Anterior süt dişlerinde prefabrik zirkonya kuron simantasyonunda siman seçiminin mikrosızıntı ve renklenme üzerindeki etkisi: In Vitro inceleme
The effect of cement selection on microleakage and staining in prefabricated zirconia crown cementation on anterior primaryteeth: An In Vitro study
- Tez No: 926714
- Danışmanlar: DOÇ. DR. EMİNE KAYA
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Çocuk diş hekimliği, Bioactive Cement, Discoloration, Microleakage, Spectrophotometry, Zirconia, Pediatric dentistry
- Yıl: 2025
- Dil: Türkçe
- Üniversite: Sağlık Bilimleri Üniversitesi
- Enstitü: Hamidiye Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Çocuk Diş Hekimliği Ana Bilim Dalı
- Bilim Dalı: Çocuk Diş Hekimliği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışma, iki farklı marka prefabrik zirkonya kuronun üç farklı siman ile simante edilmesi sonrası termal yaşlandırmanın renk stabilitesi ve mikrosızıntı üzerine etkisini değerlendirmeyi amaçlamaktadır. Gereç ve Yöntem: Toplam 48 çekilmiş süt anterior dişi iki gruba ayrıldı: NuSmile® (Houston, TX, ABD) ve ProfZrCrown® (İstanbul, Türkiye). Her grup, siman türüne göre üç alt gruba ayrıldı: Cam İyonomer Siman (CİS), Rezin Modifiye Cam İyonomer Siman (RMCİS) ve ACTIVA Biyoaktif Siman. Numuneler 5000 termal döngüye (5°C–55°C, 10 sn bekleme süresi) tabi tutulduktan sonra renk stabilitesi spektrofotometre (VITA Easyshade Compact, Almanya) ile değerlendirildi. Mikrosızıntı, metilen mavisi boya penetrasyonu ve stereo mikroskop analizi ile incelendi. Bulgular: NuSmile kuronlar, ProfZrCrown kuronlara kıyasla daha fazla renk değişimi gösterdi (p <0,05). ProfZrCrown kuronlar, klinik olarak kabul edilebilir renk stabilitesini (ΔE <2,7) korudu. CİS, NuSmile kuronlarda daha fazla renklenmeye neden olurken, ACTIVA ProfZrCrown kuronlarda en yüksek renk değişimini oluşturdu (p <0,05). Mikrosızıntı açısından iki marka arasında anlamlı fark bulunmazken, NuSmile kuronlarda RMCİS en düşük, ACTIVA ise en yüksek mikrosızıntıyı gösterdi. Kanin dişlerde siman türünün mikrosızıntıya etkisi anlamlı bulunmazken, santral kesici dişlerde RMCİS en iyi marjinal sızdırmazlığı (p = 0,019), CİS ise en yüksek sızıntıyı gösterdi. Sonuç: RMCİS mikrosızıntıyı en aza indirmede en etkili siman olarak belirlenirken, ProfZrCrown kuronlar daha iyi renk stabilitesi sağladığı tespit edildi. Uzun vadeli estetik ve fonksiyonel başarı için uygun kuron-siman kombinasyonunun seçimi önemlidir. Bulguların klinik olarak doğrulanması için ileri çalışmalar gerekmektedir.
Özet (Çeviri)
Aim: This study aimed to evaluate the effects of different cements on microleakage and discoloration in two brands of prefabricated zirconia crowns for anterior primary teeth after artificial aging. Materials and Methods: Forty-eight extracted primary anterior teeth were divided into two groups: NuSmile® and ProfZrCrown®. Each group was further subdivided based on the cement used: Fuji One (GIC), FujiCem Evolve (RMGIC), and ACTIVA Bioactive Cement. The samples underwent 5000 thermal cycles (5°C–55°C, 10 s dwell time), and color stability was assessed using a spectrophotometer (VITA Easyshade Compact, Germany). Microleakage was evaluated through methylene blue dye penetration and stereomicroscope analysis. Results: NuSmile crowns exhibited significantly greater color change than ProfZrCrown crowns (p <0.05), which maintained clinically acceptable color stability (ΔE <2.7). GIC caused more discoloration in NuSmile crowns, while ACTIVA resulted in the highest color change in ProfZrCrown crowns (p <0.05). No significant difference in microleakage was found between the crown brands. In NuSmile crowns, RMGIC showed the lowest microleakage, while ACTIVA had the highest. Cement type had no significant effect on microleakage in canines, but RMGIC provided the best marginal seal in central incisors (p = 0.019), whereas GIC showed the highest leakage. Conclusion: RMGIC was the most effective cement in reducing microleakage, while ProfZrCrown crowns provided superior color stability. Selecting an appropriate crown-cement combination is essential for long-term success in pediatric dentistry. Further clinical studies are needed to validate these findings.
Benzer Tezler
- Prefabrı̇ke zirkonya kronlarda kullanılan farklı simantasyon materyallerı̇nin mikrosızıntısının değerlendirilmesi
Evaluation of microleakage for different cementation materials used in prefabricated zirconia crowns
BEYZA ECEM ALKAÇ
- Ön grup süt dişlerinde kullanılan polimerglas ve kompozit kuronların bazı mekanik testler ve klinik yönden değerlendirilmesi
Evaluation of polymerglass and composite crowns applied to anterior group primary teeth with some mechanical tests and from clinical angle
SEVGİ KAMBEK
- Genel anestezi altında yapılan endodontik tedavilerin klinik başarı ve radyografik sonuçlarının retrospektif analizi
Retrospective evaluation of the clinical and radiographic success of endodontic treatments performed on primary teeth under general anesthesia
EMİNE BÜŞRA YAPAKLI
- Süt dişlerinde kullanılan prefabrike zirkonyum kronların mikrosızıntı ve kırılma dayanımlarının değerlendirilmesi
Evaluation of microleakage and fracture resistance of prefabricated zirconium crowns used on primary teeth
NAZİLE PEHLİVAN
- Süt keser dişlerin ı̇ndirekt restorasyonlarının ı̇n vitro ı̇ncelenmesi
In vitro investigation of indirect restorations for primary anterior teeth
MURAT BÜYÜKSEFİL