71Ga, 75As, 115In, 152Sm, 158Gd, 164Dy, 170Er, 179Hf izotoplarının (n,?) tepkimeleri için etkin rezonans enerjilerinin çift monitör yöntemi ile belirlenmesi
Experimental determination of effective resonance energies for the (n,?) reactions of 71Ga, 75As, 115In, 152Sm, 158Gd, 164Dy, 170Er, 179Hf by dual monitor method
- Tez No: 233703
- Danışmanlar: DOÇ. DR. HALUK YÜCEL, PROF. DR. MUSTAFA TAN
- Tez Türü: Doktora
- Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2008
- Dil: Türkçe
- Üniversite: Gazi Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Fizik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 190
Özet
Bu tezde, epitermal nötron spektrumu bölgesinde gözlenen çok sayıdaki rezonans enerjisi yerine kullanılabilecek etkin bir rezonans enerjisinin deneysel olarak belirlenmesi amaçlanmıştır. Etkin rezonans enerjilerinin deneysel olarak belirlenmesinde, üstün rezonans özellikleri olan 55Mn ve 98Mo izotoplarının, çift monitör olarak kullanılması önerilmiştir. Önerilen çift monitör yöntemi ile 71Ga(n,?)72Ga, 75As(n,?)76As, 115In(n,?)116mIn, 152Sm(n,?)153Sm, 158Gd(n,?)159Gd, 164Dy(n,?)165Dy, 170Er(n,?)171Er ve 179Hf(n,?)180mHf tepkimelerinin etkin rezonans enerjileri deneysel olarak belirlenmiştir. Toz halindeki numuneler, 241Am-Be nötron kaynağından (aktivitesi: 3x592 GBq) elde edilen izotropik nötron alanında ışınlanmıştır. Numuneler, termal nötronların etkisine karşı, 1 mm kalınlıklı Cd silindirik kılıf içinde ışınlanmıştır ve elde edilen aktiviteler, p tipi, eş eksenli ve bağıl verimi %120,8 olan bir HPGe dedektörde ölçülmüştür. Gama öz soğurulması (Fg), termal nötron öz soğrulması (Gth) ve epitermal nötron öz soğurulması (Gepi) için gerekli düzeltme faktörleri hesaba katılmıştır. Gerçek eş zamanlı çakışma toplama etkileri (true coincidence summing effect) nedeniyle olabilecek sayım kayıplarının elimine edilmesi veya en aza indirgenmesi için numuneler sayım sırasında, dedektörden 10 cm uzakta tutulmuştur. Deneysel verilerin değerlendirilmesinde, ölçümlerde Cd-oranı karşılaştırma yöntemi kullanılmıştır. İncelenen tepkimelerin Er değerleri, sırasıyla 71Ga(n,?)72Ga için 174±36 eV, 75As(n,?)76As için 112±23 eV, 115In(n,?)116mIn için 1,58±0,33 eV, 152Sm(n,?)153Sm için 8,65±1,80 eV, 158Gd(n,?)159Gd için 49,6±10,4 eV, 164Dy(n,?)165Dy için 225±47 eV, 170Er(n,?)171Er için 129±27 eV ve 179Hf(n,?)180mHf için 17,0±3,5 eV olarak belirlenmiştir. İncelenen izotoplar için literatürde deneysel olarak belirlenen Er değerleri olmadığından ölçülen değerler, güncel rezonans verileri kullanılarak kuramsal yaklaşımlarla hesaplanan Er değerleri ve daha önce hesaplanmış kuramsal değerler ile karşılaştırılmıştır. Çalışma sonucunda, incelenen izotoplar için ölçülen Er ile teorik hesaplamayla elde edilen Er değerleri, %0,6 ile %15 arasında uyuşmaktadır. Ancak, 164Dy(n,?)165Dy için ölçülen değer, eski literatür teorik değerlerinden, %0,4 ile %35 arasında değişen oranda farklıdır. 1/E1+? gerçek epitermal spektrumlarda, Er değerleri elde edilecek diğer analitik nicelikleri önemli derecede etkilediğinden, standartlaştırma çalışmalarının güvenilirliğinin artırılması için diğer izotopların Er değerleri için de deneysel ölçümlerin yapılması gerekmektedir.
