Geri Dön

Implementing a nuclear power plant model for evaluating load-following capability on a small grid

Başlık çevirisi mevcut değil.

  1. Tez No: 401804
  2. Yazar: SAMET EGEMEN ARDA
  3. Danışmanlar: DR. KEITH E. HOLBERT
  4. Tez Türü: Yüksek Lisans
  5. Konular: Nükleer Mühendislik, Enerji, Nuclear Engineering, Energy
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2013
  8. Dil: İngilizce
  9. Üniversite: Arızona State Unıversıty
  10. Enstitü: Yurtdışı Enstitü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Özet yok.

Özet (Çeviri)

A pressurized water reactor (PWR) nuclear power plant (NPP) model is introduced into Positive Sequence Load Flow (PSLF) software by General Electric in order to evaluate the load-following capability of NPPs. The nuclear steam supply system (NSSS) consists of a reactor core, hot and cold legs, plenums, and a U-tube steam generator. The physical systems listed above are represented by mathematical models utilizing a state variable lumped parameter approach. A steady-state control program for the reactor, and simple turbine and governor models are also developed. Adequacy of the isolated reactor core, the isolated steam generator, and the complete PWR models are tested in Matlab/Simulink and dynamic responses are compared with the test results obtained from the H. B. Robinson NPP. Test results illustrate that the developed models represents the dynamic features of real-physical systems and are capable of predicting responses due to small perturbations of external reactivity and steam valve opening. Subsequently, the NSSS representation is incorporated into PSLF and coupled with built-in excitation system and generator models. Different simulation cases are run when sudden loss of generation occurs in a small power system which includes hydroelectric and natural gas power plants besides the developed PWR NPP. The conclusion is that the NPP can respond to a disturbance in the power system without exceeding any design and safety limits if appropriate operational conditions, such as achieving the NPP turbine control by adjusting the speed of the steam valve, are met. In other words, the NPP can participate in the control of system frequency and improve the overall power system performance.

Benzer Tezler

  1. Finite element simulation of visco-plastic deformation on micro-computers

    Başlık çevirisi yok

    CENGİZ SİNAN ÖZKAN

    Yüksek Lisans

    İngilizce

    İngilizce

    1989

    Orta Doğu Teknik Üniversitesi

    Yükleniyor...

  2. Sincan ilçesinde şeker pancarı tarımına yer veren işletmelerinin optimal işletme organizasyonlarının tespiti

    The Determination of the optimum farm organizations of the agricultural farms based on the sugar beet farming in Sincan district

    EYÜP SERİN

    Doktora

    Türkçe

    Türkçe

    1989

    Ankara Üniversitesi

    Tarım Ekonomisi Ana Bilim Dalı

    Yükleniyor...

  3. An Implementation and assessment of some of the boolean function minimization methods

    Başlık çevirisi yok

    MUCAHİT ÇELİKAĞ

    Yüksek Lisans

    İngilizce

    İngilizce

    1989

    Orta Doğu Teknik Üniversitesi

    Yükleniyor...

  4. Konaklama işletmelerinde stokların denetimi

    Başlık çevirisi yok

    SALİH SARAÇ

    Doktora

    Türkçe

    Türkçe

    1989

    İstanbul Üniversitesi

    Yükleniyor...

  5. A Study for investment decisions in mass housing construction in Turkey

    Başlık çevirisi yok

    TAHSİN BORA

    Yüksek Lisans

    İngilizce

    İngilizce

    1989

    Orta Doğu Teknik Üniversitesi

    Yükleniyor...