Farklı frezleme teknikleri ile uygulanan farklı morfolojiye sahip kısa implantların primer stabilite değerlerinin karşılaştırılması

Comparison of primary stability values of short implants with different morphology applied by different drilling techniques

  1. Tez No: 938150
  2. Yazar: ZAFER BERTAN BUYAN
  3. Danışmanlar: DOÇ. DR. RÜŞTÜ CEM TANYEL
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Kısa implant, Primer stabilite, Rezonans Sıklığı Analizi, Yerleştirme Torku, Apikal Olarak Genişletilebilir İmplant Tasarımı, Short Implants, Primary Stability, Resonance Frequency Analysis, Insertion Torque, Apically Expandable Implant Design
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Ağız, Diş, Çene Hastalıkları ve Cerrahisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Buyan ZB. Farklı Frezleme Teknikleri İle Uygulanan Farklı Morfolojiye Sahip Kısa İmplantların Primer Stabilite Değerlerinin Karşılaştırılması. İstanbul Üniversitesi Sağlık Bilimleri Enstitüsü, Ağız Diş ve Çene Cerrahisi ABD. Doktora Tezi. İstanbul. 2021. Çalışmamızın amacı farklı makrodesigndaki kısa implantların küçük çaplı frezleme tekniği ile uygulanmasının primer stabilite üzerine etkisinin yerleştirme torku ve rezonans frekansı analizi ile değerlendirmektir. Çalışmamızda aynı sığırdan elde edilmiş 4 adet kaburga kemiği kullanılmış ve toplam 20 osteotmi yapılmıştır. Grup 1 de Astra Tech OsseoSpeed TX 4.0-6 mm implantlar ve grup 2 de Dentack 4,1-6 mm implantlar için osteotomiler standart cerrahi protokol uygulanarak, grup 3'te Astra Tech OsseoSpeed TX 4.0-6 mm implantlar ve grup 4'te Dentack 4,1-6 mm implantlar için osteotomiler standart protokolun son frezi kullanılmadan küçük çaplı frezleme tekniği ile hazırlanmıştır. İmplantlar, torkmetre kullanılarak saat yönünde kuvvetle koronal kısımları kemik içerisinde kalacak şekilde osteotomilere yerleştirilmiş ve son yerleştirme tork değerleri kaydedilmiştir. Rezonans frekansı analizi için Osstell® ISQ (Osstell ISQ Integration Diagnostics AB, Göteborg, Sweden) cihazı kullanılmıştır. ISQ değerleri lateralden mediale olarak ölçülmüştür ve elde edilen veriler istatistiksel değerlendirme için kullanılmıştır. Grup 3'ün yerleştirme torku ve ISQ değerleri, Grup 1'den istatistiksel olarak anlamlı düzeyde yüksek bulunmuştur (p:0.028; p<0.05 , p:0.009; p<0.05). Grup 4'ün yerleştirme torku ve ISQ değerleri, Grup 2'den istatistiksel olarak anlamlı düzeyde yüksek bulunmuştur (p:0.009; p<0.05 , p:0.012; p<0.05). Grup 1'in yerleştirme torku ve ISQ değerleri, Grup 2'den istatistiksel olarak anlamlı düzeyde yüksek bulunmuştur (p:0.009; p<0.05). Yerleştirme torku ile ISQ değeri değerleri arasında pozitif yönlü, iyi düzeyde (%58.2) ve istatistiksel olarak anlamlı ilişki bulunmaktadır (p:0.007; p<0.05). Sonuç olarak; RFA ve yerleştirme torku ölçümleri aralarında pozitif korelasyon olan, implantların primer stabilitelerini değerlendirmek için kullanılabilecek güvenilir yöntemlerdir. Küçük boyutlu osteotomilere yerleştirilen kısa implantların makrodizayndan bağımsız olarak daha yüksek primer stabilite değerleri göstermesi küçük çaplı osteotomi tekniğinin etkinliğini kanıtlamaktadır.. Apikal olarak genişletilebilir kısa implant tasarımının primer stabilite üzerine etkisi beklediğimiz oranda olmamıştır. Ancak küçültülmüş osteotomilere yerleştirilen genişletilebilir kısa implantlar daha olumlu sonuçlar vermiştir. Genişletilebilir kısa implant tasarımını farklı makrodizayndaki implantlarla kıyaslayan çok sayıda çalışmaya ihtiyaç vardır.

Özet (Çeviri)

Buyan ZB. Comparison of Primary Stability Values of Short Implants with Different Morphology Applied by Different Drilling Techniques. İstanbul University, Institute of Health Science, Department of Oral and Maxillofacial Surgery. PhD Thesis. 2021. The aim of our study is to evaluate the effect of application of short implants in different macrodesign with undersized drilling protocol on primary stability with insertion torque and Resonance Frequency Analysis. In our study, 4 bovine ribs obtained from the same animal were used and 20 osteotomies were prepared. In group 1, osteotomies for Astra Tech OsseoSpeed TX 4.0-6 mm implants and in group 2 osteotomies for Dentack 4.1-6 mm implants were performed with standard surgical protocol ; in group 3 osteotomies for Astra Tech OsseoSpeed TX 4.0-6 mm implants and in group 4 osteotomies for Dentack 4.1-6 mm implants were performed with undersized drilling technique, by without using the end drill of the standard protocol. The implants were placed in the osteotomies with the coronal parts inside the bone by using a torque meter in a clockwise direction and the final insertion torque values were recorded. Osstell® ISQ (Osstell ISQ Integration Diagnostics AB, Göteborg, Sweden) device was used for resonance frequency analysis. ISQ values were measured from lateral to medial and the obtained data were used for statistical evaluation. The insertion torque and the ISQ values of Group 3 were found to be statistically significantly higher than group 1 (p: 0.028; p <0.05 , p: 0.009; p <0.05). The insertion torque and the ISQ values of Group 4 were found to be statistically significantly higher than Group 2 (p: 0.009; p <0.05 , p: 0.012; p <0.05). The insertion torque and ISQ values of Group 1 were found to be statistically significantly higher than group 2 (p: 0.009; p <0.05). There is a positive, good (58.2%) and statistically significant relationship between insertion torque and ISQ values (p: 0.007; p <0.05). As a result; RFA and insertion torque measurements are reliable methods that can be used to evaluate the primary stability of implants, with a positive correlation between them. The fact that short implants placed in undersized osteotomies show higher primary stability values, independent of the macro design, proves the effectiveness of the undersized osteotomy technique. The effect of the apically expandable short implant design on primary stability was not as expected. However, expandable short implants placed in reduced osteotomies yielded more positive results. There is a need for many studies comparing the expandable short implant design with different macro-design implants.

Benzer Tezler

  1. Eklemeli imalat ve kokil kalıba döküm teknikleri ile üretilen ısıl işlemsiz ve t6 ısıl işlemli durumdaki alsi10mg alaşımının yapısal, mekanik ve işlenebilirlik özelliklerinin araştırılması

    Investigation of structural, mechanical and machinability properties of alsi10mg alloy in as-built/as-cast and t6 heat treated condition manufactured by additive manufacturing and permanent mold casting techniques

    ERHAN ŞENTÜRK

    Doktora

    Türkçe

    Türkçe

    2026

    Makine MühendisliğiRecep Tayyip Erdoğan Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ŞENOL BAYRAKTAR

  2. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  3. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    ÜrolojiGazi Üniversitesi

    Üroloji Ana Bilim Dalı

  4. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Besin Hijyeni ve Teknolojisiİstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    DOÇ. DR. TÜRKAN KUTLUAY