Antropomorfik baş-boyun fantomunda 6 MeV elektron demetiyle verilen cilt dozunun PSD ve EBT3 film dozimetri yöntemleri ile incelenmesi ve TPS ile öngörülen dozla karşılaştırılması

Investigation of skin dose delivered by 6 MeV electron beam in an anthropomorphic head-neck phantom by PSD and EBT3 film dosimetry methods and comparison with the dose predicted by TPS

  1. Tez No: 1012927
  2. Yazar: AYŞENUR VARANOK
  3. Danışmanlar: PROF. DR. HALUK YÜCEL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyasyon Onkolojisi, Radiation Oncology
  6. Anahtar Kelimeler: Radyoterapi, Radiotherapy
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Radyoterapi, malign (kötü huylu) tümörlerin tedavisinde yüksek hassasiyetli doz aktarımını sağlayan etkili bir yöntemdir. Genellikle yüzeyel tümörlerde tercih edilen elektron demet tedavisi, sınırlı nüfuz etme (penetrasyon) derinliği sayesinde derin dokuların korunmasına olanak tanır ve dozun yüzeyden itibaren hızla azalmasını sağlar. Ancak tedavi planlama sistemleri (TPS), yüzeye yakın bölgelerde doku heterojenliği ve bolus malzeme etkisi nedeniyle cilde verilen doz tahminlerinde belirsizlikler oluşturabilir. Bu nedenle, yüzey cilt dozlarının güvenilir ölçümlerle değerlendirilmesi, kalite kontrol süreçleri açısından önem taşımaktadır. Bu tez çalışmasında, TPS ile planlanan 8 Gy cilt dozunun, Enstitüde 3D yazıcı tekniği ile geliştirilen antropomorfik baş-boyun fantomu üzerinde noktasal olarak Exradin A11 Roos tipi paralel plakalı iyon odası, Exradin W1 minyatür plastik sintilatör dozimetre (PSD) ve iki boyutlu olarak EBT3 radyokromik film (RFD) ile değerlendirilmesi amaçlanmıştır. Ölçümler, TRS-398 ve AAPM TG-51 protokollerine uygun şekilde kalibre edilerek, 6 MeV elektron enerjisinde, boluslu ve bolussuz koşullarda gerçekleştirilmiştir. Tedavi alanı dışındaki istemsiz dozlar da radyokromik film aracılığıyla incelenmiştir. Bulgular, ölçüm sistemleri arasında belirli farklılıklar olduğunu göstermiştir. PSD ile yapılan ölçümlerde, TPS doz hesaplamalarına kıyasla boluslu ve bolussuz uygulamalarda sırasıyla %3,4 ila %13,5 arasında sapmalar gözlenmiştir. RFD ile yapılan ölçümlerde ise %11,6 ila %29,5 arasında göreceli olarak daha büyük sapmalar göstermiştir. Bu sonuçlar, özellikle PSD yönteminin TPS ile daha uyumlu sonuçlar verdiğini, RFD'nin ise özellikle bolussuz durumda daha yüksek sapmalar gösterdiğini ortaya koymaktadır. Elde edilen sonuçlar tezde tartışılmıştır. Bu tez çalışması,“Antropomorfik Baş-Boyun Fantomu Geliştirilmesi ve Radyoloji ile Eksternal Radyoterapi Sistemlerinde Kullanım için Doz Dağılımlarının Plastik Sintilatör Dozimetre (PSD) ve Radyokromik Film Dozimetre (RFD) Teknikleriyle İncelenmesi”başlıklı ve 121F405 numaralı TÜBİTAK 1001 projesi kapsamında tam olarak desteklenmiştir.

