların genel anestezinin 5. dk'sına göre, pozisyon verildikten sonraki 3. ve 5. dk'da, pozisyon düzeltilmeden önce ve derlenme odasındaki OSKÇ'ları artış göstermiştir. Sonuç: Sonuç olarak hem anestezi uygulamasının hem de pozisyon verme işleminin hastaların optik sinir kılıf çaplarının artmasında etkili olduğu görülmüştür. Bu nedenle litotomi pozisyonunda yapılacak ameliyatlarda ameliyat süresinin kısa tutulması ve kan basıncı gibi değişkenlerin sabit aralıkta tutulması gerekmektedir.
Özet (Çeviri)
Objective: In this investigation, we aimed to investigate the correlation between lithotomy position and optic nerve sheath diameter in patients undergoing retrograde intrarenal surgery. Materials and Methods: The study included fifty ASA I-II patients, aged 18-65 years, who were to undergo retrograde intrarenal surgery under general anesthesia in the lithotomy position. In addition to routine hemodynamic monitoring (ECG, SpO 2 , BP, ETCO 2 ), depth of anesthesia was measured by BIS monitoring. Prior to induction, the patients were sedated with intravenous midazolam (0.03-0.1 mg/kg) and basal optic nerve sheath diameters (ONSD) were measured and recorded by bilateral USG. Induction of general anesthesia was performed with intravenous lidocaine (1 mg/kg), propofol (2-3 mg/kg), fentanyl (1 mcg/kg), rocuronium (0.2 mg/kg). After induction, LMA was placed in the patients and they were started to be monitored in VCV mode on a mechanical ventilator. Inhalation anesthetics and 50% O 2 - 50% N 2 O mixture were used for maintenance of anesthesia. Optic nerve sheath diameter measurements of the patients were measured and recorded bilaterally by a single practitioner under USG guidance at a total of 7 different times: before induction, at 3 and 5 minutes after LMA placement, at 3 and 5 minutes after lithotomy position was given, before the position was corrected at 3 and 5 minutes, and after the patient was recovered. Heart rate, blood pressure, peripheral oxygen saturation, ETCO 2 and BIS values were recorded at regular intervals throughout the case. At the end of the case, the surgical time and the total amount of intravenous fluid given were calculated and added to the records. Results: There was no significant difference between the optic nerve sheath diameters of the patients according to gender, age, ASA score, presence of comorbidities, diabetes and hypertension, smoking status and body mass index values (p>0.05). Although there was no statistical difference, it can be said that optic nerve sheath diameters were higher in males, patients with ASA II score, patients without diabetes and patients who were slightly overweight. A significant difference was observed between the optic nerve sheath diameter values of the patients depending on time (p<0.05). When the source of the difference was examined; compared to the optic nerve diameter of the patients before general anesthesia, optic nerve diameters increased in the 3 rd and 5 th minutes of general anesthesia, in the 3 rd and 5 th minutes after positioning, before position recovery and in the recovery room. Compared to the optic nerve diameter at 5 minutes of general anesthesia, optic nerve diameters increased at 3 and 5 minutes after positioning, before position recovery, and in the recovery room. Conclusion: Both anesthesia administration and assuming the lithotomy position were found to be effective in increasing ONSD in patients. Therefore, in surgeries performed in the lithotomy position, the duration of the procedure should be kept short, and variables such as blood pressure should be maintained at a stable range.
Benzer Tezler
- Retrograd intrarenal cerrahide litotomi, t-tilt ve trendelenburg pozisyonlarının cerrahi sonuçlara etkisinin karşılaştırılması
Comparison of the effects of lithotomy, t-tilt, and trendelenburg positions on surgical outcomes in retrograde intrarenal surgery
ALİ SAİD KILIÇALP
Tıpta Uzmanlık
Türkçe
2026
ÜrolojiSağlık Bilimleri ÜniversitesiÜroloji Ana Bilim Dalı
PROF. DR. ÖMER FARUK BOZKURT
- Litotomi pozisyonunda klasik lma, proseal lma ve ı-gel'in respiratuar dinamikler açısından karşılaştırılması
Comparison of classic lma, proseal lma, i-gelaccording to respiratory dynamics at lithotomy position
GÖZDE DALAY
Tıpta Uzmanlık
Türkçe
2018
Anestezi ve ReanimasyonSağlık Bilimleri ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DOÇ. DR. GÖZDE BUMİN AYDIN
- Litotomi pozisyonunda açık abdominal cerrahi geçirecek hastalarda ısıtma sistemlerinin etkinliğinin karşılaştırılması
The comparison of two warming systems for the patients undergoing open abdominal surgery at lithotomy position
PINAR ÖZDEMİR YAŞAR
Tıpta Uzmanlık
Türkçe
2019
Anestezi ve ReanimasyonHacettepe ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DR. ÖĞR. ÜYESİ FİLİZ ÜZÜMCÜGİL
DOÇ. DR. ALMILA GÜLSÜN PAMUK
- Litotomi pozisyonunda operasyon süresinin alt ekstremite kas aktivitesi üzerine etkisi
Effect of operation time on lower extremity muscle activity in lithotomy position
BEYZA GEVREK
Yüksek Lisans
Türkçe
2021
Elektrik ve Elektronik MühendisliğiAkdeniz ÜniversitesiElektrik-Elektronik Mühendisliği Ana Bilim Dalı
PROF. DR. ÖMER HALİL ÇOLAK
- Litotomi pozisyonunda supraglottik havayolu aracı kullanılan hastalarda basınç kontrollü ve volüm kontrollü ventilasyon modlarının gastrik hacim üzerine etkisinin gastrik ultrason ile karşılaştırılması
Comparison of the effect of pressure-controlled and volume-controlled ventilation modes on gastric volume with gastric ultrasound in patients with supraglottic airway device in the lithotomy position
MELİKE ÇAĞATAY
Tıpta Uzmanlık
Türkçe
2024
Anestezi ve ReanimasyonSağlık Bilimleri ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
PROF. DR. AYŞİN SELCAN