Halcyon linak ve düzleştirici filtresiz geleneksel c kollu linak cihazlarının meme radyoterapisi planlarının karşılaştırılması

Comparison of breast radiotherapy plans with halcyon linac and traditional c-arm linac devices using flattening filter free beams

  1. Tez No: 822491
  2. Yazar: KUDRET AKÇAY
  3. Danışmanlar: DR. ÖĞR. ÜYESİ MUSTAFA ÇAĞLAR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: İstanbul Medipol Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 99

Özet

Bu çalışmada konvansiyonel linak sistemleri ile yeni bir tasarıma sahip Halcyon linak sisteminin meme radyoterapisi uygulamalarındaki çeşitli teknik ve dozimetrik performanslarının karşılaştırılması amaçlanmıştır. Bu çalışmaya birbirleriyle uyumlu, DIBH tekniğiyle tomografisi çekilmiş retrospektif olarak seçilen beş sol meme radyoterapisi alan hasta dahil edilmiştir. Ayrıca insan benzeri antropomorfik fantom ile meme radyoterapisi simülasyonu yapılarak seçilen hastalara benzer planlama çalışmaları yapılmıştır. Her bir hasta için TrueBeam (TB) ve Halcyon (HC) cihazlarında 3BKRT (3 Boyutlu Konformal Radyoterapi) ve VMAT (hacimsel ayarlı ark tedavisi) tekniği kullanılarak toplam 20 tedavi planlanması yapılmıştır. Akabinde insan görünümlü antropomorfik fantom kullanılarak her iki cihazda her iki teknik kullanılarak tedavi planı yapılmıştır. TB planları için 6 MV düzleştirici filtreli ve HC için ise 6 MV düzleştirici filresiz foton enerjileri kullanılmıştır. Hasta planları kullanılarak TPS üzerinden çeşitli cihaz parametreleri (MU, BeamOn Time gibi) ve dozimetrik parametreler (CI, HI, PTV ve OAR'ların) cihaz ve tekniklere göre karşılaştırılmıştır. Atropomorfik fantom kullanılarak ise OSL dozimetri yöntemi kullanılarak tedavi esnasındaki yüzey dozları her iki cihaz ve her iki teknik için ayrı ayrı ışınlanarak ölçülmüştür. Hastalar için yapılan planlarda TB ve HC cihazının dozimetrik olarak karşılaştırılmasında benzer sonuçlar elde edilmiştir. HC cihazında yapılan planlarda ortalama kritik dozlarda daha etkili olduğu görülmüştür. Fantom OSL ışınlamalarında ise OSL'de okunan değerlerle planlar arasında cilt dozunda ve lenslerde farklılık görülmüş.

Özet (Çeviri)

In this study, it was aimed to compare the various technical and dosimetric performances of the conventional linac systems and the newly designed Halcyon linac system in breast radiotherapy applications. Five retrospectively selected left breast radiotherapy patients who were compatible with each other and whose tomography was performed using the DIBH technique were included in this study. In addition, similar radiotherapy plans with selected patients were simulated on a human-like anthropomorphic phantom. A treatment plan was made for each patient using the 3DCRT (Three-Dimensional Conformal Radiation Therapy) and VMAT (Volumetric modulated arc therapy) technique on the TrueBeam (TB) and Halcyon (HC) device, and a total of 20 treatment plans were created. Subsequently, treatment plans were made using both techniques on both devices on human-looking anthropomorphic phantom. 6 MV flattening photon beams for TB and 6 MV flattening filter free photon beams for HC were used. Using patient plans, various device parameters (such as MU, BeamOn Time) and dosimetric parameters (CI, HI, PTV and OARs) were compared according to devices and techniques over TPS. Surface doses were measured during treatment for each device and technique using the OSL dosimetry method on the atropomorphic phantom. Similar results were obtained in the dosimetric comparison of the TB and HC device in patient plans. It has been observed that the plans made on the HC device are more effective at average critical doses. In phantom OSL irradiations, differences in skin and lens doses were observed between planned and administered doses.

Benzer Tezler

  1. Vestibular Schwannoma tanılı hastaların radyoterapi tedavisinde stereotaktik radyocerrahi planlarının farklı tedavi cihazlarında dozimetrik karşılaştırılması

    Dosimetric comparison of stereotactic radiosurgery plans on different treatment devices in radiotherapy treatment of patients with vestibular Schwannoma

    EBRU ŞİMŞEK

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Fizik ve Fizik Mühendisliğiİstanbul Medipol Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    PROF. DR. HİLAL ACAR DEMİR

  2. İntrakranial tümörlerin Halcyon cihazı ile yoğunluk ayarlı volumetrik ark ışınlamalarında plan kalitesinin araştırılması

    Evaluation of plan quality for intracranial tumors treated in intensity-modulated volumetric arc radiotherapy with Halcyon

    SELEN ENER

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE BECERİR

  3. Özofagus kanserlerinin yoğunluk ayarlı volümetrik ark ışınlamalarında halcyon ve trilogy cihazı ile hazırlanan planların karşılaştırılması

    Treatment planning comparison of volumetric modulated arc therapy with the halcyon and the trilogy for esophageal cancers

    SİNEM ÖZDEN POLAT

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Radyasyon Onkolojisiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE BECERİR

  4. Serviks tümörlerinin radyoterapisinde günlük çıkış dozlarının epıd dozimetrisiyle araştırılması

    Investigation of daily transit image in radiotherapy of cervical tumors using epid dosimetry

    DİCLE ADIGÜZEL

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Radyasyon Onkolojisiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE BECERİR

  5. Dicle Üniversitesi kampusu'nun kuşları

    Ornithofauna of Dicle University campus

    ENGİN GEM

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    BiyolojiDicle Üniversitesi

    Biyoloji Ana Bilim Dalı

    PROF.DR. MURAT BİRİCİK