İmplant üstü dayanaklarda farklı koping üretim tekniklerinin kron tutuculuğuna ve marjinal uyuma etkisi: İn vitro çalışma
Effect of different coping production techniques on retention and marginal fit of implant supported crowns: An in vitro study
- Tez No: 408449
- Danışmanlar: DOÇ. DR. HASAN ÖNDER GÜMÜŞ
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: implant, dayanak, koping üretimi, kenar uyumu, tutuculuk, Dental bonding, Dental destekler, Dental implantasyon, Dental implantlar, Dental materyaller, Dental porselen, Dental restorasyon, Kronlar, İn vitro, implant, abutment, coping production, marginal fit, retention, Dental bonding, Dental abutments, Dental implantation, Dental implants, Dental materials, Dental porcelain, Dental restoration, Crowns, In vitro
- Yıl: 2015
- Dil: Türkçe
- Üniversite: Erciyes Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
İmplant destekli simante kron protezlerin uzun dönem tedavi başarısını belirleyen başlıca etkenler kenar uyumu ve pasif uyumdur. Çalışmamızın amacı farklı döküm kron üretim tekniklerinin kenar uyumu ve pasif uyumun bir göstergesi olan tutuculuk açısından karşılaştırılarak ideal kron altyapı üretim tekniğinin belirlenmesidir. Çalışmamızda implant destekli sabit protez metal altyapı üretiminde 4 farklı üretim tekniği ve 2 farklı implant markası karşılaştırılmıştır. Straumann koping, İmplance koping, İmplance CAD/CAM freze, İmplance SLA ve İmplance modelaj olmak üzere 5 grup oluşturuldu. Her grupta 10'ar adet olmak (n=10) üzere toplam 50 adet metal kron alt yapısı hazırlandı. Hazırlanan metal kron altyapıların dikey kenar aralığı ışık mikroskobu yardımı ile ölçüldü. Takiben örneklere simantasyon ve ısıl döngü işlemleri uygulandı ve sonrasında kenar aralığı ölçümü tekrarlandı. Her gruptan 1 adet örnek tarayıcı elektron mikroskopu analizi için ayrıldı ve kesitsel incelemeye tabi tutuldu. Kalan 45 örneğe tutuculuk testi uygulandı. Çalışmamızda yer alan gruplar içinde en düşük kenar aralığı değeri Straumann koping grubunda (88,54 - 97,48 μm) tespit edilirken en yüksek kenar aralığı değeri İmplance modelaj grubunda (186,27 -200,58 μm) gözlenmiştir. Farklı implant sistemlerinin kenar aralığına etkisi istatistiksel olarak anlamlı bulunmamıştır (p>0,05). Bütün gruplarda simantasyon ve ısıl döngü işlemleri öncesi ve sonrası kenar aralığı değerleri arasındaki fark istatistiksel olarak anlamlı bir artış olarak tespit edilmiştir (p<0,0001). Gruplar arası tutuculuk değerleri için en yüksek değer Straumann Koping grubunda en düşük değer İmplance Stereolitografi grubunda gözlenmiştir. Tarayıcı elektron mikroskobu gözleminde okluzal siman aralığı en yüksek koping gruplarında gözlenirken en düşük okluzal siman aralığı İmplance modelaj grubunda izlenmiştir.
Özet (Çeviri)
The main factors that determine the long-term treatment success of the implant-supported cemented crowns prosthesis are marginal fit and passive fit. The aim of this study is to evaluate marginal fit and retention of cast crown copings in different production techniques to determine the optimal production technique. In our study, we compared four different coping production techniques in implant-supported fixed prostheses and two different implant brands. Our study consists of five groups including Straumann coping, Implance coping, Implance CAD/CAM milling, Implance Streolithography and Implance Waxing. There were 50 metal crown copings which were divided equally into five groups (n = 10). Vertical marginal gaps of the prepared metal crown copings were measured with the aid of a light microscope. Vertical marginal gaps of the prepared metal crown copings re-measured following cementation and thermal cycling process. One sample from each group was selected randomly for scanning electron microscopy analysis and was subjected to cross-sectional views. Retention test was performed on remaining 45 samples. The lowest vertical marginal gap value was observed in Straumann coping group (88.54 - 97.48 μm) while the highest marginal gap was observed in Implance Waxing group (186,27 -200,58 μm). There was no statistically significant effect of different implant systems in terms of marginal gap results (p>0.05). There were statistically significant increase in marginal gap values after cementation and thermal cycles in all groups (p <0.0001). The highest retention value was measured in Straumann Koping group while the lowest was measured in Implance Stereolithography group. The highest occlusal cement gap value were observed in coping groups while the lowest was observed in Implance Waxing group in scanning electron microscopy analysis.
Benzer Tezler
- Köpeklerde aşil tendosu (achilles tendan) kopmalarının karbon fiber (carbon fibre) ve supramid ile dikilerek tedavisi üzerinde karşılaştırmalı araştırmalar
Başlık çevirisi yok
CELAL İZCİ
Doktora
Türkçe
1987
Veteriner HekimliğiAnkara ÜniversitesiVeterinerlik Cerrahisi Ana Bilim Dalı
PROF. DR. DOĞAN ASLANBEY
- Filtre edilebilme sayısı ile filtrasyon optimum dozunun araştırılması
Başlık çevirisi yok
HULUSİ ÇOKADAR
- Transformatör sargılarında oluşan hızlı değişimli geçici olayların incelenmesi ve enerji iletim sistemlerinin modellenmesinde yeni bir yaklaşım
Investigation of high speed transients on transformer windings and a new approach in modelling of energy transmission systems
A.OĞUZ SOYSAL
Doktora
Türkçe
1985
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiPROF. DR. M. KEMAL SARIOĞLU