Statik ve dolgulu yıkayıcı sistemlerde H2S ve NH3 gideriminin deneysel incelenmesi
The experimental analysis of H2S and NH3 removal in static and packed scrubbing systems
- Tez No: 323150
- Danışmanlar: PROF. DR. DURMUŞ KAYA, PROF. DR. HALİL İBRAHİM SARAÇ
- Tez Türü: Doktora
- Konular: Makine Mühendisliği, Mechanical Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2012
- Dil: Türkçe
- Üniversite: Kocaeli Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 145
Özet
Bu çalışmada kirletici gideriminde verimi etkileyen faktörleri incelemek amacıyla bir gaz yıkayıcı sistemi tasarlanıp kurulmuştur ve simulasyon gazından hidrojen sülfür (H2S), karbondioksit (CO2) ve amonyak (NH3) giderimi üzerine farklı gaz debilerinde, farklı akış modunda ve farklı kirli gaz kompozisyonlarında deneysel incelemelerde bulunulmuştur. İçerisinde ticari dolgu malzemesi ve statik mikser bulunan iki farklı kolon kirletici giderimi bakımından karşılaştırılmıştır. Çalışmalarımızın ilk bölümünde dolgulu kolon ile H2S ve NH3 giderim deneyleri gerçekleştirilmiştir. H2S giderim veriminin en iyi sağlandığı yöntemin karşıt akışlı olduğu deney çalışmalarında gözlenmiştir. Dolgu malzemesi ile elde edilen deney sonuçlarına karşı kirletici giderimini iyileştirmeye yönelik araştırmalar yapılmıştır. Çapı dolgu malzemesine göre daha büyük, boşluk oranı yüksek ve yaklaşık dolgulu ile aynı hacimde olan bir statik mikser tarafımızdan tasarlanmıştır. Tasarladığımız bu statik mikser ayrı bir kolon içerisinde konumlandırılarak aynı deney koşullarında H2S giderim incelemeleri yapılmıştır. Statik mikserli kolon ile deney çalışmasında gaz hızının mevcut yapısal dolgulu kolondaki hıza göre az olması ile giderim veriminde yaklaşık %25 olumlu etki sağlamıştır. CO2 ve H2S'in bir arada bulunması gaz yıkayıcı kolonu boyunca sodyum hidroksit tüketimini artırdığından yüksek kirletici yüklerinde her iki kolonda da H2S giderim verimini azaltmaktadır. Deneysel çalışmalar sonucunda yıkayıcı sistemlerde kirletici gideriminde kalma süresinin de gaz hızı kadar etkili olduğu görülmüştür. Statik mikserli kolonda, 250-1000 ppmv kirletici konsantrasyonları arasında üç saniyelik veya üzeri bir gaz kalma süresinin optimum noktaya daha yakın olduğu gözlenmiştir.
Özet (Çeviri)
In this study, to investigate the factors on removal efficiency a scrubbing system has been designed and removal of hydrogen sulfide (H2S), carbondioxide (CO2) and ammonia (NH3) from simulated gas has been studied with different flow rates, flow modes and gaseous pollutant concentrations. Structured packing and static mixer in the two different columns are compared for removal of pollutants. In the first part of our investigation, H2S and NH3 removal has been studied with packed column. Better H2S scrubbing efficiencies have been obtained in countercurrent flow mode. Against to results which are obtained by packed column in experiments, studies were carried out to improve pollutants removal. We designed a static mixer which has larger diameter and void fraction than structured packing and has approximately same volume as packed column. Static mixer has been located in a separate column to investigate the H2S removal with same experimental conditions. Experiments with static mixer column, because of gas velocity is less than the structured packed column, has approximately 25% positive effect on removal efficiency. The coexistence of CO2 and H2S have been shown to increase the sodium hydroxide consumption along the scrubber column thereby decreasing the H2S removal efficiency at higher H2S loads in each column. The residence time is as effective as gas velocity in scrubbing systems to remove the gaseous pollutants has been shown in experimental studies. A gas residence times of equal or above 3 seconds were seemed to be closer to the optimum point in static mixer column between 250-1000 ppmv gaseous pollutant concentrations.
Benzer Tezler
- Metabolism of Turkish black tea phenolics by human gut microbiota
Siyah çay fenoliklerinin insan kalın bağırsak mikroflorası ile etkileşimi
EZGİ ÖZCAN
Yüksek Lisans
İngilizce
2014
BiyoteknolojiYeditepe ÜniversitesiBiyoteknoloji Ana Bilim Dalı
DOÇ. DR. FATMA YEŞİM KADIPAŞAOĞLU
YRD. DOÇ. DR. ÖZLEM GÜÇLÜ ÜSTÜNDAĞ
- Laparoskopik kolesistektomi operasyonu geçiren hastalarda üç farklı peep düzeyinin hemodinami, solunum mekaniği ve gaz değişimi üzerine etkilerinin karşılaştırılması
Comparison of the effects of 3 different PEEP levels on hemodynamics, respiratory mechanics and elimination of volatile anesthetic agent in patients undergoing laparoscopic cholecystectomy
HÜSNÜ MERT ARINALP
Tıpta Uzmanlık
Türkçe
2014
Anestezi ve ReanimasyonSağlık BakanlığıAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DR. GÜLŞAH KARAÖREN
DR. ÖMER TORUN ŞAHİN
- Tibia ve femur kırıklarında oymasız kilitli intramedüller çivi uygulamalarımız ve kliniğimiz sonuçları
The results of unreamed interlocking intramedullary nailing in long bone fractures
ALİ REİSOĞLU
Tıpta Uzmanlık
Türkçe
1999
Ortopedi ve TravmatolojiSağlık BakanlığıOrtopedi ve Travmatoloji Ana Bilim Dalı
DOÇ. DR. HALUK AĞUŞ
- Diyaliz hastalarında anemiyi ve eritropoietin direncini etkileyen parametreler
Factors affecting anemia and erythropoietin resistance in patients under dialysis
NEVİN AKÇAER ÖZTÜRK
Tıpta Uzmanlık
Türkçe
2003
NefrolojiBaşkent Üniversitesiİç Hastalıkları Ana Bilim Dalı
DOÇ. DR. SİREN SEZER
- Uyku yetersizliğinin anaerobik performans ve toparlanma sürecine etkisinin incelenmesi
Investigation of the effects of sleep deprivation on anaerobic performance and recovery process
KUTLU AYDIN
Doktora
Türkçe
2014
SporAbant İzzet Baysal ÜniversitesiAntrenörlük Eğitimi Ana Bilim Dalı
YRD. DOÇ. DR. ÜMİD KARLI