Özet (Çeviri)

Radiotherapy is an effective method that enables high-precise dose delivery in treatment of malignant tumors. Electron beam therapy, mostly preferred for superficial tumors, allows for the protection of deeper tissues due to its limited penetration depth and results in a rapid dose fall-off. However, treatment planning systems (TPS) may present uncertainties in dose estimation, particularly in regions close to the surface, due to factors such as tissue heterogeneity and the use of bolus materials. Therefore, an accurate evaluation of skin doses through reliable measurements is of critical importance for quality assurance processes. In this thesis study, it is aimed at determining a planned 8 Gy skin dose by TPS on a developed anthropomorphic head-and-neck phantom using an Exradin A11 Roos parallel-plate ionization chamber, an Exradin W1 miniature plastic scintillator dosimeter (PSD) as a point-wise in one dimensional and EBT3 radiochromic film (RFD) as two dimensional. Measurements were conducted at 6 MeV electron energy under bolus and non-bolus conditions after calibration according to the TRS-398 and AAPM TG-51 protocols. In addition, unintended doses in out-of-field anatomical regions were analyzed using radiochromic film. The dosimetric findings showed somehow differences between the measurement systems. When compared to TPS dose calculations, PSD dose measurements are consistent with those TPS predicted dose results by 3.4% to 13.5% for skin dose with and without a bolus, respectively. In contrast, RFD measurements exhibited a relatively larger deviations from TPS dose results by 11.6% to 29.5%. These results suggest that PSD method agrees better with those of TPS, while RFD results showed significantly much higher relative deviations than those from TPS, especially without bolus. The obtained results is discussed in the thesis. This thesis study was fully supported within the scope of the TÜBİTAK 1001 project number 121F405 and titled“Development of an Anthropomorphic Head-and-Neck Phantom and Investigation of Dose Distributions Using Plastic Scintillator Dosimeter (PSD) and Radiochromic Film Dosimeter (RFD) Techniques in Radiology and External Radiotherapy Systems”.

Benzer Tezler

  1. Antropomorfik yetişkin baş-boyun fantomu geliştirilmesi, doz dağılımlarının plastik sintilatör dozimetre tekniği ile ölçülmesi ve monte carlo simülasyon yöntemiyle hesaplanan sonuçlar ile karşılaştırılması

    Development of an anthropomorphic adult HEAD-neck phantom, measurements of dose distributions by using plastic scintillator dosimetry and comparison of monte carlo simulation results

    GÖKBERK ÜNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Radyasyon OnkolojisiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. HALUK YÜCEL

  2. Tüm vücut ışınlamalarında farklı dozimetrik teknikler kullanılarak orta hat dozlarının belirlenmesi ve hesaplanan dozların doğrulanması

    Midplane dose determination and verification of calculated doses using various dosimetry techniques during total body ırradiation

    ÖZLEM ÖZDEMİR

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    OnkolojiEge Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. SERDAR ÖZKÖK

  3. Pediatrik radyolojide 5-9 yaş aralığında çocuk dozimetrisi fantomu geliştirilmesi için farklı malzemelerin doku eşdeğerliğinin CdTe X-ışın spektroskopi tekniğiyle incelenmesi ve bilgisayarlı tomografide standart fantomla elde edilen dozimetrik sonuçlarla karşılaştırılması

    Investigation of the characteristics of 5-9 years' age children tissue substitutes materials by using a CdTe semiconductor X-ray spectroscopy technique for construction of a tomographic dosimetry phantom in paediatric radiology and comparison with the dosimetric results from a standard phantom in Computed Tomography(CT)

    SENEM ZÜMRÜT DEMİREL

    Doktora

    Türkçe

    Türkçe

    2025

    Radyoloji ve Nükleer TıpAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. HALUK YÜCEL

  4. Human-like robot head design

    İnsan benzeri robot kafa tasarımı

    ORHAN ÖLÇÜCÜOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2007

    Makine MühendisliğiOrta Doğu Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. A. BUĞRA KOKU

    YRD. DOÇ. DR. E. İLHAN KONUKSEVEN

  5. X-ışını tanısal enerji aralığında polistren esaslı exradin W1 plastik sintilatör dedektörün doz tepkisinin incelenmesi

    Investigation of dose response of polystrene based exradin W1 plastic scintillator detector in X-ray diagnostic energy range

    NESLİHAN GÖKÇEK

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Radyoloji ve Nükleer TıpAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. HALUK YÜCEL