Farklı seviyelerde ozon kullanımının Erzurum ili içme suyunun bazı fiziksel, kimyasal ve mikrobiyolojik özellikleri üzerine etkisi
Different level usage of ozone effect on some physical, chemical and microbiological quality of Erzurum city?s drinking water
- Tez No: 284372
- Danışmanlar: DOÇ. DR. MUSTAFA GÜRSES
- Tez Türü: Yüksek Lisans
- Konular: Gıda Mühendisliği, Food Engineering
- Anahtar Kelimeler: Ozon, Ozone
- Yıl: 2011
- Dil: Türkçe
- Üniversite: Atatürk Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Gıda Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmada Erzurum İli Arıtma Tesisine gelen suya 12 ay boyunca farklı seviyelerde ozon uygulanmış ve ozonun suyun bazı fiziksel, kimyasal ve mikrobiyolojik özellikleri üzerine etkisi araştırılmıştır.Toplam 12 aylık periyotta ham suda ortalama toplam koliform sayısı 2,35 log kob/100ml, fekal koliform sayısı 0,57 log kob/100ml, Clostridium perfingens (Cl. perfingens) sayısı 2,03 log kob/50ml, pH 7,36, elektriksel iletkenlik 207 µS/cm, renk 19,60 Pt/Co, bulanıklık 7,21 NTU, nitrat 1,39 ppm, nitrit 0,007 ppm, amonyum 0,44 ppm, demir 0,29 ppm ve mangan miktarı 177 ppb olarak bulunmuştur. Ozonlama sonrasında hiçbir örnekte toplam koliform, fekal koliform ve Cl. Perfingens'e rastlanmamıştır. Bununla birlikte,3 mg/L ozon düzeyinde saptanan ortalama pH 7,29, elektriksel iletkenlik 224 µS/cm, renk 12,37 Pt/Co, bulanıklık 6,78 NTU, nitrat 1,83 ppm, nitrit 0,004 ppm, amonyum 0,36 ppm, demir 0,058 ppm ve mangan 154 ppb değerlerinin içme suyu kalitesi bakımından diğer seviyelerden daha uygun olduğu sonucuna varılmıştır.En düşük ozon seviyesi 1 mg/L tüm mikroorganizma gruplarını öldürmeye yeterli gelmiş; ozon miktarındaki artış iletkenlik ve nitrat seviyelerinde artışa, pH, renk, bulanıklık, demir, mangan, amonyum ve nitrit miktarlarında ise azalmaya yol açmıştır.
Özet (Çeviri)
In this study, different levels of ozone have been used in research on the water that runs into the purification plant of Erzurum City and on ozone?s effect on some physical, chemical and microbiological quality of the water during the 12 month study.The following was found in the untreated water: total coliform count was 2.35 log kob/100ml, fecal coliform count was 0.57 log kob/100 ml, Clostridium perfingens count was 2.03 log kob/50 ml, pH 7.36, electrical conductivity was 207 µS/cm, the color was 19.60 Pt/Co, cloudiness was 7.21 NTU, nitrate was 1.39 ppm, nirite was 0.007 ppm, ammonium was 0.44 ppm, iron was 0.29 ppm and manganese was 177 ppb. After the ozonize proccess no coliform, fecal coliform or Cl. perfingens were detected. However, at 3 mg/L ozon level the following averages were detected: pH 7.29, electrical conductivity 224 µS/cm, the color 12.37 Pt/Co, cloudiness 6.78 NTU, nitrate 1.83 ppm, nitrite 0.004 ppm, ammonium 0.36 ppm, iron 0.058 ppm and manganese 154 ppb. The results of the 3 mg/L of ozone indicated a more sutable effect on the water quality than other levels as a result of the rates. The minimum level of ozone was enough to kill all of the microorganisms. Increasing levels of ozone boosted the level of conductivity and nitrate, and decreased the level of pH, amount of color, cloudiness and the levels of iron, manganese, ammonium and nitrate.
Benzer Tezler
- Deri endüstrisi arıtılmış atıksularındaki KOİ'nin ozon oksidasyonu ile giderimi
COD removal in biological treatment effluent of tannery wastewater by ozone oxidation
ZAİM BERKER YELMEZ
- Evsel koşullarda kirlenmiş olan suların tekrar kullanılabilirliği için farklı dezenfeksiyon yöntemlerinin incelenmesi
The investigation of different disinfection methods for recovery of household greywater
PERVİN SAYGIN
- Evaluating environmental effects of different anaerobic wastewater treatment systems by using LCA approach
Farklı anaerobik atıksu arıtma sistemlerinin çevresel etkilerinin LCA yaklaşımı ile değerlendirilmesi
MERVE YILMAZ
- Yüksek doz klordioksit uygulanan levreklerde (Dicentrarchus labrax L., 1758) toksik patolojik bulguların araştırılması
Investigation of toxic pathological findings in sea bass (dicentrarchus labrax l., 1758) applied with high dose chlorine dioxide
EDA VURAL
- Tam elektrikli araçlarda pil yangınları ve etkin söndürme sistemlerinin incelenmesi
An investigation of battery fires in fully electric vehicles and effective suppression systems
ONUR MAMMACIOĞLU