Farklı endodontik giriş kavitesi açılan mandibular molar dişlere termodöngü uygulandıktan sonra kırılma dirençlerinin karşılaştırılması
Comparison of fracture resistance of mandibular molar teeth with different endodontic access cavities after thermocycling
- Tez No: 844435
- Danışmanlar: DOÇ. DR. ADİLE ŞEHNAZ YILMAZ
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2023
- Dil: Türkçe
- Üniversite: Çukurova Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Endodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 72
Özet
Endodontik tedavi görmüş dişlerin kırılma direnci, vital dişlere göre daha düşüktür. Geleneksel endodontik kavite tasarımlı dişlerde, önemli ölçüde dentin kaybına bağlı olarak fonksiyon sırasında dişlerin kırılma direncini azalır. Bu çalışmanın amacı, kompozit rezin ile restore edilmiş ve termodöngü uygulanmış mandibular molar dişlerde farklı endodontik kavite tasarımlarının kırılma direncine olan etkisini karşılaştırmaktır. Toplam 50 adet yakın zamanda çekilmiş, çürüksüz mandibular molar diş toplandı. Konik ışınlı bilgisayarlı tomografi ile görüntülendi ve kök kanal morfolojileri göz önüne alınarak dişler kontrol (n=8) ve 3 test grubuna (n=14) ayrıldı. Grup1 kontrol, grup2 geleneksel endodontik kavite (GEK), grup3 truss (kafes) endodontik kavite (TREK) ve grup4 ninja (ultrakonservatif) endodontik kavite (NEK) olacak şekilde ayrıldı. Giriş kavitesinin gruplarda belirtildiği şekilde hazırlanmasından sonra, tüm dişlerin kontrol grubu hariç WaveOne Gold eğeleriyle (Dentsply Maillefer, Ballaigues, İsviçre) kanal preparasyonu yapıldı ve %1,25 sodyum hipoklorit ile irigasyonu yapıldı. Kök kanalları Waveone Conform Fit gutta perka ve AHplus kanal patı kullanılarak tek kon tekniği ile dolduruldu. Giriş kaviteleri kompozit ile restore edildi. Tüm dişler daha sonra 5°C ile 55°C arasında 60 saniye boyunca 1200 ısıl döngüye tabi tutularak 6 ay yaşlandırıldı. Örnekler, 1 mm/dk hızda 2,5 mm çapında yuvarlak uçlu bir pistona sahip evrensel bir yükleme makinesinde (Testometric, M500-25kN, İngiltere) kırılmak üzere yüklendi ve kırılma değerleri Newton cinsinden kaydedildi. Veriler tek yönlü ANOVA varyans analizi ve çoklu karşılaştırmalar için Tukey post hoc analizi ile analiz edildi (P
Özet (Çeviri)
The fracture resistance of endodontically treated teeth is lower than vital teeth. In traditional endodontic cavity design, the fracture resistance of teeth during function is reduced due to significant dentin loss. The aim of this study is to compare the effect of different endodontic cavity designs on fracture resistance in mandibular molar teeth which were restored with composite resin and thermocycled. A total of 50 freshly extracted, caries-free mandibular molar teeth were collected. All of the sampleswere visualized by cone-beam computed tomography, and the teeth were divided randomly into control (n=8) and 3 test groups (n=14) based on root canal morphology. No treatment was performed to Group1 (control). In Group 2; traditional endodontic cavity (GEK) was prepared, in Group 3; truss (cage) endodontic cavity (TREK) was prepared, and in group 4 ninja (ultraconservative) endodontic cavity (NEK) was prepared. After the access cavity preparation were completed as mentionedin the groups, root canals were prepared with WaveOne Gold files (Dentsply Maillefer, Ballaigues, Switzerland) and irrigated with 1.25% sodium hypochlorite. Root canals were filled with the matched cone technique using Waveone Conform Fit gutta-percha (Dentsply Maillefer, Switzerland) and AH-Plus canal sealer (Marka, şehir, ülke). Access cavities were sealed with composite resin. All teeth were aged for 6 months by subjecting to 1200 thermal cycles for 60 seconds between 5°C and 55°C in a chewing simulator. Fracture test was conducted immediately after aging with a Testometric test device (Testometric, M500-25kN, UK) at a cross-head speed of 1 mm/sec. with a 2.5 mm diameter round-tipped piston and the fracture values were recorded as Newtons. Data were analyzed by one-way ANOVA analysis of variance and Tukey post hoc analysis for multiple comparisons (P
Benzer Tezler
- Farklı eğe sistemlerinin etkinliklerinin mikro-CT ile incelenmesi
Investigation of the efficiency of different file systems with micro-CT
ALPCAN GEZER
Diş Hekimliği Uzmanlık
Türkçe
2023
Diş HekimliğiSüleyman Demirel ÜniversitesiEndodonti Ana Bilim Dalı
PROF. DR. BULEM ÜREYEN KAYA
- Farklı giriş kavitesi tasarımlarının preparasyon etkinliği ve transportasyon oluşumu üzerine etkisinin bilgisayarlı mikrotomografi (mikro-BT) ile değerlendirilmesi
Evaluation of the effect of different access cavity designs on preparation efficiency and transportation formation with computerized microtomography (Micro-CT )
BERFU AYDANUR POLAT
Diş Hekimliği Uzmanlık
Türkçe
2023
Diş HekimliğiHacettepe ÜniversitesiEndodonti Ana Bilim Dalı
PROF. DR. ZELİHA YILMAZ
- Aynı ısıl işlem ile standardize edilmiş farklı kesitli Nİ-Tİ döner eğelerinin kanal şekillendirmelerinin mikro bilgisayarlı tomografi ile değerlendirilmesi
Evaluation of canal shaping of Nİ-Tİ rotary files with different sections standardized with the same HEAT treatment by micro computed tomography
BÜŞRA NUR ÇETİN
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiAtatürk ÜniversitesiEndodonti Ana Bilim Dalı
DR. ÖĞR. ÜYESİ HALİT ALADAĞ
- Farklı endodontik giriş kavitesi tasarımlarının apikalden çıkan debris miktarı üzerine etkisi
The effect of different endodontic access cavity designs on the amount of apically extruded debris
MELTEM MEMİŞ
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiAtatürk ÜniversitesiEndodonti Ana Bilim Dalı
DOÇ. DR. ERTUĞRUL KARATAŞ
- Farklı giriş kavitesi tasarımlarının işlem sonrası ağrı ve bakteri yükü üzerindeki etkisi: Randomize kontrollü klinik bir çalışma
The effect of different entrance cavity designs on post-procedural pain and bacterial load: A randomised controlled clinical study
MİRZE MUHAMMET ÖZEN
Diş Hekimliği Uzmanlık
Türkçe
2024
Diş HekimliğiAtatürk ÜniversitesiEndodonti Ana Bilim Dalı
PROF. DR. ERTUĞRUL KARATAŞ