Radiation leakage and quality control tests of radiological diagnostic facility of hospitals in Erbil / Iraq
Irak/Erbi̇l'deki̇ hastanelerde radyoloji̇k tanilarda radyasyon kaçaklari ve kali̇te kontrol testleri̇
- Tez No: 398913
- Danışmanlar: YRD. DOÇ. DR. VURAL EMİR KAFADAR
- Tez Türü: Yüksek Lisans
- Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
- Anahtar Kelimeler: Radyasyon sızıntısı, kalite kontrol, X-ışını, Radiation leakage, Quality control, X-Ray
- Yıl: 2015
- Dil: İngilizce
- Üniversite: Gaziantep Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Fizik Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 88
Özet
X-ışını ve Bilgisayarlı Tomografi (BT) cihazlarının Erbil'deki hastanelerde yaygın olarak kullanımı ve acil durumlardaki teşhisler için halkın taleplerinin artması; bu teşhisleri yapan kişilerin kalite kontrol testlerinin yetersizliğine bağlı olarak fazla doza maruz kalmalarına sebep olmaktadır. Ayrıca, Erbil'deki konvensiyonel X-ışını ve BT cihazlarının radyasyon sızıntısı ve kalite kontrol testlerinin yeterince yapılmaması araştırmacıları bu konunun çalışılmasına yönlendirmiştir. Bu çalışmanın amacı Irak, Erbil'deki farklı bölgelerdeki hastanelerde X-ışını ve BT cihazları ile radyolojik teşhis yapılan hastanelerde radyasyon sızıntılarını belirlemektir. Bu çalışmada radyasyon sızıntı ölçümleri SOEKS 01M model Geiger-Müller sayacı ile yapılmıştir. 10 ayrı hastanede yapılan ölçüm sonuçlarına göre hastanelerin %64 'ünde düşük seviyede, %26'sı orta seviyede sızıntı tespit edilirken; %10 'nun ise iyi durumda olduğu belirlenmiştir. X-ışını cihazları için yıllık en yüksek ve en düşük değerler sırasıyla (18.13±9.72 mSv/yıl) ve (0.79±0.25 mSv/yıl), BT cihazları için ise yıllık (17.06±8.40 mSv/yıl) ve (1.01±0.19 mSv/yıl), olarak ölçülmüştür. Bazı bölgelerde ölçülen değerler oldukça yüksek olup, bu yerlerde radyasyondan korunma için gerekli önlemlerin alınması, yüksek dozlar için gerekli optimizayon faaliyetleri gerçekleştirilerek, değerlerin düşük seviyelere indirilmeleri gerekmektedir
Özet (Çeviri)
The expanded uses of X-ray and CT devices in Erbil hospitals and increasing public demand for such diagnoses within reason of frequent urgent needs, that lead to exposure of workers to additional doses during carrying out these diagnoses and due to the lack of Quality Control (QC) tests in those hospitals. Likewise, conventional X-ray and Computed Tomography (CT) equipment in Erbil not subjected to the detailed tests of radiation leakage and QC, the reason that urged the researcher to conduct this study. The study aimed to the assessment of Radiation Leakage in different location available and the QC tests of radiological diagnostic including X-ray and CT facilities of hospitals in Erbil / Iraq. In this study we used SOEKS 01M model Geiger-Müller radiation dosimeter to measure ionizing Radiation Leakage. The result shows that QC in X-ray facilities for the ten hospitals was 64% in Low level, 26% in moderate level and 10% in good condition. The highest and lowest amount of annual dose equivalent rates measured in radiological facilities were (18.13±9.72 mSv/yr) and (0.79±0.25 mSv/yr), respectively. Likewise, the amount measured regarding to the CT facilities were (17.06±8.40 mSv/yr) and (1.01±0.19 mSv/yr), respectively. Indicating that radiation exposure in some locations were highly variable. Hence, the much-increased contributions of X-Ray procedures to the Erbil city population dose indicate an urgent need to develop radiation protection and optimization activities for these high dose procedures to the low and accepted levels.
Benzer Tezler
- Endirekt düz panel dijital röntgen sistemlerinde kalite kontrol ve performans testleri
Quality control and performance tests in indirect flat panel digital X-ray systems
MELİKE EVCİN
Yüksek Lisans
Türkçe
2020
Fizik ve Fizik MühendisliğiKocaeli ÜniversitesiFizik Ana Bilim Dalı
PROF. DR. NALAN ÖZKAN GÜRAY
- Dijital mamografi cihazlarının kalite kontrol, kalibrasyon ve standardizasyonu
Quality control, calibration and standardization of full field digital mammography systems
OĞUZHAN AYRANCIOĞLU
Yüksek Lisans
Türkçe
2011
Radyoloji ve Nükleer TıpDokuz Eylül ÜniversitesiMedikal Fizik Ana Bilim Dalı
YRD. DOÇ. DR. AYŞEGÜL YURT
- MS ve MIS yapılarının gaz algılama özelliklerinin incelenmesi
Investigation of gas sensing properties of MS and MIS structures
FATİH DUMLUDAĞ
Doktora
Türkçe
2000
Fizik ve Fizik MühendisliğiMarmara ÜniversitesiFizik Ana Bilim Dalı
PROF. DR. ZAFER ZİYA ÖZTÜRK
- Hasat sonrası ultraviyole-A, B ve C radyasyonu uygulamalarının depolama süresince siyah havucun kalite parametrelerine etkisi
The effect of postharvest ultraviolet-A, B and C radiation applications on the quality parameters of black carrots during storage time
GİZEM PARÇA
Yüksek Lisans
Türkçe
2023
BiyolojiKocaeli ÜniversitesiBahçe Bitkileri Yetiştirme ve Islahı Ana Bilim Dalı
PROF. DR. REZZAN KASIM
- Bifurkasyon endogreft sistemi ile elektif infrarenal abdominal aort anevrizması endovasküler tamirinin erken dönem sonuçları
Başlık çevirisi yok
ONUR KARAHASANOĞLU
Tıpta Uzmanlık
Türkçe
2018
Göğüs Kalp ve Damar CerrahisiSağlık Bilimleri ÜniversitesiKalp ve Damar Cerrahisi Ana Bilim Dalı
DOÇ. DR. HAKKI ZAFER İŞCAN