Geri Dön

Comparison of retention values of different polyvinylsiloxane matrix materials on different types of patrices in implant-supported overdentures

İmplant destekli tam protezlerde farklı tiptekipatriksler üzerindeki farklı polivinil siloksan matriks materyallerinin retansiyon değerlerinin karşılaştırılması

  1. Tez No: 904177
  2. Yazar: İBRAHİM EMRE TOPRAKSEVEN
  3. Danışmanlar: PROF. İDİL DİKBAŞ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2024
  8. Dil: İngilizce
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı implant destekli tam protezlerde, ball, locator ve TiSi.snap ataşmanlar üzerinde matriks parçası olarak kullanılan dört polivinil siloksan (PVS) materyalinin retansiyon değerlerini, birbirleri ile ve geleneksel matrikslerinin retansiyon değerleriyle karşılaştırmaktı. Gereç ve Yöntemler: Her biri iki parçadan oluşan 140 örnek hazırlandı (n: 10). Numunelerin alt parçası, pleksiglasa dik olarak yerleştirilmiş iki implant analoğu ve bunların üstüne vidalanmış iki patriksten oluşuyordu. Bu patriks ataşmanlar ball (DTI İmplant Sistemleri, Türkiye), locator (DTI İmplant Sistemleri, Türkiye) ve TiSi.snap (Bredent GmbH & Co.KG, Almanya) idi. Numunenin matriks bileşenlerini içeren ve implant destekli bir tam protezi simüle eden üst parçası, polimetil metakrilat (PMMA) bloklardan frezelenerek elde edildi. Matriks olarak, tüm ataşman tipleri için dört farklı PVS materyali (Retention.sil 200, Retention.sil 400, Retention.sil 600 ve GC Reline II Soft), ball ve locator ataşmanlar için ilaveten geleneksel matriksleri kullanıldı. Her numune, bir termal döngüye ve çiğneme simülatöründe oklüzal kuvvet uygulamasına tabi tutuldu. Retansiyon değerleri, başlangıçta, 1 yıllık kullanım (1490 siklus) sonrasında ve 2 yıllık kullanım (2920 siklus) sonrasında kaydedildi. Bulgular: Ball ve locator ataşmanları için konvansiyonel matrisler PVS matriks materyallerinden anlamlı derecede daha yüksek retansiyon değerleri sağladı (p= 0,0001). Tüm gruplar arasında en yüksek retansiyon değeri (84,75 N), başlangıç ölçümünde ve ball ataşmanın konvansiyonel matriks ile kombine edilmesiyle elde edildi. Tüm patriks ve matriks kombinasyonları için, başlangıçtaki retansiyon değerleri kullanım süresi arttıkça orantılı olarak azaldı (p<0,05). PVS matriksleri arasında, tüm patriks grupları için, en yüksek retansiyon değeri Retention.sil 600 ile, en düşük retansiyon değeri ise Retention.sil 200 ile gözlendi. Sonuç: PVS matrisler, konvansiyonel matrikslere göre önemli ölçüde daha düşük retansiyon değerleri gösterdi. PVS matriks materyallerinin sertlik değerleri arttıkça başlangıç ölçümlerindeki retansiyon değerleri de arttı.

Özet (Çeviri)

Aim: The aim of this study was to compare the retention values of four polyvinyl siloxane (PVS) materials used as matrix parts over ball, locator and TiSi.snap attachments with the retention values of each other and conventional matrices in implant-retained overdentures. Materials and Methods: 140 specimens each consisting of two parts were prepared (n: 10). The lower part consisted of two implant analogs embedded perpendicularly in plexiglass and two patrices screwed on top of them. These patrix attachments were ball (DTI Implant Systems, Turkey), locator (DTI Implant Systems, Turkey), and TiSi.snap (Bredent GmbH & Co.KG, Germany). The upper part of the specimen containing the matrix components and simulates an implant-supported overdenture, was milled from polymethyl methacrylate (PMMA) blocks. As matrices, four PVS materials (Retention.sil 200, Retention.sil 400, Retention.sil 600, and GC Reline II Soft) were used for all attachment types, as well as conventional matrices for ball and locator attachments. Each specimen was subjected to thermal cycling, and occlusal force application in a chewing simulator. Retention values were recorded at initial, after 1 year of use (1490 cycles), and after 2 years of use (2920 cycles). Results: For ball and locator attachments, conventional matrices provided significantly higher retention values than PVS matrix materials (p= 0.0001). The highest retention value (84.75 N) among all groups was obtained when ball attachment combined with the conventional matrix at the initial measurement. For all patrix and matrix combinations, initial retention values decreased proportionally as the usage time increased (p<0.05). Among PVS matrices, the highest retention value was observed with Retention.sil 600, and the lowest with Retention.sil 200 for all patrix groups. Conclusion: PVS matrices showed significantly lower retention values than conventional matrices. As the hardness values of PVS matrix materials increased, the retention values at the initial measurements also increased.

Benzer Tezler

  1. In vitro comparison of the retention in two different implant abutment systems

    İki farkli dayanak sistemi üzerine yerleştirilen kronların tutuculuğunun kıyaslanması

    SARAH ALNMKI

    Yüksek Lisans

    İngilizce

    İngilizce

    2022

    Marmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  2. Çift kuron sistemlerinde farklı yöntemler ile üretilen örneklerin tutuculuklarının karşılaştırılması

    Comparison of retention forces of different fabrication methods in double crowns

    MELAHAT ÇELİK GÜVEN

    Doktora

    Türkçe

    Türkçe

    2016

    İstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  3. Farklı termoplastik retansiyon aygıtlarında in vivo şartlarda meydana gelen fiziksel değişikliklerin karşılaştırmalı olarak incelenmesi

    Comparison of physical changes in vivo for different thermoplastic retention devices

    HALİS ERDİNÇ KAYABAŞI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Süleyman Demirel Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...

  4. Dental implant yerleştirilmesinde kullanılan iki farklı frezin in vitro ortamda ısı oluşumu, primer stabilizasyon, yerleştirme ve çıkartma tork değerlerinin karşılaştırılması

    Comparison of heat generation, primary stabilization, placement and removal torque values of two different burs used in dental implant placement in in vitro environment

    KEREM ÜVEYS ÇÖMLEKÇİ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Selçuk Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    Yükleniyor...

  5. Farklı materyal ve tekniklerle üretilen implant abutment materyallerinin AFM ve SEM ile yüzey pürüzlülüklerinin karşılaştırılması ve mikrobiyolojik tutulumlarının incelenmesi

    Surface roughness comparison of implant abutments produced with different materials and techniques by AFM and SEM and investigation of microbiological retention

    SERTER MERT SELAMET

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Ege Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...