Özet (Çeviri)
In this thesis, the main aim is to determine experimentally an average (effective) resonance energy replacing by all resonances lying in epithermal neutron spectra. To do this, a dual monitor (55Mn-98Mo) having favorable resonance properties is suggested. The effective resonance energy (Er) values for the 71Ga(n,?)72Ga, 75As(n,?)76As, 115In(n,?)116mIn, 152Sm(n,?)153Sm, 158Gd(n,?)159Gd, 164Dy(n,?)165Dy, 170Er(n,?)171Er and 179Hf(n,?)180mHf reactions were measured by using Cadmium ratios from a dual monitor (55Mn-98Mo). The powder samples were irradiated in an isotropic neutron field obtained from 241Am-Be neutron sources having an activity of 3x592 GBq. Thermal neutrons were shielded by using 1 mm thick Cd cylindrical box. Thus the induced activities in the samples were measured with a coaxial p-type HPGe detector with a relative efficiency of 120,8%. The necessary correction factors for gamma self-attenuation (Fg), thermal neutron self-shielding (Gth) and resonance neutron self-shielding (Gepi) effects were taken into account. To minimize the true coincidence summing (TCS) events due to possible X and ? ray summing effects, the very small samples were measured at a sample-detector distance of 10 cm. Also the Cd-ratios were determined by using the comparator technique, thus cancelling out the same magnitudes of TCS correction factors. The experimentally determined Er -values were 174±36 eV for 71Ga(n,?)72Ga, 112±23 eV for 75As(n,?)76As, 1,58±0,33 eV for 115In(n,?)116mIn, 8,65±1,80 eV for 152Sm(n,?)153Sm, 49,6±10,4 eV for 158Gd(n,?)159Gd, 225±47 eV for 164Dy(n,?)165Dy, 129±27 eV for 170Er(n,?)171Er and 17,0±3,5 for 179Hf(n,?)180mHf reactions, respectively. Since the experimentally determined Er -values for the 115In, 152Sm, 158Gd, 164Dy, 170Er and 179Hf isotopes are not available in literature, the present experimental results are compared only with those of the newest and earlier theoretically calculated ones. The present experimental results for the Er -values were also theoretically calculated by using the newest resonance data. The results show that the present experimental Er -values for the investigated isotopes agree within 0,6-15% with those of the theoretically calculated ones, except for 164Dy(n,?)165Dy. It is fonnd that the experimental Er -value 164Dy isotope shows a discrepancy varying between 0,4% and 35% from the calculated ones obtained by older and recent resonance data. In literature survey, a wide variation of the available Er -values implies the need for the new experimental determinations of Er -values for other isotopes to obtain more reliable and accurate analytical results. Because the Er -values, especially used in k0 standardization method can affect significiantly other analytical results obtained from a 1/E1+? distribution epithermal neutron spectra existing in real neutron fields
Benzer Tezler
- 71Ga, 74As, 133Cs, 139La, 148Nd, 164Dy, 165Ho ve 186W izotoplarının (n,y) tepkimeleri için termal nötron ve rezonans integral tesir kesitlerinin 55Mn monitörü kullanılarak ölçülmesi
Measurement of thermal neutron and resonance integral cross sections of (n,y) reactions for 71Ga, 74As, 133Cs, 139La, 148Nd, 164Dy, 165Ho and 186W isotopes using single monitor 55Mn
MUSTAFA KARADAĞ
Doktora
Türkçe
2003
Fizik ve Fizik MühendisliğiGazi ÜniversitesiFizik Eğitimi Ana Bilim Dalı
DOÇ. DR. HALUK YÜCEL
- Galyum ürün çekirdeklerinin enerji seviyelerinin ve kalay numunelerinin derişimlerinin fotonükleer reaksiyonlarla belirlenmesi
Determination of the energy levels of gallium's product nuclei and the concentration of tin in tin-containing samples by photonuclear reactions
ALP CESUR
Yüksek Lisans
Türkçe
2015
Fizik ve Fizik MühendisliğiAkdeniz ÜniversitesiFizik Ana Bilim Dalı
YRD. DOÇ. DR. MESUT KARAKOÇ
- Lipaz enziminin magnetik nanopartiküllere farklı ara kollar üzerinden immobilizasyonu ve karakterizasyonu
Immobilization and characterization of enzyme on magnetic nanoparticles through different intermediate arms
MÜGE ŞENGÜL
- Üreaz enziminin magnetik nanopartiküllere farklı ara kollar üzerinden immobilizasyonu ve karakterizasyonu
Immobilization and characterization of urease enzyme over magnetic nanoparticles through different intermediate arms
NURİ GÜLEŞCİ