Geri Dön

Farklı tekniklerle yerleştirilen yüksek viskoziteli cam iyonomer restoratif materyaller ve akışkan bulk-fill kompozit rezinin dentine makaslama bağlanma dayanımlarının ve mikro sertliklerinin değerlendirilmesi

Evaluation of the shear bond strength to dentine and micro hardness of high viscosity glass ionomer restorative materials and flowable bulk-fill composite resin placed by different techniques

  1. Tez No: 803376
  2. Yazar: MERVE NEZİR
  3. Danışmanlar: DOÇ. DR. SUAT ÖZCAN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 123

Özet

Bu tez çalışmasının amacı son dönemde klinik uygulamalarda sıklıkla tercih edilen iki farklı yüksek viskoziteli cam iyonomer restoratif materyal ile, bir akışkan bulk-fill kompozit rezin materyalin, farklı uygulama teknikleri (üretici firma talimatları, ön ısıtma uygulaması, ultrasonik aktivasyon uygulaması) sonrası materyallerin yüzey sertlik değerlerine (Vicker's sertlik testi) ve dentine makaslama bağlanma dayanımlarına etkisini değerlendirmektir. Vicker's sertlik testi için 4 mm derinliğinde ve 4 mm çapında teflon kalıplara; sırasıyla Grup 1: güçlendirilmiş yüksek viskoziteli cam iyonomer restoratif materyal (GYVCİS), Grup 2: yüksek viskoziteli cam iyonomer restoratif materyal (YVCİS) ve Grup 3: akışkan bulk-fill kompozit rezin (AB) üretici firma talimatlarına göre uygulandı. Sırasıyla Grup 1a: GYVCİS, Grup 2a: YVCİS ve Grup 3a: AB 50°C sıcaklıktaki su içinde 1 dk bekletilen materyallerden örnekler hazırlandı. Sırasıyla Grup 1b: GYVCİS, Grup 2b: YVCİS ve Grup 3b: AB yerleştirme esnasında 5 sn ultrasonik aktivasyona maruz bırakıldı. Sırasıyla Grup 1c: GYVCİS, Grup 2c: YVCİS ve Grup 3c: AB 50ºC'de su içerisinde 1 dk bekletildikten sonra ultrasonik aktivasyon yardımı ile uygulandı. Polimerizasyon veya sertleşme reaksiyonu tamamlanan örneklerin üst yüzeylerinin Vicker's sertlik değerleri Vicker's sertlik ölçüm cihazı ile ölçüldü. Makaslama bağlanma dayanımı testi için çalışmaya 84 adet çekim endikasyonu bulunan sağlam insan molar dişi dahil edildi. Dişler yavaş dönen elmas kesici yardımı ile meziodistal yönde ikiye ayrıldı. Örnekler rastgele 12 gruba (n=14) ayrıldı. Materyaller; Vicker's sertlik testinde kullanılan yerleştirme teknikleriyle dentin yüzeyine uygulandı. Örnekler 36,5°C'de etüvde 24 saat distile su içerisinde bekletildi. 24 saatin sonunda örneklere makaslama bağlanma dayanımı testi uygulandı. Çalışmada elde edilen bulguların istatistiksel analizi tek yönlü varyans analizi (ANOVA) ve Tukey çoklu karşılaştırmaları kullanılarak gerçekleştirildi (p= 0,05). AB grupları hem Vicker's sertliği hem de makaslama bağlanma değerleri açısından diğer iki farklı cam iyonomer esaslı materyallere oranla anlamlı oranda daha yüksek değerler gösterdi (p

Özet (Çeviri)

The aim of this study was to compare the different application methods (manufacturer's instructions, preheating application, ultrasonic activation application) of two different high-viscosity glass ionomer restorative materials and a flowable bulk-fill composite resin material, on surface Vicker's hardness values and the shear bond strength to dentine. For the surface Vicker's hardness test 4 mm depth and 4 mm diameter teflon mold were used. For Group 1: reinforced high viscosity glass ionomer restorative material (GYVCİS), Group 2: high viscosity glass ionomer restorative material (YVCİS) and Group 3: flowable bulk-fill composite resin (AB) were applied according to the manufacturer's instructions. For Group 1a: GYVCİS, Group 2a: YVCİS and Group 3a: AB specimens were prepared from materials that were kept in water at 50°C for 1 minute. Group 1b: GYVCIS, Group 2b: YVCIS and Group 3b: AB were exposed to ultrasonic activation for 5 seconds during placement. For Group 1c: GYVCIS, Group 2c: YVCIS and Group 3c: AB were kept in water at 50ºC for 1 minute and then 5 second ultrasonic activation were applied during placement. Surface Vicker's hardness values of the upper surfaces of the specimens were measured using Vicker's hardness measuring device. For the shear bond strength test, 84 intact human molar teeth with extraction indications were included in the study. The teeth were sectioned two in the mesiodistal direction with a slow speed diamond saw. The specimens were randomly divided into 12 groups (n=14). Materials were applied to the dentin surfaces with the some placement protocols as used in the Vicker's hardness test. The specimens were kept in distilled water for 24 hours in at 36.5°C. At the end of 24 hours, shear bond strength test was performed. Statistical analysis were performed using one-way analysis of variance (ANOVA) and Tukey multiple comparisons for both Vicker's hardness and for shear bond strength tests (p= 0.05). AB groups showed significantly higher values in terms of both Vicker's hardness and shear bond values compared to the other two different glass ionomer based materials (p

Benzer Tezler

  1. Ağız içi ve masaüstü tarayıcılar kullanılarak elde edilen CAD/CAM kuron restorasyonlarında iç uyumun in-vitro olarak incelenmesi

    In vitro evaluation of marginal and internal fit of CAD/CAM crowns by using intraoral and extraoral scanners

    GÜLİZ KILINÇOĞLU

    Doktora

    Türkçe

    Türkçe

    2014

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SAMİM ÇETİN SEVÜK

  2. Investigation of microstructure movement under flow by using image processing and deep learning

    Akış altındaki mikroyapı deformasyonunun görüntü işleme ve derin öğrenme kullanılarak incelenmesi

    SAEED SARBAZZADEH KHOSROSHAHI

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ AHMET CAN ERTEN

  3. Blood flow and measurement techniques

    Kan akışı ve ölçüm teknikleri

    AYŞE KANDEMİR AKALIN

    Yüksek Lisans

    İngilizce

    İngilizce

    1995

    Enerjiİstanbul Teknik Üniversitesi

    PROF.DR. OSMAN F. GENCELİ

  4. Young's modulus characterization of polydimethylsiloxane (PDMS) microfluidic chips for viscosity measurements

    Viskozite ölçümleri için tasarlanmış polidimetilsiloksan (PDMS) mikroakışkan çiplerinin young modülü karakterizasyonu

    CEYDA KÖKSAL

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Biyomühendislikİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ AHMET CAN ERTEN

    DOÇ. ONUR FERHANOĞLU

  5. Simulation of separated flow around cylinders

    İz akışları ve izin kontrolü

    ALİ RUHŞEN ÇETE

    Yüksek Lisans

    İngilizce

    İngilizce

    1995

    Uçak Mühendisliğiİstanbul Teknik Üniversitesi

    PROF.DR. M. FEVZİ ÜNAL