Geri Dön

İki farklı ışık cihazı ile polimerize edilen üç farklı kompozitin renk stabiliteleri

Color stability of three different resin composites polymerized with two different light curing units

  1. Tez No: 963914
  2. Yazar: RUHSAN MÜDÜROĞLU ADIGÜZEL
  3. Danışmanlar: PROF. DR. ADİL NALÇACI
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental estetik, Dental materyaller, Kompozit reçineler, Nanokompozitler, Dental aesthetics, Dental materials, Composite resins, Nanocomposites
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Restoratif Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Son yıllarda kompozit rezin yapılarında önemli değişimler kaydedilmektedir. Buna rağmen renk stabilitesi hala bir problemdir ve estetik bozukluklar restorasyon yenilenmesinin en yaygın sebeplerinden biridir. Bu çalışmanın amacı iki tip ışık cihazının (QTH ve LED) 3 farklı kompozit rezin materyalin renk stabilitesine etkisi incelemektedir. A2 renginde 3 farklı kompozit rezin (Filtek Z550, Filtek Ultimate Flowable, Filtek Bulk Fill Posterior) materyalin her çeşidi için (5x2 mm) 30 adet örnek“Kompozit rezin-Işık kaynağı”kombinasyonuyla uygulandı. QTH ışık cihazı Hilux Ultraplus (Benlioğlu Dental, Ankara, Türkiye; 700mW/cm2) 40s ve LED Radii Plus Işık Cihazı (SDI Ltd, Victoria, Australia; 1400mW/cm2) 20s süreyle uygulanmıştır. İletilen enerji miktarının standardizasyonu için örnekler 28J/cm2' ye sabitlendi. Hazırlanan örnekler 6 ay boyunca yapay tükürükte saklandı. Renk ölçümleri polimerizasyondan hemen sonra, 24 saat, 7 gün, 15 gün, 1 ay, 3 ay ve 6 ay sonra bir kolorimetre cihazı (Minolta CR-321, Konica Minolta Sensing Pte Ltd, Singapore) yardımıyla yapıldı ve elde edilen değerler ışığında ∆E değerleri hesaplandı. Elde edilen verilerin istatistiğinde tek faktör tekrarlı üç yönlü varyans analizi (ANOVA) ve Bonferroni düzeltmesinden yararlanıldı (p<0,05). QTH ve LED ile polimerize edilen kompozitlerin ∆E değerleri incelendiğinde kompozitler arasında ve zamanlar arasında renk stabilitesinde istatistiksel olarak belirgin farklılıklar bulunmuştur (p<0,05). Fakat sabit enerji yoğunluğunda kompozitten bağımsız olarak QTH ve LED ışık cihazları karşılaştırıldığında 6. ay sonunda QTH ve LED ışık cihazları arasında istatistiksel olarak anlamlı bir fark bulunmamıştır (p>0,05). QTH ve LED ile polimerize edildiğinde çalışmamızda kullanılan kompozitler arasında 6 aylık periyot sonunda Filtek Z550 en küçük, Filtek Ultimate Flowable en yüksek renk değişimi (∆E) değerlerini göstermiştir. Tüm kompozitler 28J/cm2'lik sabit enerji yoğunluğu uygulandığında 6 aylık süre sonunda klinik olarak kabul edilebilir bir renk değişimi göstermiştir.

Özet (Çeviri)

In recent years significant developments has been recorded in resin composite structures. Despite these improvements, color stability remains a challenge and the esthetic problems are the most common factor of renewing restorations. This study aimed to evaluate the effects of two light curing units on the color stability of three different resin composite materials. Three different resin composite (Filtek Z550, Filtek Ultimate Flowable, Filtek Bulk Fill Restorative) with A2 color shade were prepared for each combination of composite resin-LCU (5x2 mm) for a total of 30 specimens. Specimens were irradiated with either QTH Hilux Ultraplus (Benlioğlu Dental, Ankara, Turkey; 700mW/cm2) for 40 seconds or Radii Plus LED Curing Light (SDI Ltd, Victoria, Australia; 1400mW/cm2) for 20 seconds. For the standardization of the amount of energy delivered, all specimens received 28J/cm2. All the specimens were stored in artificial saliva for six months. Color parameters were measured with a colorimeter (Minolta CR-321, Konica Minolta Sensing Pte Ltd, Singapore) after polymerization and at 24 hours, one week, one month, three months and six months. Color changes(∆E) was calculated among the different storage periods. All the statistical analyses were performed with three way ANOVA with one factor repeated and Bonferroni correction (p<0,05). Significant differences between composites and between the time periods were observed on the color stability with polimerized either QTH or LED. Independent from the composites there is no significant difference at the end of six moths between QTH and LED units with fixed energy density (p>0,05). Filtek Z550 restorative material showed the smallest and Filtek Ultimate Flowable restorative material showed the highest ∆E values at the end of six-month period between the materials used in our study. Clinically acceptable color changes were observed for all the materials at the end of six-month period with 28J/cm2 fixed energy density.

Benzer Tezler

  1. Farklı açılanmalarda tasarlanan modellerde polimerize edilen bir bulk fill kompozitin dönüşüm derecesi, su emilimi ve çözünürlük değerlerinin incelenmesi

    Examination of degree of conversion, water sorption and solubility values of a bulk fill composite polymerized with different tilt angles

    ASU NUR SANDIKÇI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiAkdeniz Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    PROF. DR. OSMAN TOLGA HARORLI

  2. Kompozit reçinelerin farklı ışık kaynakları ile polimerizasyonu sırasında oluşan ısısal değişikliklerin ve mikrosertliğin incelenmesi

    Investigation of thermal changes and microhardness of composite resins during polymerization by different light sources.

    HIDIR TATAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş Hekimliğiİstanbul Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BERNA TARIM

  3. Beyazlatıcı özelliğe sahip bir diş macununun farklı cila sistemleri kullanılarak bitirilen tek renkli kompozitlerin renk değişimi ve yüzey pürüzlülüğüne etkisi

    The effect of a whitening toothpaste on the color change and surface roughness of single-color composites finished using different polishing systems

    MURAT ŞENTÜRK

    Doktora

    Türkçe

    Türkçe

    2026

    Diş HekimliğiAtatürk Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. MERVE İŞCAN YAPAR

  4. Işık ile polimerize edilen kompozit rezinlerin polimerizasyon dönüşüm derecelerinin belirlenmesinde üç farklı yöntemin karşılaştırılması

    Comparing three different methods on determination of degree of conversion of three different composite resins

    CEREN KOSER

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiAnkara Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF. DR. ADİL NALÇACI

  5. Halojen ve led ışık kaynakları ile polimerize edilerek, farklı bitirme / polisaj teknikleri uygulanan iki farklı restoratif materyalin; yüzey sertliği, yüzey pürüzlülüğü ve biaksiyal fleksural dayanımlarının in vitro incelenmesi

    Polymerized with halogen and led light sources,two different restorative materials applied for different finishing / polishing techniques; in vitro investigation of surface hardness, surface roughness and biaxial flexural strength

    RÜYA ALPAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiSüleyman Demirel Üniversitesi

    Çocuk Diş Hekimliği Ana Bilim Dalı

    PROF. DR. ÇİĞDEM KÜÇÜKEŞMEN