Geri Dön

İki farklı implant tipinde implant-dayanak birleşim arayüzeyindeki mikroaralık mikrosızıntı miktarının dinamik yükleme öncesi ve sonrası kıyaslanması

The comparision of microgap and microleakage findings before and after dynamic loading at the implant-abutment interface at two different implant systems

  1. Tez No: 129885
  2. Yazar: AYŞEGÜL ŞİRANLI
  3. Danışmanlar: DOÇ. DR. CİHAT ÇEKİÇ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental Implant, Dinamik Yükleme, Eksen Dışı Yükleme, Dental Implants, Cyclic Loading, Off-axis Loading
  7. Yıl: 2003
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protez Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Şiranlı, A., İki farklı implant tipinde implant-dayanak birleşim arayüzeyindeki mikroaralık ve mikrosızıntı miktarının dinamik yükleme öncesi ve sonrası kıyaslanması, Hacettepe Üniversitesi Sağlık Bilimleri Enstitüsü Protez Programı Doktora Tezi, Ankara, 2003. Bu çalışmada,“external hexed”ve“internal hexed”implant tiplerinde, dinamik yükleme öncesinde ve sonrasında mikroaralık ve mikrosızıntı değerleri in vitro koşullarda ölçülmüştür. Her iki implant grubundan 10'ar adet kullanılmıştır. Elde edilen değerler, hem gruplar arasında hem de her bir grupta dinamik yükleme öncesi ve sonrası değerleriyle kıyaslanmıştır. Yapılan ölçümler ve karşılaştırmalar referans alınarak implant-dayanak birleşim yüzeyinde oluşması beklenen eğilme momentinin mikrosızıntı üzerinde etkisinin olup olmadığı yorumlanmaya çalışılmıştır. Firma önerilerine göre sıkıştırılan implant dayanak komplekslerinin implant-dayanak birleşim arayüzeyindeki mikroaralık değerleri, SEM ile belirlenmiştir. İmplant vida odası tabanına partikül içermeyen kristal viyole boya konduktan sonra dayanaklar tekrar sıkıştırılarak Nutator üzerinde 10 saat boyunca bekletilmiştir. İmplant- dayanak arayüzeyinden sızan boyanın konsantrasyonları Spektrofotometre kullanılarak saptanmıştır. Daha sonra, tüm örnekler, vertikal eksenle 30° eğim yapacak şekilde, 4'erli gruplar halinde akrilik bir bloğa gömülmüş ve 10 saat boyunca 20 N ila 200 N arasında değişen sinosoidal dalga formunda dinamik yükleme uygulanmıştır. Yükleme esnasında oluşan mikrosızıntı değerleri kaydedildikten sonra yükleme sonrasında tüm örneklerin mikroaralık ölçümleri tekrarlanmıştır. Sonuç olarak, dinamik yükleme öncesi ve sonrası, mikroaralık ve mikrosızıntı değerleri implant grupları arasında karşılaştırıldığında istatistiksel olarak önemli bir fark bulunmamıştır. İmplant- dayanak birleşim arayüzeyi mikroaralık ve mikrosızıntı bulguları, dinamik yükleme yapmadan önceki ve sonraki değerleri ile karşılaştırıldığında ise hem external hexed implantlarda hem de internal hexed implantlarda istatistiksel olarak önemli fark bulunmuştur.

Özet (Çeviri)

VI ABSTRACT The comparision of microgap and microleakage findings with and without cyclic loading at the implant-abutment interface at two different implant systems, Hacettepe University Health Sciences Institude PhD Thesis in Prosthododntics, Ankara, 2003. In this in vitro study, microgap and microleakage values were measured on external hexed and internal hexed implant types before and after cyclic loading. The findings were compared both at between implant groups and within implant groups before and after cyclic loading. Taking the findings and the comparisions as a reference the effect of bending moments, on microleakage, was interpretted. The microgaps of implant-abutment complexes, which were torqued down according to the manufacturer's recommendations, were measured with SEM. After putting particle free crystal violet dye inside the screw chamber base of both implant systems, the abutments were retorqued down and the samples were put on a nutator for 10 hours. The amount of leaked dye concentrations from the l-A interface was measured with a spectrophotometer. Following this, all samples were placed on the plate with an angle of 30° to the vertical axis by using polymethyl acrilate and sinusoidal waveform cyclic loading was applied to the platform of the abutments for 10 hours with a cyclic between 20 N to 200 N. After finding out the microleakage values during dynamic loading, the microgaps of the samples were measured again. As a conclusion, the analysis of data variance resulted in no statistical significance for l-A interface gap and microleakage values in between implant groups. Statistical significance did result in the l-A interface gap and microleakage values by time interaction (before cyclic loading-after cyclic loading).

Benzer Tezler

  1. Darbeli elektromanyetik alanlar ile osteojenik indüksiyon (teorik, deneysel ve klinik çalışma)

    Başlık çevirisi yok

    ARSLAN BORA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1982

    Ortopedi ve TravmatolojiEge Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF. DR. MERİH EROĞLU

  2. İki farklı 3D daimi rezin ile üretilen diş destekli ve implant üstü kronların mekanik özelliklerinin karşılaştırılması

    Comparison of the mechanical properties of tooth-supported and implant-supported crowns manufactured using two different types of 3D permanent resin

    MUHAMMED BURAKCAN DOBAÇ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2026

    Diş HekimliğiAnkara Yıldırım Beyazıt Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. GÖKÇE ÜNSAL

  3. Farklı implant abutment bağlantı tiplerinin klinik performanslarının değerlendirilmesi

    Evaluation of clinical performance of different implant abutment connection TYPES

    ŞAZİYE ESRA GÖÇOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiSüleyman Demirel Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SERHAT SÜHA TÜRKASLAN

  4. İmplant üstü üç üyeli protezlerde dayanak tipi ve restorasyon materyalinin termomekanik yaşlandırma sonrası vida gevşemesi üzerine etkisi: İn vitro çalışma

    The effect of abutment type and restoration material on screw loosening after thermomechanical aging in implant-supported three-unit prostheses: An in vitro study

    ASLI BENGİSU KARAYEL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş HekimliğiHacettepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. RAGİBE ŞENAY CANAY

  5. Doğal diş implant destekli sabit protez uygulamalarında meydana gelen streslerin sonlu elemanlar analiz yöntemi ile karşılaştırılması

    Comparison of stresses occuring in natural tooth implant supported fixed prosthesis applications with finite element analysis method

    İPEK TEZEL

    Doktora

    Türkçe

    Türkçe

    2026

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. VOLKAN TURP