Geri Dön

Kardiyak pacemaker bulunan kalp yetersizliği hastalarının pacemaker kontrolünde bakılan sıvı takibi ile tanita cihazı ile ölçülen sıvı arasındaki korelasyonun araştırılması

Investigation of the correlation between fluid monitoring checked by pacemaker control and fluid measured by tanita device in heart failure patients with cardiac pacemakers

  1. Tez No: 930860
  2. Yazar: SEDAT ALTINTEPE
  3. Danışmanlar: PROF. DR. EZGİ KALAYCIOĞLU
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Kardiyoloji, Cardiology
  6. Anahtar Kelimeler: Kardiyak Pacemakerlar, Kalp Yetersizliği, Tanita Cihazı, Vücut Sıvı Takibi, Cardiac Pacemakers, Heart Failure, Tanita Device, Body Fluid Monitoring
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: Trabzon Ahi Evren Göğüs Kalp ve Damar Cerrahisi Eğitim ve Araştırma Hastanesi
  11. Ana Bilim Dalı: Kardiyoloji Ana Bilim Dalı
  12. Bilim Dalı: Kardiyoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Kardiyak Pacemaker Bulunan Kalp Yetersizliği Hastalarının Pacemaker Kontrolünde Bakılan Sıvı Takibi ile Tanita Cihazı ile Ölçülen Sıvı Arasındaki Korelasyonun Araştırılması Giriş: Kalp yetersizliği (KY) ile takip edilen hastalarda vücuttaki volüm yükünün artması hastanın klinik olarak dekompanse olmasına neden olmaktadır. Bu yüzden hastaların medikal tedavilerinin yeniden düzenlenmesi gerekmektedir. Bu çalışmada sıvı artışının öngörücüsü olarak biyoelektrik empedans analizi (BEA) yöntemini kullanan tanita cihazı ile sıvı takip sistemi özelliği olan kardiyak pacemakerlar (KPM) arasında korelasyon olup olmadığı araştırıldı. Yöntem: Çalışma prospektif ve kesitsel çalışmadır. Çalışmaya sıvı takip özelliği bulunan, KY nedeniyle KPM(ICD/CRT) implante edilen 57 hasta dahil edilmiştir. Hastalar KPM'de sıvı artışı olan ve sıvı artışı olmayan olarak iki gruba ayrıldı. Bu hastalarda Tanita cihazı ile vücut sıvı oranı ölçüldü ve karşılaştırıldı. Hastaların özgeçmişleri, laboratuar parametreleri, ekokardiyografi bulguları hastane bilişim sistemi ve e-nabız üzerinden kaydedilmiştir. Bulgular: Hastaların eş zamanlı bakılan pacemaker kontrolünde ve tanita cihazı sıvı ölçümünde sıvı artışı korelasyonu istatistiksel olarak anlamlı bulunmuştur (p<0.05). Sıvı artışı olan grubun ekokardiyagrafi bulgularına bakıldığında sağ kalp yetersizliği bulgularının olduğu görüldü. Vücüt kitle indeksi sıvı artışı olan grup lehine anlamlı olarak düşük olduğu saptanmıştır. KY süresi uzunluğu, AF sıklığı, antiaritmik medikal tedavi kullanımı sıvı artışı olan grup lehine anlamlı olarak daha fazla saptanmıştır. Demografik veriler, kullanılan ilaçlar, kardiyak pacemaker endikasyonları gruplar arasında benzer dağılım göstermektedir. Sonuç: Sıvı takip özelliği bulunmayan cihazlara sahip KY hastalarının medikal tedavi izlemleri ve hidrasyon durumları, BEA yöntemini kullanarak vücüt kompozisyon analizi yapan Tanita cihazları ile yapılabilir.

Özet (Çeviri)

nvestigation of the Correlation Between Fluid Monitoring Checked by Pacemaker Control and Fluid Measured by Tanita Device in Heart Failure Patients with Cardiac Pacemakers Introduction: In patients with heart failure (HF), increased body volume leads to clinical decompensation. Therefore, their medical treatments need to be readjusted. This study investigates the correlation between the Tanita device, which uses bioelectrical impedance analysis (BIA) to predict fluid increase, and cardiac pacemakers (CPM) with fluid monitoring systems. Method: This study is prospective and cross-sectional. Fifty-seven patients with HF who were implanted with CPMs (ICD/CRT) that include fluid monitoring features were included. Patients were divided into two groups based on whether they exhibited fluid increase or not in their CPM. Body fluid ratio was measured using the Tanita device and compared between the groups. Patient histories, laboratory parameters, and echocardiography findings were recorded through the hospital information system and the e-nabız system. Results: A statistically significant correlation was found between the fluid increase observed in CPM monitoring and the Tanita device fluid measurement (p<0.05). Echocardiographic findings of the group with fluid increase indicated signs of right heart failure. The body mass index was significantly lower in the group with fluid increase. The duration of HF, frequency of atrial fibrillation (AF), and the use of antiarrhythmic medical treatment were significantly higher in the group with fluid increase. Demographic data, medications used, and indications for cardiac pacemakers were similarly distributed between the groups. Conclusion: For HF patients with devices lacking fluid monitoring features, medical treatment follow-ups and hydration status can be managed using Tanita devices that perform body composition analysis through the BIA method.

Benzer Tezler

  1. Kalp pili elektrodlarının çıkarılmasında kullanılan iki farklı mekanik dilatör kılıfın akut ve uzun dönem etkinliğinin değerlendirilmesi

    Evaluation of acute and long term efficiency of two types mechanical dilatator sheath which is used in removal cardiac implantable devices' electrodes

    NİHAN BAHADIR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2019

    KardiyolojiHacettepe Üniversitesi

    Kardiyoloji Ana Bilim Dalı

    DOÇ. DR. UĞUR CANPOLAT

  2. Ekg'de frontal QRS-T açısının akut koroner sendromlarda grace ve tımı skorlamaları ile karşılaştırılması

    Comparison of the frontal QRS-T angle on ecg with grace and timi scores in acute coronary syndromes

    HAKAN İYİSARAÇ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Acil Tıpİzmir Katip Çelebi Üniversitesi

    Acil Tıp Ana Bilim Dalı

    DOÇ. DR. UMUT PAYZA

  3. Kardiyak resenkronizasyon tedavisi optimizasyonunda invaziv,elektrokardiyografik ve ekokardiyografik yöntemlerin karşılaştırılması ve akut dönemde hemodinamik verilere etkilerinin incelenmesi

    Optimization of cardiac resynchronization therapy in patients with heart failure secondary to ischemic or idiopathic dilated cardiomyopathy: Comparison of invasive, echocardiographic and electrocardiographic techniques

    BEGÜM YETİŞ SAYIN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    KardiyolojiBaşkent Üniversitesi

    Kardiyoloji Ana Bilim Dalı

    PROF. DR. MEHMET BÜLENT ÖZİN

  4. Yeni tanımlanan antropometrik indekslerin kardiyak cerrahi sonrası morbidite ve mortalite üzerine etkisi

    Impact of new anthropometric indices on mortality and morbidity after cardiac surgery

    MERVE ŞAHİNGÖZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Anestezi ve ReanimasyonErciyes Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. IŞIN GÜNEŞ