Dental implant protetik üst yapı ataşman tutuculuğuna farklı protez temizleme solüsyonlarının etkisinin in vitro incelenmesi
In vitro evaluation of the effect of different denture cleaning solutions on the retention of the dental implant prosthetic superstructure attachment
- Tez No: 647888
- Danışmanlar: PROF. DR. TAYFUN BİLGİN
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2020
- Dil: Türkçe
- Üniversite: İstanbul Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 148
Özet
İmplant destekli tam protezler tam dişsiz bireylerin protetik tedavilerinde uygulanan ve geleneksel tam protezler ile karşılaştırıldığında daha iyi seviyede tutuculuk ve stabilizasyon sağlanabilen bir tedavi seçeneğidir. İmplant destekli tam protezlerde tutuculuk farklı ataşman sistemleri ile sağlanabilir. Seçilen tutucu sistemine göre değişmeksizin protez temizleme yöntemleri hastalara açıklanmalıdır. Bu çalışmanın amacı locator ve novaloc tutucu sistemlerinin farklı protez temizleme solüsyonlarında 6 aylık zamana eşdeğer olarak bekletilmesinin ardından 548 takma çıkartma siklusu uygulanarak retansiyon değerlerinin incelenmesidir. Tutucu parçalar locator sisteminde naylon içerikli ve novaloc sisteminde PEEK içeriklidirler. Her iki gruptaki lastikler tutuculuk kapasitelerine göre hafif, orta ve yüksek olmak üzere üç gruba ayrılmışlardır. 5 farklı protez temizleyici grubunun her birinde, her ataşman lastiği grubundan 8 adet lastik olmak üzere toplam 120 adet naylon lastik ve 120 adet PEEK lastik çalışmaya dahil edilmiştir. Dişi ve erkek parçalar akrilik rezin bloklara bağlanarak Instron Universal Test cihazında 50 N/sn kuvvet ile çekilerek yorma işlemi uygulanmıştır. Tutuculuk kuvvetleri ölçümleri gerçekleştirilmiştir. Deney sonunda da SEM görüntüleri alınmıştır. Çalışmamızın sonuçlarına göre NaOCl, PTF, AKT, CRG solüsyonlarında bekletilen örneklerde tutuculuk kuvvetlerinde istatistiksel olarak anlamlı azalma tespit edilmiş olup, distile suda bekletilen örneklerde tutuculuk kuvvet değişimi istatistiksel olarak anlamlı bulunmamıştır. NaOCl solüsyonda retansiyon kuvvet değerleri daha düşük tespit edilmiş olup L-şeffaf ve N-yeşil arasında tutuculuk değişimi bakımından istatistiksel olarak anlamlı ilişki bulunmuştur. Çalışmamızın sonucuna göre protez temizleyici solüsyonların, tutuculuğu sağlayan ataşmanlarda zaman içerisinde görülen retansiyon kuvvetlerinin azalmasına katkıda bulunduğu düşünülmektedir. Çalışmamızın gelecek çalışmalara ışık tutmasını, ağız ortamının taklit edilerek dinamik hareketler ile materyallerdeki yorgunluğun incelenebileceği çalışmalar ile geliştirilmesini umut etmekteyiz.
Özet (Çeviri)
Implant-supported complete dentures are a treatment option that can be applied in the prosthetic treatments of complete edentulous individuals and that can provide a better level of retention and stabilization compared to traditional complete dentures. Retention in implant-supported complete dentures can be provided with different attachment systems. Cleaning methods should be explained to patients regardless of the chosen retainer system. This study aims to examine the retention values by applying 548 insertion-removal cycle after the locator and novaloc holder systems are kept in different prosthesis cleaning solutions, equivalent to 6 months. Attachment parts are nylon in the locator system and PEEK in the novaloc system. Attachments in both groups are divided into three groups according to their holding capacity as light, medium, and high. In each of the 5 different denture cleaner groups, a total of 120 nylon, including 8 from each attachment group, and 120 PEEK were included in the study. Female and male parts were embedded into acrylic resin blocks and pulled with a force of 50 N / sec in the Instron Universal Test device, and fatigue test was applied. Retentive forces were measured. At the end of the experiment, SEM images were taken. According to the results of our study, a statistically significant decrease in retention strength was detected in samples kept in NaOCl, PTF, AKT, CRG solutions, and the change in retention strength in samples kept in distilled water was not found to be statistically significant. The retention strength values were lower in NaOCl solution, and a statistically significant relationship was found between L-transparent and N-green in terms of retention change. As a result of our study, denture cleaning solutions contribute to the reduction of retention forces seen in attachments over time. We hope that our study will shed light on future studies and will be developed with studies that can imitate the oral environment and examine fatigue in materials with dynamic movements.
Benzer Tezler
- Premaksilla ile tek taraflı maksiller defektlerin farklı tutucu türlerinde çevre dokulardaki stres, gerinim ve yer değiştirmenin üç boyutlu sonlu elemanlar stres analiz yöntemiyle değerlendirilmesi
With premaxilla and one side maxilla defect different upper structure types around surrounding tissue stress, evaluation stress and deplacement BY three di̇mension finite element analysis
CANAN AKAY
Doktora
Türkçe
2014
Diş HekimliğiGazi ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. ÖMER SUAT YALUĞ
- Maksiller defektlerde kuvvet dağılımının uygulanan implantların tip ve lokalizasyonlarına göre sonlu elemanlar analizi yöntemiyle değerlendirilmesi
Evaluating the distribution of force in maxillary defects according to the types and localizations of the implants by finite elements analysis method
FATİH MEHMET KORKMAZ
Doktora
Türkçe
2008
Diş HekimliğiGazi ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. SUAT YALUĞ
- Elmas benzeri karbon kaplamanın implant üstyapı parçaları arası galvanik korozyona etkinliğinin incelenmesi.
Efficiency of diamond like carbon coating on the galvanic corrosion between implant suprastuctures.
AHMET ÖZKÖMÜR
Doktora
Türkçe
2008
Diş HekimliğiÇukurova ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. TOLGA AKOVA
- İmplant destekli iki farklı sabit üst yapı tasarımının kemikte oluşturduğu stres dağılımının farklı kemik tiplerine göre değerlendirilmesi
Evaluation of the stress distribution generated by two different implant supported fixed superstructure designs in different bone types
NEŞET VOLKAN ASAR
Doktora
Türkçe
2006
Diş HekimliğiGazi ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF.DR. YAVUZ BURGAZ
- Çift taraflı atrofik mandibulada farklı kemik volümetrelerinde all-on-four tekniği ile yerleştirilen dental implantların çevre dokularda oluşturduğu streslerin sonlu elemanlar analizi ile incelenmesi
Evaluation of stress distribution around a dental implant with different amounts of bone by 'all on four' technique applied in bilateral atrophic mandible by using finite element analysis
OSMAN YAVUZ
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiDicle ÜniversitesiAğız Diş ve Çene Cerrahisi Ana Bilim Dalı
PROF. DR. BEYZA KAYA