İki farklı sabit retainer telinin stabilite ve periodontal sağlık açısından karşılaştırılması
A comparison of two different fixed retainer wires in terms of stability and periodontal health
- Tez No: 903609
- Danışmanlar: DOÇ. DR. PAMİR MERİÇ
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Mandibula anterior, periodontal dokular, relaps, stabilite, Mandibular anterior, periodontal tissues, relapse, stability
- Yıl: 2024
- Dil: Türkçe
- Üniversite: Trakya Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 87
Özet
Bu çalışma, farklı sabit pekiştirme apareylerini; relapsın daha çok görüldüğü mandibula anterior bölgede stabilite ve periodontal dokular üzerindeki etkisi açısından karşılaştırmak ve literatüre katkı sağlamak amacıyla yapılmıştır. Bu çalışma için Trakya Üniversitesi Diş Hekimliği Fakültesi Ortodonti Anabilim Dalı'nda tedavi görmüş toplamda 40 bireye aynı hekim tarafından 0,0215 inç çok sarımlı paslanmaz çelik pekiştirme teli (G&H Orthodontics, Franklin, ABD) (20 kişi) ve 0,0195 inç çok sarımlı dead soft pekiştirme teli (Ormco, 1332 South Lone Hill Avenue, Glendora, CA) (20 kişi) uygulanmıştır. Bireyler gruplara randomizasyonla seçilmiştir. Stabilite karşılaştırmaları için bireylerden tedavi öncesi (T0), tedavi bitimi (T1), tedavi bitiminden 3 ay sonra (T2), tedavi bitimden 6 ay sonra (T3) ve tedavi bitimden 1 yıl sonra (T4) olacak şekilde alçı model kayıtları alınmıştır. Alınan kayıtlardan interkanin mesafe, Little Çapraşıklık İndeksi, ark uzunluğu ölçümleri yapılmıştır. Model ölçümleri Orthomodel programında dijital olarak aynı hekim tarafından yapılmıştır. Periodontal değerlendirme için ölçümler pekiştirme aşamasındaki kontrol seanslarında (T1, T2, T3, T4) rutin muayenede yapılmıştır. Gingival indeks, plak indeksi, cep derinliği, sondlamada kanama varlığı ve retainer üstünde plak indeksi skorları ölçülmüş ve skorlar kaydedilmiştir. İki retainer grubunun periodontal dokular üzerindeki etkisi incelendiğinde, olumsuz bir etki gözlemlenmemiş ve kendi oral hijyenini idame ettirebilen bireylerde kullanımlarında bir sakınca görülmemiştir. Stabilite konusunda, mandibular ark düzensizliğinin bir yıllık değişiminde 0,0195 inç dead soft retainer grubunda istatistiksel olarak daha fazla relaps görülmüştür. Klinik olarak ve hasta memnuniyeti açısından belirgin bir fark görülmese de stabilite konusunda karşılaştırmalı çalışmalara ihtiyaç duyulmaktadır.
Özet (Çeviri)
This study was conducted to compare the effects of different fixed retention appliances on stability and periodontal tissues, particularly in the mandibular anterior region, where the relapse is more commonly observed, and to contribute to the literature. A total of 40 individuals who received treatment at the Department of Orthodontics, Faculty of Dentistry, Trakya University were included in this study. Two types of retainers were applied by the same clinician: 0.0215-inch multistrand stainless steel retainer wire (G&H Orthodontics, Franklin, ABD) (20 individuals) and 0.0195-inch multistrand dead soft retainer wire (Respond;Ormco, 1332 South Lone Hill Avenue, Glendora, CA) (20 individuals). The individuals were randomly assigned to groups. To compare stability, plaster model records were obtained from the individuals at five time points: before treatment (T0), at the end of treatment (T1), three months post-treatment (T2), six months post-treatment (T3), and one year post-treatment (T4). Measurements of intercanine distance, Little's irregularity index, and arch length were taken from these records. The model measurements were digitally performed by the same clinician using the Orthomodel software. For periodontal evaluation, measurements were taken during routine examinations at retention phase control sessions (T1, T2, T3, T4). Gingival index, plaque index, pocket depth, bleeding on probing, and plaque index scores on the retainer were recorded. When examining the effects of the two retainer groups on periodontal tissues, no adverse effects were observed, and the use of retainers was found to be safe in individuals who could maintain their own oral hygiene. In terms of stability, a statistically significant higher relapse was observed in the 0.0195-inch dead soft retainer group over the one-year period regarding mandibular arch irregularity. Although no significant differences were observed clinically or in terms of patient satisfaction, further comparative studies on stability are needed.
Benzer Tezler
- Çeşitli sabit pekiştirme aparey ve protokollerinin 3 boyutlu olarak karşılaştırılması
Various fixed retention appliences and protocols comparison in 3 dimensions
ÖZGE DENİZ
Doktora
Türkçe
2022
Diş Hekimliğiİstanbul Okan ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. DR. AHMET NEJAT ERVERDİ
- İki farklı lingual retainer uygulamasının klinik etkinliğinin değerlendirilmesi
Evaluation of clinical effectiveness of two different lingual retainers application
FİRDEVS GÜNAY
Diş Hekimliği Uzmanlık
Türkçe
2017
Diş HekimliğiOndokuz Mayıs ÜniversitesiOrtodonti Ana Bilim Dalı
YRD. DOÇ. DR. ABDULLAH ALPER ÖZ
- Farklı tip sabit lingual pekiştirme aygıtlarının korozyon dirençlerinin laboratuvar ortamında değerlendirilmesi
Evaluation of corrosion resistance of different fixed retention appliances in a laboratory environment
BÜŞRA KUMRULAR
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiZonguldak Bülent Ecevit ÜniversitesiOrtodonti Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ORHAN ÇİÇEK
- İki farklı sabit pekiştirme telinin alt kesici çapraşıklığına ve gingival dokulara etkilerinin incelenmesi
Comparison of the effects of two different fixed retainer wires on lower incisor crowding and gingival tissues
MELİS SEKİ YURDAKUL
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiTrakya ÜniversitesiOrtodonti Ana Bilim Dalı
DR. ÖĞR. ÜYESİ PAMİR MERİÇ
- Alternative control strategies for an electromechanical active suspension system
Bir elektromekanik aktif süspansiyon sistemi için alternatif kontrol stratejileri
SEVSEL GAMZE KABİL
Yüksek Lisans
İngilizce
2012
Makine Mühendisliğiİstanbul Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. ÖZGEN AKALIN