Farklı braket slotlarında farklı derinliklere sahip ters spee eğrili nikel-titanyum tellerin alt keser, premolar ve molar dişler üzerine etkisinin sonlu elemanlar analizi ile değerlendirilmesi
Evaluation of the effect of reverse curved spee ni̇ckel-titanium wires with different depths in different bracket slots on lower incisors, premolars and molar teeth using finite element analysis
- Tez No: 977259
- Danışmanlar: DR. ÖĞR. ÜYESİ ESRA AĞAOĞLU MOGUL, PROF. DR. KORAY HALICIOĞLU
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Ortodontik teller, Yüksek mertebeli sonlu elemanlar, Orthodontic wires, Higher order finite elements
- Yıl: 2025
- Dil: Türkçe
- Üniversite: Biruni Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Ortodonti Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Ortodontik tedavilerde, artmış spee eğrisinin seviyelendirilmesi, ideal bir oklüzyon için önemli bir hedeftir. Bu tez çalışmasında, sonlu elemanlar analizi (SEA) kullanılarak ters spee eğrili Ni-Ti ark tellerinin farklı derinliklerde ve kalınlıklarda kullanıldığında, 0.018“ slot Roth ve 0.022”slot MBT braket sistemlerinde, mandibular dişlere uyguladığı kuvvetler ve periodontal ligament (PDL) üzerindeki stres dağılım SEA ile incelenmiştir. Çalışmada, 0.018'' slot boyutuna sahip Roth braketler ve 0.022'' slot boyutuna sahip MBT braketler için 20 mm, 25 mm ve 30 mm derinliklerde farklı boyutlarda ark telleri modellenmiştir. Belirlenen yükleme ve sınır koşulları altında, diş hareketlerinin X, Y ve Z eksenleri boyunca değerlendirilmesi, toplam yer değiştirme miktarının ölçülmesi ve PDL üzerindeki von Mises streslerinin incelenmesi amacıyla toplam 12 lineer statik analiz gerçekleştirilmiştir. Analiz sonuçlarına göre, 0.022 slot MBT braketlerinde 30 mm derinliğe sahip 0.019x0.025'' ve 0.021x0.025'' boyutlarındaki ters spee eğrili ark telleri ile 0.018 slot Roth braketlerinde 30 mm derinliğe sahip 0.017x0.025'' ve 0.016x0.022'' boyutlarındaki teller, en yüksek düzeyde kuvvet uygulayarak belirgin diş hareketleri ve PDL'de yüksek stres oluşumuna neden olmuştur. Buna karşılık, 0.022 slot MBT braketlerinde 20 mm derinliğe sahip 0.019x0.025'' ark teli ile 0.018 slot Roth braketlerinde 20 mm ve 25 mm derinliklerde kullanılan 0.017x0.025'' ve 0.016x0.022'' ark telleri daha dengeli kuvvet uygulayarak diş hareketlerini daha stabil bir şekilde yönlendirmiştir. Bu sonuçlar, ortodontik tedavi planlamasında hastanın periodontal sağlığını göz önünde bulundurarak en uygun tel-braket kombinasyonunun seçilmesi gerektiğini vurgulamaktadır. Uygulanan kuvvetin büyüklüğünün ve dağılımının dikkatlice değerlendirilmesi, tedavi sürecinde kök rezorpsiyonu ve periodontal hasar risklerini en aza indirmek için çok önemlidir.
Özet (Çeviri)
In orthodontic treatments, leveling an increased Curve of Spee is an important goal for achieving an ideal occlusion. In this thesis, finite element analysis (FEA) was used to examine the forces applied by reverse curve Spee Ni-Ti archwires with different depths and thicknesses on mandibular teeth and the stress distribution on the periodontal ligament (PDL) in 0.018“ slot Roth and 0.022”slot MBT bracket systems. In this study, archwires with different sizes were modeled at depths of 20 mm, 25 mm, and 30 mm for Roth brackets with a 0.018“ slot size and MBT brackets with a 0.022”slot size. Under specified loading and boundary conditions, a total of 12 linear static analyses were performed to evaluate tooth movements along the X, Y, and Z axes, measure total displacement, and examine von Mises stresses on the periodontal ligament (PDL). According to the analysis results, reverse curve Spee archwires with a depth of 30 mm and dimensions of 0.019x0.025'' and 0.021x0.025'' in 0.022 slot MBT brackets, as well as wires with a depth of 30 mm and dimensions of 0.017x0.025'' and 0.016x0.022'' in 0.018 slot Roth brackets, applied the highest level of force, leading to significant tooth movement and high stress on the PDL. In contrast, the 0.019x0.025'' wire with a depth of 20 mm in 0.022 slot MBT brackets and the 0.017x0.025'' and 0.016x0.022'' wires with depths of 20 mm and 25 mm in 0.018 slot Roth brackets applied more balanced and controlled forces, guiding tooth movements in a more stable manner. These findings emphasize the importance of selecting the most suitable wire-bracket combination while considering the patient's periodontal health in orthodontic treatment planning. Carefully evaluating the magnitude and distribution of the applied force is crucial to minimizing the risks of root resorption and periodontal damage during the treatment process.
Benzer Tezler
- Kontrol altındaki tip 1 diyabetli bireylerde diş hareketi sırasında rezorpsiyon markerlarının incelenmesi
Examination of resorption markers during tooth movement in individuals with controlled type 1 diabetes
ABDULLAH SEVMİŞ
Doktora
Türkçe
2021
Diş HekimliğiAydın Adnan Menderes ÜniversitesiOrtodonti Ana Bilim Dalı
DR. ÖĞR. ÜYESİ YAZGI AY ÜNÜVAR
- Farklı braket-kompozit kaide bağlantı yöntemlerinin, lingual braket tutuculuğuna olan etkilerinin in vitro olarak incelenmesi
In vitro investigation of various bracket-composite base treatment methods on bond strength of lingual orthodontic brackets.
BURAK AKSU
Doktora
Türkçe
2007
Diş Hekimliğiİstanbul ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. YILDIZ ÖZTÜRK ORTAN
- Farklı adeziv sistemlerinin ortodontik braket bağlanma dayanımlarına etkilerinin karşılaştırmalı olarak incelenmesi
Comparatively evaluation of the effects of various adhesive systems on shear bond strength of orthodontic brackets
HÜSEYİN ALKIŞ
Doktora
Türkçe
2011
Diş HekimliğiSüleyman Demirel ÜniversitesiOrtodonti Ana Bilim Dalı
DOÇ. DR. HAKAN TÜRKKAHRAMAN
- Farklı tipteki iingual braketler ile paslanmaz çelik teller arasındaki sürtünme dirençlerinin in vitro olarak değerlendirilmesi
A comparative in vitro study of frictional resistances between different lingual brackets and stainless steel archwires
TUĞÇE YURDAKULOĞLU ARSLAN
Doktora
Türkçe
2008
Diş Hekimliğiİstanbul ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. DR. YILDIZ ÖZTÜRK ORTAN
- Yüksek güçteki led ışık cihazının metal braketlerin bağlanma dayanıklılığı üzerine etkilerinin ın vitro olarak değerlendirilmesi
Evaluation of the effects of high power led on shear bond strength of metal brackets as in vitro
DERYA BAYKAL
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiEge ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. DR. ASLIHAN MEDİHA ERDİNÇ