Geri Dön

Acil durum aydınlatması kaçış yolu aydınlık düzeyi minimum değerlerinin deneysel incelemesi

Emergency lighting experimental analyze of minimum values of escape route illuminance

  1. Tez No: 222283
  2. Yazar: MOEİN JAZAYERİ
  3. Danışmanlar: DOÇ.DR. DİLEK ENARUN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Mimarlık, İç Mimari ve Dekorasyon, Electrical and Electronics Engineering, Architecture, Interior Design and Decoration
  6. Anahtar Kelimeler: Aydınlatma, Acil Durum, Aydınlık Düzeyi, Kamaşma, Parıltı, Kaçış İşareti, Kaçış Yolu, Lighting, Emergency, Illuminance, Glare, Luminance, Escape Sign, Escape
  7. Yıl: 2007
  8. Dil: Türkçe
  9. Üniversite: İstanbul Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 135

Özet

Bu çalışmada Acil Durum Aydınlatması konusu bir bütün olarak ele alınarak incelenmiştir. Çalışmada acil durum aydınlatması ile ilgili mevcut standartlarda belirlenen aydınlık düzeyi değerleri ve kamaşma limitleri ve acil durum aydınlatma sistemlerinde kullanılan araçlar ve besleme sistemleri incelenmiştir. Tez çalışmasında ayrıca acil durum aydınltması için bazı hesaplama yöntemlerinden örnekler verilerek bu konu ile ilgili daha önce yapılmış olan ve acil durum aydınlatması için gerekli maksimum, minimum ve ortalama aydınlık düzeylerinin bulunması, kamaşma, parıltı faktörlerinin etkileri ve ışık kaynaklarının spektral güç dağılım aralıklarının acil durum aydınlatması üzerindeki etkilerinin bulunmasını amaçlayan çalışmalar incelenerek bu çalışmalardan elde edilen sonuçlar karşılaştırılarak yorumlanmıştır. Tez çalışmasının son bölümünde incelenen örnek çalışmalara benzer acil durum aydınlatma deneyleri yapılımş olup bu deneylerde teorik bilgiler ve standartlarda tavsiye edilen aydınlık düzeylerinin pratik olarak denenmesi ve sonuçta acil durum aydınlatması için insanların bulundukları mekanları güvenli bir şekilde terk edebilmeleri için en uygun aydınlık düzeyinin bulunması ve farklı aydınlık düzeylerinin acil durumlar sırasında insanlar üzerindeki etkilerinin incelenmesi amaçlanmıştır. Farklı aydınlık düzeyleri uygulanarak gerçekleştirilen bu deneylerden elde edilen sonuçlar büyük ölçüde daha önceki çalışmalardan elde edilen sonuçlara benzerlik göstermiş olup deneylerde deneklere uygulanan anketlerden elde edilen sonuçlar incelenmiş ve olumsuz yönlerinin bulunmasına rağmen yine de acil durum aydınlatması için özellikle mekanda bulunan kişilerin mekan ile aşina olmaları halinde 1 lx ortalama aydınlık düzeyinin insanların mekanı terk etmeleri için yeterli ve uygun bir aydınlık düzeyi olduğu sonucuna ulaşılmıştır.

Özet (Çeviri)

In this study Emergency Lighting subject is dealt with and examined as a whole. The study considers the illuminance values determined in present standards and glare limits as well as devices used in emergency lighting systems and feeding systems. The treatise equally exemplifies certain calculation methods for emergency lighting and considers the previous works aiming to determine the maximum, minimum and average illuminances necessary for emergency lighting, the effects of factors such as glare and luminance as well as the effects of spectral effects of light sources on emergency lighting and the results of these works have been compared and interpreted. In the last chapter of the treatise, experiments similar to the sample works that are studied and it was aimed to experiment the illuminances recommended in theoretical data and standards and consequently, to find the most suitable lighting levels so that people can leave their places securely and to study the effects of various illuminances on humans in emergency situations. The results obtained from these experiments are mostly similar to those obtained from these experiments and the results obtained from inquiry forms that were filled by volunteers in the experiments and it was found that an average illuminance equaling 1 lx is sufficient and suitable so that people can leave their places for emergency lighting in spite of the unfavorable aspects.

Benzer Tezler

  1. Acil durum kaçış güzergahı tasarımında aydınlatmanın önemi ve Halkalı kültürel tesis projesinin incelenmesi

    Importance of lighting in emergency escape route design and the investigation of the Halkali cultural facility project

    MELİKE TUNA

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    MimarlıkDüzce Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. AHMET CELAL APAY

  2. Alışveriş merkezlerindeki acil durum kaçış güzergahıtasarımının aydınlatma ve yönlendirme kriterleri bağlamında örnekler üzerinden incelenmesi

    Investigation of emergency escape route design in shopping malls in the context of lighting and guidance

    İREM MELİS DULUNDU

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    MimarlıkMimar Sinan Güzel Sanatlar Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. MUSTAFA ÖZGÜNLER

  3. Examination of fire safety measures taken in refunctioned hospital buildings

    Fonksiyon değişikliğine uğramış hastane yapılarında alınan yangın güvenlik önlemlerinin incelenmesi

    FURKAN ERUÇAR

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Mimarlıkİstanbul Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ NURİ SERTESER

  4. Akıllı bina otomasyon sistemleri ve Türkiye'deki uygulamaları

    Intelligent building automation systems and their applications in Turkey

    GÖKHAN AVİNCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. SERMİN ONAYGİL

  5. Hastanelerde elektrik tesisat uygulamalarının incelenmesi

    Examination of electrical installations in hospitals

    LÜTFİYE ERDOĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Biyomühendislikİstanbul Üniversitesi-Cerrahpaşa

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DOÇ. DR. AYSEL ERSOY YILMAZ